CO2 Microplate Incubator for Cell-Based Assays
细胞检测用 CO2 微孔板培养箱
- SKU MII-0003
- Microplate Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient +5 to 50 °C |
|---|---|
| Temperature uniformity | ±0.3 °C |
| CO2 control range | 0–20% |
| CO2 accuracy | ±0.2% |
| Relative humidity | > 90% |
| Chamber volume | 50–400 L |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1
What is the CO2 Microplate Incubator for Cell-Based Assays?
A CO2 microplate incubator holds plates at 37 degrees Celsius, 5 percent carbon dioxide and high humidity, the standard culture environment for mammalian cells. It is used for cell-based assays, cytotoxicity testing and cell culture in multi-well plates.
What is the CO2 Microplate Incubator for Cell-Based Assays?
A CO2 microplate incubator holds plates at 37 degrees Celsius, 5 percent carbon dioxide and high humidity, the standard culture environment for mammalian cells. It is used for cell-based assays, cytotoxicity testing and cell culture in multi-well plates.
Overview
CO2 incubators regulate temperature at 37 degrees with uniformity of plus or minus 0.3 degrees, carbon dioxide at 0 to 20 percent using an infrared or thermal conductivity sensor, and relative humidity above 90 percent using a water pan or humidifier. Air-jacketed or water-jacketed chambers and direct heating ensure stability, and HEPA filtration, copper-alloy surfaces and automatic high-temperature sterilization reduce contamination risk. Capacity ranges from 50 to 400 liters, with shelves for dozens of plates, and some models include a stacker-compatible door or robotic interface. Oxygen control at 1 to 21 percent is available for hypoxia studies. CO2 recovery after door opening takes 5 to 10 minutes and gas consumption matters in large cylinders. Regular cleaning and calibration are required to control contamination and drift.
How does it work?
Microplate incubators maintain a uniform thermal environment around plates. Forced-air designs circulate heated air through the chamber with a fan, heater and a platinum resistance sensor feeding a PID controller, giving uniformity within about plus or minus 0.5 degrees Celsius. Dry-block designs conduct heat from an aluminum block that contacts the plate base, with Peltier elements for heating and cooling. Humidity is generated by a water reservoir or ultrasonic humidifier and monitored by a sensor, preventing evaporation from wells. CO2 incubators add infrared or thermal conductivity sensors and gas solenoid valves to hold 5 percent carbon dioxide for bicarbonate-buffered media. Shaking incubators combine these conditions with orbital motion. Door seals, insulation and heated lids limit gradients and condensation, which otherwise produce edge effects between outer and inner wells.
What are the key features?
- 37 degrees Celsius with uniformity of plus or minus 0.3 degrees
- Infrared or thermal conductivity CO2 sensor for 0 to 20 percent control
- Relative humidity above 90 percent with water pan or humidifier
- HEPA filtration and copper-alloy surfaces reduce contamination risk
- Automatic high-temperature sterilization cycle on many models
- Optional O2 control from 1 to 21 percent for hypoxia studies
What are the technical specifications?
A typical co2 microplate incubator for cell-based assays configuration offers temperature range of Ambient +5 to 50 °C, temperature uniformity of ±0.3 °C, CO2 control range of 0–20%, CO2 accuracy of ±0.2%, relative humidity of > 90% and chamber volume of 50–400 L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The CO2 Microplate Incubator for Cell-Based Assays is used in cytotoxicity and viability plate assays, mammalian cell culture in multi-well plates, reporter gene assay incubation, compound screening incubation and hypoxia and stem cell studies. Across the wider Microplate Incubators class, laboratories also deploy it for ELISA and immunoassay incubation, bacterial growth and susceptibility testing and mammalian cell culture in plates.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, ANSI/SLAS 1-2004 to 4-2004, ISO 13485 (IVD workflows) and EN 12469 (for biosafety-related enclosures, where applicable). Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a level surface away from drafts, direct sunlight and heat sources, with clearance for ventilation. Map temperature with calibrated probes in loaded and empty conditions at installation and periodically, and record set point drift. Use distilled or deionized water in humidity reservoirs and clean them regularly to prevent microbial growth. Clean interior surfaces with disinfectants compatible with the chamber material, and run sterilization cycles where available. Avoid frequent door openings, and allow recovery time for temperature and CO2. Calibrate CO2 sensors against a reference analyzer, and keep alarms active for unattended runs.
How do I select the right CO2 Microplate Incubator for Cell-Based Assays?
Choose this variant when assays need a physiological atmosphere for mammalian cells. It is unnecessary for ELISA and bacterial work, where a simpler incubator costs less. In an RFQ specify chamber volume, CO2 sensor type, O2 control, sterilization method, shelf capacity and automation interface.
How does it compare with other Microplate Incubators variants?
Match the incubator to assay temperature, duration and atmosphere. Dry-block or forced-air models are enough for ELISA and binding steps at 25 to 37 degrees. Use a humidified chamber for long incubations to limit evaporation. Mammalian cell assays need CO2 and humidity control, while bacterial growth may need shaking and temperatures up to 60 degrees. Check capacity in plates, uniformity and recovery time after door opening, plus cooling below ambient for refrigerated incubations. Consider footprint, compatibility with stackers and readers, contamination control features such as HEPA filtration or copper surfaces, data logging and alarms. For regulated laboratories, verify temperature mapping documentation, calibration certificates and audit trail capabilities.
Full specifications
| Temperature range | Ambient +5 to 50 °C |
|---|---|
| Temperature uniformity | ±0.3 °C |
| CO2 control range | 0–20% |
| CO2 accuracy | ±0.2% |
| Relative humidity | > 90% |
| Chamber volume | 50–400 L |
| CO2 recovery (door open 30 s) | ≤ 8 min to 5% |
| Sterilization | High-temperature 140 °C dry heat or H2O2 option |
| Filtration | HEPA, 99.97% at 0.3 µm |
| O2 control (optional) | 1–21% |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cytotoxicity and viability plate assays
- Mammalian cell culture in multi-well plates
- Reporter gene assay incubation
- Compound screening incubation
- Hypoxia and stem cell studies
Key features
- 37 degrees Celsius with uniformity of plus or minus 0.3 degrees
- Infrared or thermal conductivity CO2 sensor for 0 to 20 percent control
- Relative humidity above 90 percent with water pan or humidifier
- HEPA filtration and copper-alloy surfaces reduce contamination risk
- Automatic high-temperature sterilization cycle on many models
- Optional O2 control from 1 to 21 percent for hypoxia studies
Frequently asked questions about CO2 Microplate Incubator for Cell-Based Assays
Carbon dioxide dissolves in medium to form carbonic acid, which with sodium bicarbonate buffers pH near 7.4. Five percent CO2 is the typical level for standard bicarbonate-buffered media.
Infrared sensors are unaffected by humidity and recover faster after door opening, giving more stable control, while thermal conductivity sensors are cheaper but need humidity to be stable and recalibrate more often.
Use HEPA filtration, copper-alloy surfaces, clean water in the humidity pan, regular disinfection and high-temperature sterilization cycles. Limit door openings and keep plates sealed or lidded.
Most ELISA steps are run at 37 degrees Celsius for 30 to 120 minutes, or at room temperature, or overnight at 2 to 8 degrees, depending on the kit. Incubators should hold the set temperature uniformly across all wells.
The edge effect is a difference in results between outer and inner wells caused by faster evaporation and temperature gradients at plate edges. Humidified chambers, sealing films and filling outer wells with liquid reduce it.
Only for mammalian cell assays in bicarbonate-buffered media, which require about 5 percent carbon dioxide to keep pH. ELISA, bacterial growth and HEPES-buffered assays do not need CO2.