Radio-Frequency Plasma Thawer
射频血浆解冻仪
- SKU PLT-0003
- Plasma Thawers
- CE (to be confirmed)
- ISO 13485 (to be confirmed)
- IEC 60601-1-2 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Heating method | Radio-frequency or microwave, volumetric |
|---|---|
| Thaw time (250 mL FFP) | approx. 3–10 min |
| Final temperature | ≤ 37 °C |
| Capacity | 1–4 bags |
| Temperature monitoring | Fiber-optic or IR sensors |
| Programs | FFP, cryoprecipitate, custom |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-010
What is the Radio-Frequency Plasma Thawer?
A radio-frequency plasma thawer heats frozen plasma directly with electromagnetic energy, thawing a unit in about 3–10 minutes. It suits emergency departments, trauma centers and blood banks that need plasma quickly for massive transfusion protocols.
What is the Radio-Frequency Plasma Thawer?
A radio-frequency plasma thawer heats frozen plasma directly with electromagnetic energy, thawing a unit in about 3–10 minutes. It suits emergency departments, trauma centers and blood banks that need plasma quickly for massive transfusion protocols.
Overview
The RF thawer places the bag between electrodes or inside a cavity and applies radio-frequency or microwave energy that heats the plasma volumetrically. Because heat is generated within the product rather than transferred through the bag wall, thawing is much faster than baths. Temperature is monitored by sensors, and the controller modulates power and uses rocking or cooling to prevent hot spots. Cycle time for a 250 mL unit is typically 3 to 10 minutes. Capacity is usually one to four bags. The equipment is more complex and costly, and requires careful validation so that no region exceeds 37 °C and proteins are not denatured. Shielding meets electromagnetic safety limits, and display and alarms show cycle status and faults.
How does it work?
Thawing transfers heat into a frozen bag while keeping plasma below about 37 °C, because higher temperatures denature coagulation factors. Water-bath thawers circulate water at 35–37 °C around the bag, using a heater, pump and thermostat, and typically take 20 to 30 minutes. Dry thawers heat plates or chambers with shaking or rocking so the bag exchanges heat without contact with water. Radio-frequency thawers apply electromagnetic energy to heat the plasma directly, cutting time to a few minutes. Temperature sensors, often in the bath or in a reference bag, feed a controller that limits overshoot and raises alarms. Agitation improves heat transfer and helps dissolve cryoprecipitate. Overwrap bags protect ports from contamination in water baths.
What are the key features?
- Volumetric RF heating thaws a unit in about 3–10 minutes
- Power modulation to avoid hot spots above 37 °C
- Rocking or cooling to equalize temperature
- Electromagnetic shielding meeting safety limits
- Cycle display with alarms for faults
- Programs for plasma and cryoprecipitate units
What are the technical specifications?
A typical radio-frequency plasma thawer configuration offers heating method of Radio-frequency or microwave, volumetric, thaw time (250 mL FFP) of approx. 3–10 min, final temperature of ≤ 37 °C, capacity of 1–4 bags, temperature monitoring of Fiber-optic or IR sensors and programs of FFP, cryoprecipitate, custom. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Radio-Frequency Plasma Thawer is used in massive transfusion protocols, trauma centers, emergency departments and operating theater plasma supply. Across the wider Plasma Thawers class, laboratories also deploy it for fresh frozen plasma thawing before transfusion, cryoprecipitate thawing and massive transfusion protocols.
Which standards and certifications apply?
Relevant standards and methods include Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-010, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and IEC 60601-1-2 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Validate each thawer with the bag types used, recording thaw time and final temperature. Calibrate temperature sensors at least annually and test alarms routinely. Water baths need regular draining, disinfection and water quality control to avoid bacterial growth, and overwraps should be used. Dry thawers need plates and chambers cleaned after leaks. Do not thaw above the limit, and use thawed plasma within the time defined by local policy. Keep records of each thaw for traceability. Follow electrical safety tests and, for RF units, electromagnetic safety rules.
How do I select the right Radio-Frequency Plasma Thawer?
Choose RF thawing when minutes matter and plasma demand is urgent and frequent. Specify capacity, validated bag types, program list and electromagnetic shielding. Ask for thaw-profile data showing no region exceeds 37 °C. Water or dry units are adequate for planned use.
How does it compare with other Plasma Thawers variants?
Choose by speed, capacity and contamination control. Water baths are economical and familiar but require water management and overwraps. Dry thawers avoid water, simplifying hygiene and port protection. RF thawers are fastest, useful where urgent plasma is frequent, but cost more. Match capacity to peak demand, for example one to four bags at the bedside or eight to sixteen in a blood bank. Check temperature accuracy, overshoot protection, bag size compatibility including cryoprecipitate and pooled bags, and the alarm and record features needed for audits. Noise, cleaning and footprint matter for operating-theater use.
Full specifications
| Heating method | Radio-frequency or microwave, volumetric |
|---|---|
| Thaw time (250 mL FFP) | approx. 3–10 min |
| Final temperature | ≤ 37 °C |
| Capacity | 1–4 bags |
| Temperature monitoring | Fiber-optic or IR sensors |
| Programs | FFP, cryoprecipitate, custom |
| Alarms | Over-temperature, bag missing, fault |
| Shielding | Compliant with EMC limits |
| Dimensions (W×D×H) | approx. 400 × 450 × 350 mm |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Massive transfusion protocols
- Trauma centers
- Emergency departments
- Operating theater plasma supply
Key features
- Volumetric RF heating thaws a unit in about 3–10 minutes
- Power modulation to avoid hot spots above 37 °C
- Rocking or cooling to equalize temperature
- Electromagnetic shielding meeting safety limits
- Cycle display with alarms for faults
- Programs for plasma and cryoprecipitate units
Frequently asked questions about Radio-Frequency Plasma Thawer
When properly validated, no: controlled power and monitoring keep the plasma at or below 37 °C, and studies on such devices report acceptable coagulation factor activity. Validate on your bag types and follow the manufacturer's cycle settings exactly.
Energy is absorbed throughout the plasma volume instead of conducted through bag walls and ice from the outside. This bypasses the slow heat-conduction step, so a 250 mL unit thaws in minutes rather than tens of minutes.
Only those the manufacturer has validated. Bag shape, fill volume and plastic type affect energy absorption, so cycle programs are tied to specific bag formats. Ask for a validation list and test your own bags.
A water-bath thawer usually needs 20–30 minutes for a 250 mL unit, dry thawers take 15–30 minutes depending on design, and radio-frequency thawers can do it in roughly 3–10 minutes. Times depend on bag size, frozen temperature and agitation.
Typically 30–37 °C, with 37 °C as the usual upper limit. Higher temperatures denature coagulation factors, so thawers include sensors and alarms to prevent overheating and a controlled warm-up profile.
It can be if water quality is controlled, bags are overwrapped and the bath is disinfected and drained on schedule. Contaminated water is a recognized risk, so many centers prefer dry or overwrapped methods to protect bag ports.