Circulating Water Bath Plasma Thawer
循环水浴式血浆解冻仪
- SKU PLT-0001
- Plasma Thawers
- CE (to be confirmed)
- ISO 13485 (to be confirmed)
- IEC 61010-2-010 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Thaw temperature | 35–37 °C |
|---|---|
| Temperature accuracy | ±0.5 °C |
| Thaw time (250 mL FFP) | approx. 20–30 min |
| Capacity | 4–8 bags |
| Tank volume | 10–30 L |
| Heater power | approx. 1000–1500 W |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-010
What is the Circulating Water Bath Plasma Thawer?
A circulating water bath plasma thawer heats and pumps water at 35–37 °C around sealed plasma bags, thawing units in roughly 20–30 minutes. It suits blood banks and hospital transfusion services that want a simple, proven method with moderate capacity and low running cost.
What is the Circulating Water Bath Plasma Thawer?
A circulating water bath plasma thawer heats and pumps water at 35–37 °C around sealed plasma bags, thawing units in roughly 20–30 minutes. It suits blood banks and hospital transfusion services that want a simple, proven method with moderate capacity and low running cost.
Overview
The thawer has a stainless steel tank, an immersion heater, a circulation pump and a microprocessor thermostat with an independent over-temperature cutout. Water flows along the bags held in racks, so heat transfer is uniform. Some models rock the rack to improve transfer and speed cryoprecipitate dissolution. Tank volume is usually 10 to 30 L and capacity four to eight plasma bags. Setpoint is typically 37 °C with accuracy of ±0.5 °C. The system includes low-water and over-temperature alarms. Bags must be placed in overwraps to keep ports dry, and the tank is drained and disinfected regularly. Running cost is low, and the design is simple to service, but water quality management is essential for hygiene.
How does it work?
Thawing transfers heat into a frozen bag while keeping plasma below about 37 °C, because higher temperatures denature coagulation factors. Water-bath thawers circulate water at 35–37 °C around the bag, using a heater, pump and thermostat, and typically take 20 to 30 minutes. Dry thawers heat plates or chambers with shaking or rocking so the bag exchanges heat without contact with water. Radio-frequency thawers apply electromagnetic energy to heat the plasma directly, cutting time to a few minutes. Temperature sensors, often in the bath or in a reference bag, feed a controller that limits overshoot and raises alarms. Agitation improves heat transfer and helps dissolve cryoprecipitate. Overwrap bags protect ports from contamination in water baths.
What are the key features?
- Circulating water at 35–37 °C for uniform heating
- Independent over-temperature cutout protects plasma
- Rack holds 4–8 bags with optional rocking
- Low-water and high-temperature alarms
- Stainless steel tank with drain valve
- Low running cost and simple service
What are the technical specifications?
A typical circulating water bath plasma thawer configuration offers thaw temperature of 35–37 °C, temperature accuracy of ±0.5 °C, thaw time (250 mL FFP) of approx. 20–30 min, capacity of 4–8 bags, tank volume of 10–30 L and heater power of approx. 1000–1500 W. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Circulating Water Bath Plasma Thawer is used in hospital transfusion services, blood bank plasma issue, cryoprecipitate thawing and emergency plasma preparation. Across the wider Plasma Thawers class, laboratories also deploy it for fresh frozen plasma thawing before transfusion, cryoprecipitate thawing and massive transfusion protocols.
Which standards and certifications apply?
Relevant standards and methods include Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-010, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and IEC 61010-2-010 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Validate each thawer with the bag types used, recording thaw time and final temperature. Calibrate temperature sensors at least annually and test alarms routinely. Water baths need regular draining, disinfection and water quality control to avoid bacterial growth, and overwraps should be used. Dry thawers need plates and chambers cleaned after leaks. Do not thaw above the limit, and use thawed plasma within the time defined by local policy. Keep records of each thaw for traceability. Follow electrical safety tests and, for RF units, electromagnetic safety rules.
How do I select the right Circulating Water Bath Plasma Thawer?
Choose a circulating water bath for moderate volumes where you can manage water hygiene and overwraps. Specify bag capacity, rocking option, setpoint accuracy, alarms and tank size. If water handling is a concern, consider a dry thawer, and for urgent supply, radio-frequency models.
How does it compare with other Plasma Thawers variants?
Choose by speed, capacity and contamination control. Water baths are economical and familiar but require water management and overwraps. Dry thawers avoid water, simplifying hygiene and port protection. RF thawers are fastest, useful where urgent plasma is frequent, but cost more. Match capacity to peak demand, for example one to four bags at the bedside or eight to sixteen in a blood bank. Check temperature accuracy, overshoot protection, bag size compatibility including cryoprecipitate and pooled bags, and the alarm and record features needed for audits. Noise, cleaning and footprint matter for operating-theater use.
Full specifications
| Thaw temperature | 35–37 °C |
|---|---|
| Temperature accuracy | ±0.5 °C |
| Thaw time (250 mL FFP) | approx. 20–30 min |
| Capacity | 4–8 bags |
| Tank volume | 10–30 L |
| Heater power | approx. 1000–1500 W |
| Agitation | Circulation pump, optional rocking |
| Safety | Independent over-temperature cutout |
| Alarms | Low water, high temperature, sensor fault |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Hospital transfusion services
- Blood bank plasma issue
- Cryoprecipitate thawing
- Emergency plasma preparation
Key features
- Circulating water at 35–37 °C for uniform heating
- Independent over-temperature cutout protects plasma
- Rack holds 4–8 bags with optional rocking
- Low-water and high-temperature alarms
- Stainless steel tank with drain valve
- Low running cost and simple service
Frequently asked questions about Circulating Water Bath Plasma Thawer
Follow the manufacturer and local infection control policy, but many sites drain, clean and refill at least daily or weekly and disinfect the tank on a schedule. Use distilled or treated water where advised to limit scale and microbial growth.
Overwraps keep the bag ports dry so that contaminated water cannot contact the access sites, which reduces infection risk. They also contain leaks from damaged bags and keep labels readable during thawing.
Yes, typically at 30–37 °C for 10–15 minutes with gentle agitation so the cryoprecipitate dissolves without overheating. Use a thawer that supports the smaller bag sizes and confirm the procedure with your transfusion service.
A water-bath thawer usually needs 20–30 minutes for a 250 mL unit, dry thawers take 15–30 minutes depending on design, and radio-frequency thawers can do it in roughly 3–10 minutes. Times depend on bag size, frozen temperature and agitation.
Typically 30–37 °C, with 37 °C as the usual upper limit. Higher temperatures denature coagulation factors, so thawers include sensors and alarms to prevent overheating and a controlled warm-up profile.
It can be if water quality is controlled, bags are overwrapped and the bath is disinfected and drained on schedule. Contaminated water is a recognized risk, so many centers prefer dry or overwrapped methods to protect bag ports.
Related models