Near-Infrared Pharmaceutical Analyzer
药品近红外分析仪
- SKU PHA-0001
- Pharmaceutical Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 780–2500 nm |
|---|---|
| Wavelength accuracy | about ±1 nm |
| Photometric noise | about 0.05 mAU or better |
| Scan time | about 5–30 s |
| Sample interface | Reflectance probe or rotating cup |
| Library capacity | hundreds of material models |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <856>, USP <858>, USP <541>
What is the Near-Infrared Pharmaceutical Analyzer?
A near-infrared pharmaceutical analyzer identifies incoming raw materials by measuring their absorption spectrum, often through a plastic bag or container. It is chosen for rapid goods-in identification in pharmaceutical warehouses and quality control laboratories.
What is the Near-Infrared Pharmaceutical Analyzer?
A near-infrared pharmaceutical analyzer identifies incoming raw materials by measuring their absorption spectrum, often through a plastic bag or container. It is chosen for rapid goods-in identification in pharmaceutical warehouses and quality control laboratories.
Overview
The near-infrared analyzer measures the absorption of light between about 780 and 2500 nm, where overtone and combination vibrations of O-H, C-H and N-H bonds create a broad, information-rich spectrum. Because the spectrum arises from molecular structure, it acts as a fingerprint that can identify a material even through a sealed plastic bag, which is the key advantage at goods-in. Chemometric models, built from spectra of reference standards, classify or quantify the sample, and libraries cover hundreds of materials. Instruments range from handheld units with a single measurement window to benchtop systems with rotating sample presentation for powders. Water interferes strongly, so moisture content and humidity must be controlled when building models. Wavelength accuracy, photometric noise and model maintenance determine reliability.
How does it work?
Pharmaceutical analyzers apply spectroscopic, electrochemical or physical measurement principles to drug samples. Near-infrared instruments measure the absorption of light from about 780 to 2500 nm by overtone and combination vibrations of molecular bonds, which gives a fingerprint suitable for identification through packaging. Raman analyzers measure inelastic light scattering and are sensitive to molecular symmetry and crystal form. Potentiometric titrators add reagent until a sensor detects the equivalence point, so the consumed volume gives content. Laser diffraction measures the angular scatter of laser light as particles pass, which is converted to a size distribution. Polarimeters measure optical rotation, a specific property of chiral drug substances. Calibration or verification with reference standards is needed for each technique.
What are the key features?
- Absorption measurement over about 780–2500 nm
- Identification through sealed plastic packaging
- Chemometric models and material libraries
- Handheld or benchtop with powder rotation
- Non-destructive, rapid measurement
- Methods stored for routine goods-in testing
What are the technical specifications?
A typical near-infrared pharmaceutical analyzer configuration offers wavelength range of 780–2500 nm, wavelength accuracy of about ±1 nm, photometric noise of about 0.05 mAU or better, scan time of about 5–30 s, sample interface of Reflectance probe or rotating cup and library capacity of hundreds of material models. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Near-Infrared Pharmaceutical Analyzer is used in raw material identification at goods-in, container-level identity checks, excipient screening and blend uniformity monitoring. Across the wider Pharmaceutical Analyzers class, laboratories also deploy it for raw material identification at goods-in, drug substance assay and excipient quality control.
Which standards and certifications apply?
Relevant standards and methods include USP <856>, USP <858>, USP <541>, USP <429>, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 manufacturing and IEC 61010-1 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install analyzers on a stable bench away from vibration, direct sun and strong draughts, and let them warm up before use. Verify performance with reference standards on a defined schedule, not only when a supplier service visit occurs, and record the results. Keep sample surfaces clean and use fresh consumables such as electrode filling solution and membranes. For near-infrared and Raman, maintain the reference library and re-qualify after any lamp or laser change. Operate under a validated procedure with trained staff, and retain raw spectra or titration curves because regulators may ask for them. Dispose of waste reagents according to local regulations.
How do I select the right Near-Infrared Pharmaceutical Analyzer?
Choose a near-infrared analyzer for rapid, non-destructive identification of incoming materials, especially where packaging must stay sealed. Confirm wavelength range and accuracy, measurement time, probe or cup design for your sample forms, and the availability of validated libraries for your materials. Plan how models will be maintained and re-qualified.
How does it compare with other Pharmaceutical Analyzers variants?
Match the analyzer to the test in the pharmacopoeial monograph or validated method. For raw material identification at goods-in, choose near-infrared or Raman according to packaging, sample form and whether water or glass interferes. For content determination, a potentiometric titrator suits acids, bases and salts; an automatic polarimeter suits chiral substances. For particle size, laser diffraction covers suspensions, powders and aerosols, and the dispersion method must suit the product. Compare wavelength or measurement range, resolution, accuracy, throughput, sample handling and software features such as method storage and audit trail. Confirm that calibration standards, reference libraries and qualification documents are available.
Full specifications
| Wavelength range | 780–2500 nm |
|---|---|
| Wavelength accuracy | about ±1 nm |
| Photometric noise | about 0.05 mAU or better |
| Scan time | about 5–30 s |
| Sample interface | Reflectance probe or rotating cup |
| Library capacity | hundreds of material models |
| Software | Method storage and audit trail options |
| Power supply | 220 V, 50 Hz or battery |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Raw material identification at goods-in
- Container-level identity checks
- Excipient screening
- Blend uniformity monitoring
Key features
- Absorption measurement over about 780–2500 nm
- Identification through sealed plastic packaging
- Chemometric models and material libraries
- Handheld or benchtop with powder rotation
- Non-destructive, rapid measurement
- Methods stored for routine goods-in testing
Frequently asked questions about Near-Infrared Pharmaceutical Analyzer
Yes, this is a main advantage. Near-infrared light penetrates clear or pigmented plastic, so the sealed container can be measured directly, reducing sampling, operator exposure and the risk of contamination during goods-in testing.
Spectra are collected from many batches and suppliers of the material, plus similar materials that could be confused with it, then processed with chemometric software to create a classification model. The model must be validated and maintained as suppliers change.
Yes, water has strong near-infrared absorption, so humidity and sample moisture change the spectrum. Models should account for normal moisture variation, and measurement conditions should be controlled or the sample measured after equilibration.
Common instruments include near-infrared and Raman analyzers for identification, potentiometric titrators for assay, laser diffraction particle size analyzers, polarimeters and spectrophotometers. The selection follows the tests defined in the pharmacopoeial monograph or validated in-house method.
Near-infrared suits bulk identification through plastic bags and is strong for water and hydroxyl-containing materials. Raman is better through glass and for non-polar compounds, and is more sensitive to crystal form. The choice depends on packaging, sample and interference.
Performance should be verified with reference standards at defined intervals, commonly daily or before each use for identity instruments, and after any service, lamp or laser change. Records of verification are part of routine GMP documentation.