GC-MS/MS System for Process Contaminant Analysis
加工污染物分析 GC-MS/MS 系统
- SKU COA-0005
- Contaminant Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IQ/OQ documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Mass analyser | Triple quadrupole or ion trap |
|---|---|
| Mass range | 10–1050 m/z |
| Ionisation | Electron impact and chemical ionisation |
| Detection limits | 1–10 µg/kg for acrylamide and chloropropanols |
| Column oven range | 40–350 °C |
| Sampling options | Liquid, headspace, SPME |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 17294-2, EPA 6020B, Commission Regulation (EU) 2023/915
What is the GC-MS/MS System for Process Contaminant Analysis?
A GC-MS/MS system measures process contaminants such as acrylamide, chloropropanols, polycyclic aromatic hydrocarbons and packaging migrants at microgram per kilogram levels. It is used where heat treatment or packaging can create residues in food.
What is the GC-MS/MS System for Process Contaminant Analysis?
A GC-MS/MS system measures process contaminants such as acrylamide, chloropropanols, polycyclic aromatic hydrocarbons and packaging migrants at microgram per kilogram levels. It is used where heat treatment or packaging can create residues in food.
Overview
Volatile and semi-volatile contaminants are separated on a capillary column and detected by tandem mass spectrometry in selected reaction monitoring mode, which suppresses matrix background and allows reliable quantification at low levels. Acrylamide is usually extracted in water, treated to improve volatility and analysed with labelled internal standards. Chloropropanols and glycidyl esters require ester cleavage or conversion before analysis. Polycyclic aromatic hydrocarbons are extracted from smoked or grilled products and cleaned by gel permeation or solid-phase chromatography. Headspace and solid-phase microextraction options cover packaging migrants such as residual monomers and plasticisers. The technique complements LC-MS/MS for the more polar contaminants and shares sample-preparation facilities with it.
How does it work?
Contaminant analysis combines an extraction and clean-up step with an element-selective or mass-selective detector. Elemental contaminants are measured by atomic spectroscopy: samples are digested in strong acid under heat or microwave energy, then aspirated into flame atomic absorption, graphite furnace atomic absorption or an inductively coupled plasma coupled to mass spectrometry, which reaches microgram per kilogram levels for lead, cadmium, arsenic and mercury. Organic contaminants are measured by chromatography with mass detection. Mycotoxins and veterinary drug residues are separated by liquid chromatography and detected by tandem mass spectrometry in selected reaction monitoring mode. Process contaminants such as acrylamide, chloropropanols and polycyclic aromatic hydrocarbons are usually separated by gas chromatography with tandem mass detection. Isotope-labelled internal standards correct recovery and matrix effects.
What are the key features?
- Tandem mass detection with selected reaction monitoring
- Acrylamide, chloropropanol and PAH method packages
- Isotope-labelled internal standards for quantification
- Headspace and SPME options for volatile migrants
- Capillary column oven programmable to 350 °C
- Software with method packages and audit trail
What are the technical specifications?
A typical gc-ms/ms system for process contaminant analysis configuration offers mass analyser of Triple quadrupole or ion trap, mass range of 10–1050 m/z, ionisation of Electron impact and chemical ionisation, detection limits of 1–10 µg/kg for acrylamide and chloropropanols, column oven range of 40–350 °C and sampling options of Liquid, headspace, SPME. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The GC-MS/MS System for Process Contaminant Analysis is used in acrylamide testing of fried and baked products, chloropropanol control in refined oils and sauces, PAH monitoring in smoked and grilled foods and packaging migrant and residual monomer testing. Across the wider Contaminant Analysis class, laboratories also deploy it for heavy metal monitoring in rice, seafood and infant food, mycotoxin testing of cereals, nuts and spices and veterinary drug residue control in meat and aquaculture.
Which standards and certifications apply?
Relevant standards and methods include ISO 17294-2, EPA 6020B, Commission Regulation (EU) 2023/915, EN 15662, ISO 16050, SANTE/11312/2021 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IQ/OQ documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Trace analysis is easily compromised by contamination from reagents, glassware and laboratory air. Use high-purity acids, digested blank checks and a clean, dedicated preparation area, and verify instrument performance with certified reference materials and recovery spiking. Collision or reaction cell gases and tuning solutions must meet the instrument specification, and elemental calibrations need regular verification because drift affects low-level results. For organic contaminants, reference standards are expensive and unstable, so storage and preparation records matter. Laboratories should participate in proficiency testing for the contaminants they report and keep confirmatory ion-ratio criteria under review.
How do I select the right GC-MS/MS System for Process Contaminant Analysis?
Choose GC-MS/MS when process contaminants or volatile migrants are in your monitoring plan and you need quantification at low microgram per kilogram levels. Confirm that method packages and labelled internal standards exist for your analytes, and specify headspace or SPME if packaging migrants are relevant. Verify detection limits against the regulatory levels you must meet.
How does it compare with other Contaminant Analysis variants?
Choose the elemental technique from the number of elements and the sensitivity required. ICP-MS covers many elements in one run at microgram per kilogram levels and is the default for lead, cadmium, arsenic and mercury, with a speciation option for inorganic arsenic and methylmercury. Flame atomic absorption is economical for higher concentrations of a single element such as sodium, calcium or zinc, while graphite furnace atomic absorption serves low levels where ICP-MS is not available. For organic contaminants, select LC-MS/MS for mycotoxins and veterinary drugs and GC-MS/MS for process contaminants and packaging migrants. Confirm that the compound library, reference standards and validated clean-up procedures exist for your matrices, and compare detection limits with the regulatory maximum levels.
Full specifications
| Mass analyser | Triple quadrupole or ion trap |
|---|---|
| Mass range | 10–1050 m/z |
| Ionisation | Electron impact and chemical ionisation |
| Detection limits | 1–10 µg/kg for acrylamide and chloropropanols |
| Column oven range | 40–350 °C |
| Sampling options | Liquid, headspace, SPME |
| Run time | 15–30 min per injection |
| Carrier gas | Helium, 1–2 mL/min |
| Internal standards | Deuterated or 13C-labelled analogues |
| Software | Method packages, audit trail, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Acrylamide testing of fried and baked products
- Chloropropanol control in refined oils and sauces
- PAH monitoring in smoked and grilled foods
- Packaging migrant and residual monomer testing
Key features
- Tandem mass detection with selected reaction monitoring
- Acrylamide, chloropropanol and PAH method packages
- Isotope-labelled internal standards for quantification
- Headspace and SPME options for volatile migrants
- Capillary column oven programmable to 350 °C
- Software with method packages and audit trail
Frequently asked questions about GC-MS/MS System for Process Contaminant Analysis
They are substances formed during processing rather than added as ingredients, such as acrylamide from high-temperature frying, chloropropanols from oil refining and polycyclic aromatic hydrocarbons from smoking or grilling. Some are regulated with maximum levels.
Most process contaminants are volatile or semi-volatile and ionise well under electron impact. Tandem mass detection reduces matrix background in complex foods, allowing reliable quantification at microgram per kilogram levels with confirmatory transitions.
Acrylamide is extracted from the homogenised sample with water, cleaned and, in some methods, derivatised or brominated to improve chromatography. Quantification uses deuterated acrylamide as internal standard, with detection limits of a few micrograms per kilogram.
Typical regulated contaminants are lead, cadmium, mercury, arsenic, tin, mycotoxins such as aflatoxins and ochratoxin A, process contaminants such as acrylamide, and residues of pesticides and veterinary drugs. Specific maximum levels depend on the commodity and jurisdiction.
ICP-MS measures many elements in a single run at microgram per kilogram levels, has a wide dynamic range and can be coupled with chromatography for speciation. That combination suits the low maximum levels and multielement reporting required for food.
Samples are usually digested in high-purity nitric acid, sometimes with hydrogen peroxide, using a closed microwave system to prevent loss of volatile elements. Digests are diluted and analysed against matrix-matched calibration standards with internal standards.