Skip to main content
Lab Manufacturers China
Infrared Moisture Analyzer for Food — product photo

Infrared Moisture Analyzer for Food

食品红外水分分析仪

  • SKU MAN-0002
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Heating sourceInfrared lamp with reflector
Balance readability0.001 g
Maximum sample mass50–100 g
Moisture resolution0.01 percent
Temperature range50–180 °C
Heating profilesSingle or multi-step, programmable
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 712, ISO 6496, AOAC 925.10

What is the Infrared Moisture Analyzer for Food?

An infrared moisture analyzer uses a broad-spectrum infrared heater to dry food samples while weighing them continuously. It provides loss-on-drying results with gentler heating than halogen lamps, suiting temperature-sensitive powders and pastes.

What is the Infrared Moisture Analyzer for Food?

An infrared moisture analyzer uses a broad-spectrum infrared heater to dry food samples while weighing them continuously. It provides loss-on-drying results with gentler heating than halogen lamps, suiting temperature-sensitive powders and pastes.

Overview

The instrument mounts an infrared heater above a weighing pan inside an enclosed chamber. Radiant energy penetrates the surface layer and evaporates water, and the balance records mass loss until the endpoint criterion is met. Because heating is radiated rather than conducted, sample temperature rises more gradually than under a halogen lamp, which reduces scorching of sugars and browning of proteins. Some models use multiple heating profiles or a metal reflector to improve uniformity across the pan. Standard configurations offer 0.001 g readability, 0.01 percent moisture resolution and temperatures from 50 to 180 °C, with sample sizes of 1 to 20 g. Stored methods and printed reports make the instrument suitable for routine QC records.

How does it work?

Loss-on-drying instruments weigh a sample, heat it with an infrared or halogen lamp, and track mass until it stabilises; the mass loss is reported as moisture. Halogen lamps reach the drying temperature faster and distribute heat more evenly than infrared. Microwave drying drives water out from within the sample, which suits bulky or dense products. Capacitance meters in grain-moisture devices correlate the dielectric constant of a packed sample with water content using stored calibrations. Karl Fischer titration measures water chemically, by the iodine-sulfur dioxide reaction, and is the reference for low-moisture foods, oils and powders where volatiles would bias loss-on-drying. Vacuum oven drying remains the gravimetric reference method for many commodities.

What are the key features?

  • Broad-spectrum infrared heating with gentle temperature ramp
  • Multiple heating profiles for sensitive matrices
  • Balance readability of 0.001 g with 0.01 percent moisture
  • Reflector design for uniform heating across the pan
  • Stored product methods with endpoint criteria
  • Printed and exported results for QC records

What are the technical specifications?

A typical infrared moisture analyzer for food configuration offers heating source of Infrared lamp with reflector, balance readability of 0.001 g, maximum sample mass of 50–100 g, moisture resolution of 0.01 percent, temperature range of 50–180 °C and heating profiles of Single or multi-step, programmable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Infrared Moisture Analyzer for Food is used in heat-sensitive powder and spice moisture, confectionery and syrup intermediate control, meat and fish paste moisture checks and instant beverage and nutritional powder testing. Across the wider Moisture Analyzers class, laboratories also deploy it for grain intake moisture and safe storage decisions, nutrition labelling and dry-basis calculations and in-process control of drying and blending.

Which standards and certifications apply?

Relevant standards and methods include ISO 712, ISO 6496, AOAC 925.10, ISO 760, ASTM E203 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Moisture results depend on sample handling, so grinding, portion size, spreading and cooling time must follow the method. Loss-on-drying instruments need periodic verification with reference materials or a drying oven comparison, and the balance inside them should be checked with traceable weights. Karl Fischer reagents are moisture-sensitive and need fresh solvent, correct titration parameters and regular drift checks. Capacitance meters must be set to the right crop calibration and corrected for temperature. Keep records of reference-method comparisons and store instruments away from draughts, direct sunlight and heat sources.

How do I select the right Infrared Moisture Analyzer for Food?

Choose infrared heating when your products scorch easily or when a standard method specifies infrared drying. Confirm that the heating profile can be programmed and stored for each product, and verify results against oven drying for representative samples of every matrix you test.

How does it compare with other Moisture Analyzers variants?

Match the method to the product and to the accuracy you must report. Loss-on-drying analysers are fast and simple and are ideal for routine control of powders, pastes and liquids, but volatile components other than water can cause a positive bias. Halogen models heat faster and suit high sample numbers, while microwave models handle dense or bulky products better. Capacitance meters are convenient for grain at intake but depend on crop-specific calibrations and are affected by temperature. Karl Fischer titration is required for oils, low-moisture powders and any product where the reference method specifies it. Confirm repeatability, sample size and the ability to store and export results.

Full specifications

Full specifications
Heating sourceInfrared lamp with reflector
Balance readability0.001 g
Maximum sample mass50–100 g
Moisture resolution0.01 percent
Temperature range50–180 °C
Heating profilesSingle or multi-step, programmable
Drying time5–20 min typical
Endpoint modesAutomatic or timed
CalibrationExternal weights and reference material
InterfaceUSB, printer

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Heat-sensitive powder and spice moisture
  • Confectionery and syrup intermediate control
  • Meat and fish paste moisture checks
  • Instant beverage and nutritional powder testing

Key features

  • Broad-spectrum infrared heating with gentle temperature ramp
  • Multiple heating profiles for sensitive matrices
  • Balance readability of 0.001 g with 0.01 percent moisture
  • Reflector design for uniform heating across the pan
  • Stored product methods with endpoint criteria
  • Printed and exported results for QC records

Frequently asked questions about Infrared Moisture Analyzer for Food

Infrared heating is gentler and distributes radiant energy over a wider area, so browning and decomposition are reduced for sugar-rich foods. Halogen lamps heat faster and are often preferred when speed is the priority.

Request a quotation for the Infrared Moisture Analyzer for Food

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote