Automatic Polarimeter for Pharmaceutical Analysis

药品分析自动旋光仪

  • SKU PHA-0005
  • Pharmaceutical Analyzers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measuring range±90°
Resolution0.001°
Accuracyabout ±0.01°
Wavelength589 nm standard, others optional
Temperature control15–40 °C, ±0.2 °C
Cell path length100 mm or 200 mm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <856>, USP <858>, USP <541>

What is the Automatic Polarimeter for Pharmaceutical Analysis?

An automatic polarimeter measures optical rotation to identify and assay chiral drug substances, and is frequently used for sugars and optically active compounds. It provides a specific, pharmacopoeial measurement for identity and purity.

What is the Automatic Polarimeter for Pharmaceutical Analysis?

An automatic polarimeter measures optical rotation to identify and assay chiral drug substances, and is frequently used for sugars and optically active compounds. It provides a specific, pharmacopoeial measurement for identity and purity.

Overview

A polarimeter passes plane-polarised light through a sample and measures the angle by which the plane of polarisation is rotated. Optical rotation depends on the substance, its concentration, path length, temperature and wavelength, so measurements are reported as specific rotation at a stated temperature and wavelength, usually sodium D line at 589 nm and 20 °C. Automatic instruments use a photodetector and a servomotor or Faraday modulator to find the null point, giving repeatable readings without visual judgement. Pharmaceutical uses include identity and assay of chiral drugs, glucose and other sugars, and the control of racemisation during synthesis. A temperature-controlled sample cell is important because rotation changes with temperature, and the cell path length, commonly 100 mm, must be known and recorded.

How does it work?

Pharmaceutical analyzers apply spectroscopic, electrochemical or physical measurement principles to drug samples. Near-infrared instruments measure the absorption of light from about 780 to 2500 nm by overtone and combination vibrations of molecular bonds, which gives a fingerprint suitable for identification through packaging. Raman analyzers measure inelastic light scattering and are sensitive to molecular symmetry and crystal form. Potentiometric titrators add reagent until a sensor detects the equivalence point, so the consumed volume gives content. Laser diffraction measures the angular scatter of laser light as particles pass, which is converted to a size distribution. Polarimeters measure optical rotation, a specific property of chiral drug substances. Calibration or verification with reference standards is needed for each technique.

What are the key features?

  • Photoelectric detection of optical rotation
  • Servomotor or Faraday null-point system
  • Temperature-controlled sample cell
  • Specific rotation at 589 nm and 20 °C
  • Digital readout with storage of results
  • Suited to chiral drugs and sugars

What are the technical specifications?

A typical automatic polarimeter for pharmaceutical analysis configuration offers measuring range of ±90°, resolution of 0.001°, accuracy of about ±0.01°, wavelength of 589 nm standard, others optional, temperature control of 15–40 °C, ±0.2 °C and cell path length of 100 mm or 200 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automatic Polarimeter for Pharmaceutical Analysis is used in chiral drug identity and assay, sugar content determination, racemisation monitoring and raw material quality control. Across the wider Pharmaceutical Analyzers class, laboratories also deploy it for raw material identification at goods-in, drug substance assay and excipient quality control.

Which standards and certifications apply?

Relevant standards and methods include USP <856>, USP <858>, USP <541>, USP <429>, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers on a stable bench away from vibration, direct sun and strong draughts, and let them warm up before use. Verify performance with reference standards on a defined schedule, not only when a supplier service visit occurs, and record the results. Keep sample surfaces clean and use fresh consumables such as electrode filling solution and membranes. For near-infrared and Raman, maintain the reference library and re-qualify after any lamp or laser change. Operate under a validated procedure with trained staff, and retain raw spectra or titration curves because regulators may ask for them. Dispose of waste reagents according to local regulations.

How do I select the right Automatic Polarimeter for Pharmaceutical Analysis?

Choose an automatic polarimeter when the monograph specifies optical rotation for identity or assay. Confirm measuring range, resolution, temperature control, cell path length and wavelength. Verify the instrument with a certified standard such as quartz or sucrose solution, and control cell temperature during measurement.

How does it compare with other Pharmaceutical Analyzers variants?

Match the analyzer to the test in the pharmacopoeial monograph or validated method. For raw material identification at goods-in, choose near-infrared or Raman according to packaging, sample form and whether water or glass interferes. For content determination, a potentiometric titrator suits acids, bases and salts; an automatic polarimeter suits chiral substances. For particle size, laser diffraction covers suspensions, powders and aerosols, and the dispersion method must suit the product. Compare wavelength or measurement range, resolution, accuracy, throughput, sample handling and software features such as method storage and audit trail. Confirm that calibration standards, reference libraries and qualification documents are available.

Full specifications

Full specifications
Measuring range±90°
Resolution0.001°
Accuracyabout ±0.01°
Wavelength589 nm standard, others optional
Temperature control15–40 °C, ±0.2 °C
Cell path length100 mm or 200 mm
Light sourceSodium lamp or LED
Power supply220 V, 50 Hz, about 0.1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Chiral drug identity and assay
  • Sugar content determination
  • Racemisation monitoring
  • Raw material quality control

Key features

  • Photoelectric detection of optical rotation
  • Servomotor or Faraday null-point system
  • Temperature-controlled sample cell
  • Specific rotation at 589 nm and 20 °C
  • Digital readout with storage of results
  • Suited to chiral drugs and sugars

Frequently asked questions about Automatic Polarimeter for Pharmaceutical Analysis

Optical rotation changes with temperature, so a drift of a few degrees alters the reading. Instruments with a controlled cell, usually held near 20 °C within 0.2 °C, give results that can be compared against pharmacopoeial values measured at the stated temperature.

Request a quotation for the Automatic Polarimeter for Pharmaceutical Analysis

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.