

LC-MS/MS System for Veterinary Drug Residue Analysis
兽药残留分析 LC-MS/MS 系统
- SKU COA-0004
- Contaminant Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IQ/OQ documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Mass analyser | Triple quadrupole |
|---|---|
| Mass range | 5–2000 m/z |
| Analytes per run | 100–200 veterinary drugs |
| Detection limits | 0.1–5 µg/kg |
| Run time | 12–20 min per injection |
| Ionisation | Electrospray with polarity switching |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 17294-2, EPA 6020B, Commission Regulation (EU) 2023/915
What is the LC-MS/MS System for Veterinary Drug Residue Analysis?
An LC-MS/MS system for veterinary drug residues quantifies antibiotics, hormones, anthelmintics and coccidiostats at microgram per kilogram levels in meat, milk, eggs, honey and aquaculture products. It supports maximum residue limit compliance and export certification.
What is the LC-MS/MS System for Veterinary Drug Residue Analysis?
An LC-MS/MS system for veterinary drug residues quantifies antibiotics, hormones, anthelmintics and coccidiostats at microgram per kilogram levels in meat, milk, eggs, honey and aquaculture products. It supports maximum residue limit compliance and export certification.
Overview
Samples are extracted with buffered acetonitrile or methanol and cleaned with solid-phase extraction to remove fat and protein. After separation on a reversed-phase column, compounds are ionised by electrospray and monitored in selected reaction monitoring mode, usually with two transitions per analyte for confirmation. Broad multi-class methods can cover 100 to 200 analytes in one run of 12 to 20 minutes, which suits monitoring programmes that check several drug families together. Isotope-labelled analogues or matrix-matched calibration correct for recovery and ion suppression. Detection limits of 0.1–5 µg/kg support the low maximum residue limits set for many antibiotics and growth promoters in animal products.
How does it work?
Contaminant analysis combines an extraction and clean-up step with an element-selective or mass-selective detector. Elemental contaminants are measured by atomic spectroscopy: samples are digested in strong acid under heat or microwave energy, then aspirated into flame atomic absorption, graphite furnace atomic absorption or an inductively coupled plasma coupled to mass spectrometry, which reaches microgram per kilogram levels for lead, cadmium, arsenic and mercury. Organic contaminants are measured by chromatography with mass detection. Mycotoxins and veterinary drug residues are separated by liquid chromatography and detected by tandem mass spectrometry in selected reaction monitoring mode. Process contaminants such as acrylamide, chloropropanols and polycyclic aromatic hydrocarbons are usually separated by gas chromatography with tandem mass detection. Isotope-labelled internal standards correct recovery and matrix effects.
What are the key features?
- Multi-class methods covering 100–200 veterinary drugs per run
- Two or more transitions per analyte for confirmation
- Detection limits 0.1–5 µg/kg in animal matrices
- Compatibility with solid-phase extraction clean-up
- Polarity switching in a single injection
- MRL library and audit-trail reporting software
What are the technical specifications?
A typical lc-ms/ms system for veterinary drug residue analysis configuration offers mass analyser of Triple quadrupole, mass range of 5–2000 m/z, analytes per run of 100–200 veterinary drugs, detection limits of 0.1–5 µg/kg, run time of 12–20 min per injection and ionisation of Electrospray with polarity switching. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The LC-MS/MS System for Veterinary Drug Residue Analysis is used in antibiotic residue monitoring in meat and milk, aquaculture drug residue testing, honey and egg residue control and export certification and import compliance. Across the wider Contaminant Analysis class, laboratories also deploy it for heavy metal monitoring in rice, seafood and infant food, mycotoxin testing of cereals, nuts and spices and veterinary drug residue control in meat and aquaculture.
Which standards and certifications apply?
Relevant standards and methods include ISO 17294-2, EPA 6020B, Commission Regulation (EU) 2023/915, EN 15662, ISO 16050, SANTE/11312/2021 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IQ/OQ documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Trace analysis is easily compromised by contamination from reagents, glassware and laboratory air. Use high-purity acids, digested blank checks and a clean, dedicated preparation area, and verify instrument performance with certified reference materials and recovery spiking. Collision or reaction cell gases and tuning solutions must meet the instrument specification, and elemental calibrations need regular verification because drift affects low-level results. For organic contaminants, reference standards are expensive and unstable, so storage and preparation records matter. Laboratories should participate in proficiency testing for the contaminants they report and keep confirmatory ion-ratio criteria under review.
How do I select the right LC-MS/MS System for Veterinary Drug Residue Analysis?
Select LC-MS/MS when your monitoring plan covers many drug classes and requires microgram per kilogram confirmation. Confirm the analyte coverage of the method packages, the polarity-switching performance and the availability of isotope-labelled standards for key analytes. Consider whether an automated clean-up step is justified by sample numbers.
How does it compare with other Contaminant Analysis variants?
Choose the elemental technique from the number of elements and the sensitivity required. ICP-MS covers many elements in one run at microgram per kilogram levels and is the default for lead, cadmium, arsenic and mercury, with a speciation option for inorganic arsenic and methylmercury. Flame atomic absorption is economical for higher concentrations of a single element such as sodium, calcium or zinc, while graphite furnace atomic absorption serves low levels where ICP-MS is not available. For organic contaminants, select LC-MS/MS for mycotoxins and veterinary drugs and GC-MS/MS for process contaminants and packaging migrants. Confirm that the compound library, reference standards and validated clean-up procedures exist for your matrices, and compare detection limits with the regulatory maximum levels.
Full specifications
| Mass analyser | Triple quadrupole |
|---|---|
| Mass range | 5–2000 m/z |
| Analytes per run | 100–200 veterinary drugs |
| Detection limits | 0.1–5 µg/kg |
| Run time | 12–20 min per injection |
| Ionisation | Electrospray with polarity switching |
| Transitions per analyte | 2–3 |
| Sample preparation | Buffered extraction and SPE clean-up |
| Matrix scope | Meat, milk, eggs, honey, fish |
| Software | MRL checking, audit trail, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Antibiotic residue monitoring in meat and milk
- Aquaculture drug residue testing
- Honey and egg residue control
- Export certification and import compliance
Key features
- Multi-class methods covering 100–200 veterinary drugs per run
- Two or more transitions per analyte for confirmation
- Detection limits 0.1–5 µg/kg in animal matrices
- Compatibility with solid-phase extraction clean-up
- Polarity switching in a single injection
- MRL library and audit-trail reporting software
Frequently asked questions about LC-MS/MS System for Veterinary Drug Residue Analysis
Common targets are tetracyclines, sulfonamides, quinolones, penicillins, macrolides, aminoglycosides, chloramphenicol, nitrofurans, anthelmintics, coccidiostats and hormone or beta-agonist growth promoters. The exact panel reflects national residue control plans.
Two or more fragment transitions with correct ion ratios provide confirmatory evidence that the detected signal comes from the target compound and not a similar background ion, as required by residue analysis guidance for regulatory reporting.
Tissues and dairy products are homogenised and extracted with buffered organic solvent, then cleaned by solid-phase extraction or dispersive sorbents. Enzymatic digestion is sometimes used to release bound residues such as nitrofuran metabolites.
Typical regulated contaminants are lead, cadmium, mercury, arsenic, tin, mycotoxins such as aflatoxins and ochratoxin A, process contaminants such as acrylamide, and residues of pesticides and veterinary drugs. Specific maximum levels depend on the commodity and jurisdiction.
ICP-MS measures many elements in a single run at microgram per kilogram levels, has a wide dynamic range and can be coupled with chromatography for speciation. That combination suits the low maximum levels and multielement reporting required for food.
Samples are usually digested in high-purity nitric acid, sometimes with hydrogen peroxide, using a closed microwave system to prevent loss of volatile elements. Digests are diluted and analysed against matrix-matched calibration standards with internal standards.
Related models






