Field-Portable Nucleic Acid Extractor

便携式现场核酸提取仪

  • SKU NAE-0005
  • Nucleic Acid Extractors
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Samples per run1–16
Sample volume100–500 µL
Elution volume30–100 µL
Protocol timeapprox. 15–30 min
Lysis temperatureambient to 90 °C
PowerRechargeable battery or 12 V DC, approx. 30 W
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 22174, ISO 15189

What is the Field-Portable Nucleic Acid Extractor?

A field-portable extractor purifies DNA or RNA at the point of sampling using battery-powered magnetic bead cartridges, so that samples need not be transported cold. It supports outbreak response, veterinary testing and environmental surveillance in remote locations.

What is the Field-Portable Nucleic Acid Extractor?

A field-portable extractor purifies DNA or RNA at the point of sampling using battery-powered magnetic bead cartridges, so that samples need not be transported cold. It supports outbreak response, veterinary testing and environmental surveillance in remote locations.

Overview

The portable extractor combines a small magnetic bead module, a heated lysis block and rechargeable batteries in a case that can be carried to a farm, border post or field station. Samples are loaded into sealed cartridges holding lysis buffer, beads, wash solution and elution buffer, and the instrument moves a magnet through the cartridge to complete purification in 15–30 minutes without laboratory pipetting. Eluate can be transferred directly to a portable PCR or isothermal amplification instrument, giving a sample-to-answer workflow in the field. Capacity is typically 1–16 samples per run. Because environmental temperature and power supply vary, protocols should be validated at the extremes expected, and results confirmed by a reference laboratory when a diagnostic decision depends on them.

How does it work?

Extraction starts with lysis, which releases nucleic acid using chaotropic salts such as guanidinium thiocyanate together with detergents, proteinase K or mechanical bead beating for tough samples. In magnetic particle methods, silica-coated or carboxyl-coated beads bind nucleic acid in the presence of high salt and alcohol; a magnetic rod or plate collects the beads while wash buffers remove proteins, salts and PCR inhibitors, and a low-salt elution buffer releases the purified nucleic acid. Silica membrane and glass fibre columns work on the same chemistry but rely on vacuum or centrifugal flow through a membrane. Automated platforms move plates, tips and magnetic rods between heating, mixing, washing and elution positions. Where an internal control and DNase treatment are used, the eluate may be ready for quantitative PCR without further cleanup.

What are the key features?

  • Battery-powered operation with sealed single-use cartridges
  • Integrated lysis heater and magnetic bead module in one case
  • Sample-to-answer compatible with portable PCR instruments
  • Protocol time of 15–30 minutes without laboratory pipetting
  • Rechargeable battery supports several runs between charges
  • Rugged case with cold-chain-free sample handling

What are the technical specifications?

A typical field-portable nucleic acid extractor configuration offers samples per run of 1–16, sample volume of 100–500 µL, elution volume of 30–100 µL, protocol time of approx. 15–30 min, lysis temperature of ambient to 90 °C and power of Rechargeable battery or 12 V DC, approx. 30 W. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Field-Portable Nucleic Acid Extractor is used in point-of-need veterinary and plant testing, outbreak response in remote areas, environmental and water surveillance and border and biosecurity screening. Across the wider Nucleic Acid Extractors class, laboratories also deploy it for molecular diagnostics sample preparation, pathogen detection in food and water and plant and seed genotyping.

Which standards and certifications apply?

Relevant standards and methods include ISO 20395, ISO 22174, ISO 15189, IEC 61010-1, CLSI MM03 and GB/T 19495.3. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the extractor away from post-amplification areas to avoid amplicon contamination, and keep pre-PCR and post-PCR rooms physically separate. Perform daily contamination checks with no-template controls, clean the deck and magnetic rods with 70% ethanol or a validated decontaminant, and replace worn O-rings or rods. Verify yield and purity at installation and after service using a reference sample, and monitor the ratio of absorbance or fluorescence values over time as a trend indicator. Eluates are usually stored at 2–8 °C for short periods or below −20 °C for longer storage; repeated freeze-thaw cycles reduce integrity. For clinical use, extraction performance should be part of the assay validation under ISO 15189, including limit of detection and precision studies.

How do I select the right Field-Portable Nucleic Acid Extractor?

Select a portable extractor when samples cannot be transported or results are needed on site within an hour. Specify cartridge availability per sample type, elution volume, power options, cold storage needs, operating temperature range and compatibility with the portable amplification platform you will use.

How does it compare with other Nucleic Acid Extractors variants?

Selection begins with sample type and volume, since blood, tissue, swabs, stool and plant material differ greatly in lysis difficulty and inhibitor content. Determine the required throughput in samples per run and per day, then choose between magnetic bead platforms for flexibility, 96-well plates for parallel processing, and vacuum manifolds for low-cost manual workflows where a centrifuge is already available. Check whether the chemistry is supplied as open kits or proprietary cartridges, because this controls cost and method development freedom. Elution volume should match downstream needs: quantitative PCR tolerates 50–100 µL eluate, while low-input library preparation often requires a concentration step. Confirm cross-contamination control, barcode tracking, UV decontamination, audit trails and the availability of validated protocols for your matrices.

Full specifications

Full specifications
Samples per run1–16
Sample volume100–500 µL
Elution volume30–100 µL
Protocol timeapprox. 15–30 min
Lysis temperatureambient to 90 °C
PowerRechargeable battery or 12 V DC, approx. 30 W
Operating temperatureapprox. 5–40 °C
Cartridge formatSealed single-use cartridge with prefilled reagents
Weightapprox. 3–6 kg with case
Dimensions (W x D x H)approx. 300 x 250 x 200 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Point-of-need veterinary and plant testing
  • Outbreak response in remote areas
  • Environmental and water surveillance
  • Border and biosecurity screening

Key features

  • Battery-powered operation with sealed single-use cartridges
  • Integrated lysis heater and magnetic bead module in one case
  • Sample-to-answer compatible with portable PCR instruments
  • Protocol time of 15–30 minutes without laboratory pipetting
  • Rechargeable battery supports several runs between charges
  • Rugged case with cold-chain-free sample handling

Frequently asked questions about Field-Portable Nucleic Acid Extractor

Prefilled cartridges are usually stored at 2–30 °C for a defined period, so field use needs only protection from heat and direct sun rather than refrigeration. Check the stated storage range and shelf life, because some proteinase K components are less stable.