MALDI-TOF Microbial Identification System
MALDI-TOF 微生物鉴定系统
- SKU MTE-0003
- Microbiology Testing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Mass range | 2,000–20,000 Da |
|---|---|
| Laser | Nitrogen, 337 nm |
| Target format | 96-spot polished steel |
| Identification time | Seconds per spot after preparation |
| Sample preparation | Direct transfer or formic acid extraction |
| Mass accuracy | ≤ 500 ppm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7218, ISO 6579, ISO 11290
What is the MALDI-TOF Microbial Identification System?
A MALDI-TOF system identifies bacterial, yeast and mould isolates from their protein mass fingerprints within minutes. It replaces biochemical identification in busy food, environmental and hygiene laboratories that culture many colonies per week.
What is the MALDI-TOF Microbial Identification System?
A MALDI-TOF system identifies bacterial, yeast and mould isolates from their protein mass fingerprints within minutes. It replaces biochemical identification in busy food, environmental and hygiene laboratories that culture many colonies per week.
Overview
A single colony is mixed with a matrix solution, dried on a target plate and ionised by a laser. The time-of-flight analyser measures the mass-to-charge ratio of the resulting protein ions, giving a spectrum that is characteristic of the species. Software compares this spectrum with a reference database and returns the best matches with a score; scores above the validated threshold indicate reliable species-level identification. Sample preparation is simple, analysis takes seconds per spot, and a 96-spot target allows a full batch in about 30 minutes. The database must cover the organisms relevant to food and environmental testing, and unusual or new species may still require sequencing. Confirmation of identification is advisable for regulatory decisions.
How does it work?
Culture-based methods remain the reference: a measured portion of sample is homogenised, enriched and plated on selective media, incubated at a set temperature, and colonies are counted and reported as colony-forming units per gram or millilitre. Rapid methods shorten the result time by detecting specific molecules. Real-time PCR amplifies pathogen DNA and reads fluorescence cycle by cycle. Immunoassays detect antigens or toxins with antibodies in microplate or lateral-flow formats. MALDI-TOF mass spectrometry identifies isolates from their protein fingerprints within minutes. ATP luminometry measures adenosine triphosphate as a general indicator of organic residue and microbial load on surfaces. Each rapid method must be validated against the cultural reference for the matrix in use.
What are the key features?
- Time-of-flight mass analyser with 337 nm laser
- 96-spot target plate for batch analysis
- Database covering bacteria, yeasts and moulds
- Identification in seconds per spot with confidence scores
- Simple direct-transfer sample preparation
- Optional automated target preparation for high throughput
What are the technical specifications?
A typical maldi-tof microbial identification system configuration offers mass range of 2,000–20,000 Da, laser of Nitrogen, 337 nm, target format of 96-spot polished steel, identification time of Seconds per spot after preparation, sample preparation of Direct transfer or formic acid extraction and mass accuracy of ≤ 500 ppm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The MALDI-TOF Microbial Identification System is used in rapid identification of food isolates, environmental and hygiene monitoring isolates, spoilage organism identification in beverages and confirmatory identification after selective plating. Across the wider Microbiology Testing class, laboratories also deploy it for pathogen testing of ready-to-eat and raw foods, hygiene and environmental monitoring in food plants and shelf-life and challenge testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 7218, ISO 6579, ISO 11290, ISO 16649, ISO 4833, ISO 21528 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Microbiology laboratories need separate clean and contaminated zones, controlled air flow, autoclave capacity and safe waste handling. Culture media and antibiotics have shelf life and must be stored correctly, and incubators require temperature mapping and monitoring. Rapid kits need positive and negative controls in every run, and results near the limit of detection should be confirmed by culture. Environmental monitoring programmes define sampling points, frequency and action levels. Keep validation records against ISO 7218 and the relevant organism standards, and confirm that suppliers provide training, proficiency-testing support and timely consumables.
How do I select the right MALDI-TOF Microbial Identification System?
Choose MALDI-TOF when you identify many isolates and want to cut days of biochemical testing to minutes. Verify that the reference database covers the species you encounter, including spoilage and environmental organisms. Confirm service coverage, database update policy and whether automated target preparation is needed for your workload.
How does it compare with other Microbiology Testing variants?
Begin with the organisms and limits your regulation or customer specification names, then decide between cultural and rapid methods. Cultural methods are the accredited reference and cost less per test but take days, so they suit scheduled production and confirmatory work. PCR and immunoassay platforms give results within hours, which helps hold time-sensitive or short-shelf-life products, but they need validation, controls and staff training. MALDI-TOF identification reduces the time to identify isolates from days to minutes. Add ATP luminometry and air sampling for environmental and hygiene monitoring. Compare consumable cost per test, walkaway automation and local technical support.
Full specifications
| Mass range | 2,000–20,000 Da |
|---|---|
| Laser | Nitrogen, 337 nm |
| Target format | 96-spot polished steel |
| Identification time | Seconds per spot after preparation |
| Sample preparation | Direct transfer or formic acid extraction |
| Mass accuracy | ≤ 500 ppm |
| Database size | Several thousand species |
| Batch capacity | 96 spots in about 30 min |
| Software | Identification scoring and audit trail |
| Footprint | Benchtop, under 1 m width |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Rapid identification of food isolates
- Environmental and hygiene monitoring isolates
- Spoilage organism identification in beverages
- Confirmatory identification after selective plating
Key features
- Time-of-flight mass analyser with 337 nm laser
- 96-spot target plate for batch analysis
- Database covering bacteria, yeasts and moulds
- Identification in seconds per spot with confidence scores
- Simple direct-transfer sample preparation
- Optional automated target preparation for high throughput
Frequently asked questions about MALDI-TOF Microbial Identification System
With an adequate database and good spectra, most isolates are identified to species level with high confidence, and scores are reported with thresholds that indicate reliability. Closely related species and mixes may reach only genus level, and those isolates should be confirmed.
A fresh colony is smeared on the target spot, covered with matrix solution and allowed to dry. If direct transfer gives a poor spectrum, a formic acid or ethanol extraction is used to free more protein before analysis.
Yes, provided the database includes them and the extraction protocol is adapted, since fungal cell walls need stronger lysis. Yeast identification is well established, while mould identification is less standardised and often needs confirmatory sequencing.
Culture methods are the validated reference against which rapid methods are compared, they detect viable organisms and they remain accepted for regulatory decisions. Their main drawback is the several days needed for enrichment, plating, incubation and confirmation.
PCR methods typically give a result within 12 to 24 hours including enrichment, and immunoassays in 20 minutes to several hours. They shorten holding time but still require pre-enrichment for most pathogens because the infectious dose is low.
An ATP swab measures adenosine triphosphate on a surface, which indicates organic residue or microbial contamination after cleaning. It is a rapid pass/fail indicator used to verify cleaning, but it does not identify organisms or replace microbiological monitoring.