Automated Liquid Handling Extraction Workstation
自动化液体处理提取工作站
- SKU NAE-0003
- Nucleic Acid Extractors
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pipetting channels | 8, 96 or 384 (configuration dependent) |
|---|---|
| Volume range | 1–1,000 µL |
| Volumetric accuracy | within ±2% at 200 µL (typical) |
| Deck positions | up to 20 plate and reagent positions |
| Samples per run | 1–96 (or 384 with dedicated heads) |
| Heating module range | ambient to 95 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 22174, ISO 15189
What is the Automated Liquid Handling Extraction Workstation?
An automated liquid handling workstation performs lysis, binding, wash and elution by programmable pipetting on a robotic deck, integrating extraction with normalisation, pooling and library preparation steps. It suits laboratories that need walk-away workflow automation rather than a fixed extraction protocol.
What is the Automated Liquid Handling Extraction Workstation?
An automated liquid handling workstation performs lysis, binding, wash and elution by programmable pipetting on a robotic deck, integrating extraction with normalisation, pooling and library preparation steps. It suits laboratories that need walk-away workflow automation rather than a fixed extraction protocol.
Overview
The workstation uses an air-displacement or positive-displacement pipetting head on a deck that holds sample tubes, reagent troughs, magnetic modules, heating blocks, tip racks and a plate hotel. Users write or import protocols in vendor software, and the instrument executes reagent addition, mixing, magnetic separation, supernatant removal and elution without manual intervention. Because liquid classes and volumes are programmable, the same platform can run nucleic acid extraction, PCR set-up, normalisation and pooling, which reduces operator error and frees staff for other tasks. Deck capacity ranges from a single 96-well plate to more than 20 positions, and multi-channel heads process 8, 96 or 384 wells at once. Validation requires volumetric accuracy checks, channel-to-channel precision studies and a documented change-control process for method edits.
How does it work?
Extraction starts with lysis, which releases nucleic acid using chaotropic salts such as guanidinium thiocyanate together with detergents, proteinase K or mechanical bead beating for tough samples. In magnetic particle methods, silica-coated or carboxyl-coated beads bind nucleic acid in the presence of high salt and alcohol; a magnetic rod or plate collects the beads while wash buffers remove proteins, salts and PCR inhibitors, and a low-salt elution buffer releases the purified nucleic acid. Silica membrane and glass fibre columns work on the same chemistry but rely on vacuum or centrifugal flow through a membrane. Automated platforms move plates, tips and magnetic rods between heating, mixing, washing and elution positions. Where an internal control and DNase treatment are used, the eluate may be ready for quantitative PCR without further cleanup.
What are the key features?
- Programmable pipetting head with 8, 96 or 384 channels
- Interchangeable magnetic, heating and shaking deck modules
- Protocol editor stores validated extraction and PCR set-up methods
- On-deck tip and plate inventory tracking with barcode reading
- Liquid level and clog detection reduce pipetting failures
- Integration with laboratory information systems for sample transfer
What are the technical specifications?
A typical automated liquid handling extraction workstation configuration offers pipetting channels of 8, 96 or 384 (configuration dependent), volume range of 1–1,000 µL, volumetric accuracy of within ±2% at 200 µL (typical), deck positions of up to 20 plate and reagent positions, samples per run of 1–96 (or 384 with dedicated heads) and heating module range of ambient to 95 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Liquid Handling Extraction Workstation is used in sample-to-result molecular diagnostics workflows, combined extraction and PCR plate set-up, next-generation sequencing library normalisation and biobank sample aliquoting and pooling. Across the wider Nucleic Acid Extractors class, laboratories also deploy it for molecular diagnostics sample preparation, pathogen detection in food and water and plant and seed genotyping.
Which standards and certifications apply?
Relevant standards and methods include ISO 20395, ISO 22174, ISO 15189, IEC 61010-1, CLSI MM03 and GB/T 19495.3. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the extractor away from post-amplification areas to avoid amplicon contamination, and keep pre-PCR and post-PCR rooms physically separate. Perform daily contamination checks with no-template controls, clean the deck and magnetic rods with 70% ethanol or a validated decontaminant, and replace worn O-rings or rods. Verify yield and purity at installation and after service using a reference sample, and monitor the ratio of absorbance or fluorescence values over time as a trend indicator. Eluates are usually stored at 2–8 °C for short periods or below −20 °C for longer storage; repeated freeze-thaw cycles reduce integrity. For clinical use, extraction performance should be part of the assay validation under ISO 15189, including limit of detection and precision studies.
How do I select the right Automated Liquid Handling Extraction Workstation?
Select a liquid handling workstation when extraction is one step in an automated workflow and when normalisation, pooling or PCR set-up should run unattended. Specify channel count, volume range and accuracy, deck positions, magnetic and heating modules, software validation features and LIMS integration.
How does it compare with other Nucleic Acid Extractors variants?
Selection begins with sample type and volume, since blood, tissue, swabs, stool and plant material differ greatly in lysis difficulty and inhibitor content. Determine the required throughput in samples per run and per day, then choose between magnetic bead platforms for flexibility, 96-well plates for parallel processing, and vacuum manifolds for low-cost manual workflows where a centrifuge is already available. Check whether the chemistry is supplied as open kits or proprietary cartridges, because this controls cost and method development freedom. Elution volume should match downstream needs: quantitative PCR tolerates 50–100 µL eluate, while low-input library preparation often requires a concentration step. Confirm cross-contamination control, barcode tracking, UV decontamination, audit trails and the availability of validated protocols for your matrices.
Full specifications
| Pipetting channels | 8, 96 or 384 (configuration dependent) |
|---|---|
| Volume range | 1–1,000 µL |
| Volumetric accuracy | within ±2% at 200 µL (typical) |
| Deck positions | up to 20 plate and reagent positions |
| Samples per run | 1–96 (or 384 with dedicated heads) |
| Heating module range | ambient to 95 °C |
| Magnetic module | 96-well magnetic separation plate |
| Software | Protocol editor with audit trail and user levels |
| Data interface | Ethernet, LIMS-ready API |
| Dimensions (W x D x H) | approx. 1,300 x 800 x 900 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Sample-to-result molecular diagnostics workflows
- Combined extraction and PCR plate set-up
- Next-generation sequencing library normalisation
- Biobank sample aliquoting and pooling
Key features
- Programmable pipetting head with 8, 96 or 384 channels
- Interchangeable magnetic, heating and shaking deck modules
- Protocol editor stores validated extraction and PCR set-up methods
- On-deck tip and plate inventory tracking with barcode reading
- Liquid level and clog detection reduce pipetting failures
- Integration with laboratory information systems for sample transfer
Frequently asked questions about Automated Liquid Handling Extraction Workstation
Validation covers volumetric accuracy and precision per channel, carry-over and no-template contamination, positional accuracy, and reproducibility of the full protocol on low and high controls. Documents list acceptance criteria, results and any corrective action before release.
Some models support two independent protocols on one deck, for example DNA from one sample rack and RNA from another. Parallel runs need clearly separated reagent and consumable zones, dedicated tips and a check that no channel crosses into the other workflow and carries contamination.
The platform uses brand-specific or validated tips, plates, reagent reservoirs and magnetic plates. Consumable geometry affects height sensing and accuracy, so most suppliers require their own or a tested alternative, which should be included when comparing running costs.
Magnetic bead methods bind nucleic acid to particles that are collected with a magnet, which suits automation and high throughput. Column methods bind nucleic acid on a silica membrane and rely on vacuum or centrifugation. Both give comparable purity when the protocol is followed.
Inhibition usually comes from residual ethanol, guanidinium salts, haemoglobin, humic acids or polysaccharides carried over from the sample matrix. Additional wash steps, a longer drying step before elution, or dilution of the eluate generally resolves it. Internal controls help confirm inhibition.
Bench magnetic bead instruments typically accept 200–1,000 µL per sample, while 96-well platforms usually work with 200–500 µL. Larger volume protocols improve sensitivity for low-titre samples but need longer lysis and binding times.