Karl Fischer Titrator for Food Moisture
食品卡尔费休水分滴定仪
- SKU MAN-0005
- Moisture Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Titration mode | Volumetric and coulometric |
|---|---|
| Measuring range (volumetric) | 0.1–100 percent water |
| Measuring range (coulometric) | 10 µg–10 mg water |
| Resolution | 0.1 µg water |
| Sample introduction | Direct injection or oven transfer |
| Oven temperature | 50–250 °C, programmable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 712, ISO 6496, AOAC 925.10
What is the Karl Fischer Titrator for Food Moisture?
A Karl Fischer titrator measures water content chemically through the iodine-sulfur dioxide reaction, giving water-specific results for oils, low-moisture powders and products containing volatiles. It is the reference alternative to loss-on-drying methods.
What is the Karl Fischer Titrator for Food Moisture?
A Karl Fischer titrator measures water content chemically through the iodine-sulfur dioxide reaction, giving water-specific results for oils, low-moisture powders and products containing volatiles. It is the reference alternative to loss-on-drying methods.
Overview
In the presence of water, iodine, sulfur dioxide and an alcohol react in a 1:1 stoichiometry with water, and the titrator measures the iodine consumed either volumetrically or coulometrically. Volumetric titration suits water contents from about 0.1 to 100 percent, while coulometric titration reaches microgram levels for very dry samples. Food samples can be injected directly when liquid, or heated in an oven and the released water carried into the titration cell to avoid contact between solids and reagents. Reagents are moisture-sensitive, so the cell is sealed, solvent is replaced regularly, and drift is measured before each run. Results are reported in percent, mg/kg or ppm, and the method is widely specified for edible oils, cocoa, dried fruit and instant powders.
How does it work?
Loss-on-drying instruments weigh a sample, heat it with an infrared or halogen lamp, and track mass until it stabilises; the mass loss is reported as moisture. Halogen lamps reach the drying temperature faster and distribute heat more evenly than infrared. Microwave drying drives water out from within the sample, which suits bulky or dense products. Capacitance meters in grain-moisture devices correlate the dielectric constant of a packed sample with water content using stored calibrations. Karl Fischer titration measures water chemically, by the iodine-sulfur dioxide reaction, and is the reference for low-moisture foods, oils and powders where volatiles would bias loss-on-drying. Vacuum oven drying remains the gravimetric reference method for many commodities.
What are the key features?
- Volumetric or coulometric titration modes
- Water-specific stoichiometric reaction
- Oven accessory for solid and paste samples
- Sealed cell with automatic drift monitoring
- Detection from microgram to percent water levels
- Results in percent, mg/kg or ppm with audit trail
What are the technical specifications?
A typical karl fischer titrator for food moisture configuration offers titration mode of Volumetric and coulometric, measuring range (volumetric) of 0.1–100 percent water, measuring range (coulometric) of 10 µg–10 mg water, resolution of 0.1 µg water, sample introduction of Direct injection or oven transfer and oven temperature of 50–250 °C, programmable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Karl Fischer Titrator for Food Moisture is used in edible oil and fat water content, cocoa, chocolate and confectionery moisture, dried fruit, instant powder and low-moisture foods and spice and seasoning water determination. Across the wider Moisture Analyzers class, laboratories also deploy it for grain intake moisture and safe storage decisions, nutrition labelling and dry-basis calculations and in-process control of drying and blending.
Which standards and certifications apply?
Relevant standards and methods include ISO 712, ISO 6496, AOAC 925.10, ISO 760, ASTM E203 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Moisture results depend on sample handling, so grinding, portion size, spreading and cooling time must follow the method. Loss-on-drying instruments need periodic verification with reference materials or a drying oven comparison, and the balance inside them should be checked with traceable weights. Karl Fischer reagents are moisture-sensitive and need fresh solvent, correct titration parameters and regular drift checks. Capacitance meters must be set to the right crop calibration and corrected for temperature. Keep records of reference-method comparisons and store instruments away from draughts, direct sunlight and heat sources.
How do I select the right Karl Fischer Titrator for Food Moisture?
Select a Karl Fischer titrator when the product contains volatiles, when the method specifies it, or when very low water contents must be quantified. Choose volumetric mode for general work and coulometric mode for trace water, and add an oven if you handle solids and pastes.
How does it compare with other Moisture Analyzers variants?
Match the method to the product and to the accuracy you must report. Loss-on-drying analysers are fast and simple and are ideal for routine control of powders, pastes and liquids, but volatile components other than water can cause a positive bias. Halogen models heat faster and suit high sample numbers, while microwave models handle dense or bulky products better. Capacitance meters are convenient for grain at intake but depend on crop-specific calibrations and are affected by temperature. Karl Fischer titration is required for oils, low-moisture powders and any product where the reference method specifies it. Confirm repeatability, sample size and the ability to store and export results.
Full specifications
| Titration mode | Volumetric and coulometric |
|---|---|
| Measuring range (volumetric) | 0.1–100 percent water |
| Measuring range (coulometric) | 10 µg–10 mg water |
| Resolution | 0.1 µg water |
| Sample introduction | Direct injection or oven transfer |
| Oven temperature | 50–250 °C, programmable |
| Drift monitoring | Automatic before each determination |
| Reagents | Methanol-based or solvent-free |
| Burette volume | 10 mL or 20 mL |
| Data output | USB, LIMS export, audit trail |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Edible oil and fat water content
- Cocoa, chocolate and confectionery moisture
- Dried fruit, instant powder and low-moisture foods
- Spice and seasoning water determination
Key features
- Volumetric or coulometric titration modes
- Water-specific stoichiometric reaction
- Oven accessory for solid and paste samples
- Sealed cell with automatic drift monitoring
- Detection from microgram to percent water levels
- Results in percent, mg/kg or ppm with audit trail
Frequently asked questions about Karl Fischer Titrator for Food Moisture
Karl Fischer measures water specifically through a chemical reaction, so it is unaffected by other volatiles that would inflate a loss-on-drying result. It is also far more sensitive at very low water contents.
Volumetric titration adds iodine from a burette and suits water contents from about 0.1 to 100 percent. Coulometric titration generates iodine electrochemically and reaches microgram levels, so it is used for very dry samples.
Solids are usually heated in an oven accessory, and the water vapour is carried by a dry gas stream into the titration cell. This avoids reaction between the sample matrix and the reagents and reduces interference from insoluble material.
Loss-on-drying measures any mass lost when the sample is heated, so volatile components such as alcohol or essential oils inflate the result. Karl Fischer titration measures water specifically through a chemical reaction and is preferred for oils and low-moisture products.
Halogen lamps heat rapidly and distribute energy evenly across the sample surface, shortening drying time and improving repeatability. They also allow the temperature to be controlled closely, which matters when a method specifies a drying temperature.
They are accurate for the crop and moisture range covered by their calibration, typically within about 0.5 percent. Accuracy falls for other crops, for very wet or very dry grain and at extreme temperatures, so reference oven drying should be used periodically.
Related models