Robotic Liquid Handling Workstation for Clinical Laboratories
临床实验室机器人移液工作站
- SKU LAA-0005
- Laboratory Automation
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 quality system (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pipetting channels | 1, 4, 8 or 96 |
|---|---|
| Volume range | 1–1,000 µL |
| Accuracy | ≤ ±2% at 50–1,000 µL |
| Precision (CV) | ≤ 1.5% at mid-range volumes |
| Deck positions | 16–60 positions |
| Tip type | Disposable filter tips, 50/200/1,000 µL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI AUTO01, CLSI AUTO03, CLSI AUTO04
What is the Robotic Liquid Handling Workstation for Clinical Laboratories?
A robotic liquid handling workstation for clinical laboratories automates pipetting steps such as sample dilution, plate loading and nucleic acid extraction setup. It suits laboratories running open assays or molecular workflows that are not covered by closed analyzers.
What is the Robotic Liquid Handling Workstation for Clinical Laboratories?
A robotic liquid handling workstation for clinical laboratories automates pipetting steps such as sample dilution, plate loading and nucleic acid extraction setup. It suits laboratories running open assays or molecular workflows that are not covered by closed analyzers.
Overview
This variant is a deck-based robot with a multi-channel pipetting arm, often 1, 4, 8 or 96 channels, plus a gripper for moving plates and labware. The deck holds tube racks, tip boxes, reagent troughs and microplates, and liquid-level detection with clot detection supports reliable aspiration from primary tubes. Barcode readers identify samples and plates, and worklists from the LIS or a spreadsheet drive the method. Typical pipetting ranges are 1 to 1,000 µL with accuracy better than 2 percent at mid-range volumes. Common clinical uses include ELISA plate setup, serum dilution, PCR master mix preparation and nucleic acid extraction front-end. HEPA-filtered hoods and UV decontamination options reduce contamination risk in molecular workflows.
How does it work?
A laboratory automation system links modules through a transport layer, usually a conveyor track carrying individual tube carriers, or robotic arms and carts for smaller installations. Each carrier holds a tube that is identified by a barcode or RFID tag at input. Control software, often called middleware, queries the laboratory information system for the test orders, decides which instruments and modules the tube must visit, and routes it through decapping, centrifugation, aliquoting, analysis, resealing and storage. Sensors and cameras check tube type, cap, fill level and serum quality. Grippers handle tube formats of various diameters and lengths. Tracking data are logged, so each tube's location and status are always known, and urgent samples can be prioritized in the queue.
What are the key features?
- Multi-channel pipetting arm with liquid-level and clot detection
- Gripper for moving microplates, tube racks and labware on the deck
- Barcode identification of primary tubes, plates and reagents
- Disposable filter tips to limit carryover and cross-contamination
- Worklist import from LIS or spreadsheet with editable methods
- Optional HEPA enclosure and UV decontamination for molecular work
What are the technical specifications?
A typical robotic liquid handling workstation for clinical laboratories configuration offers pipetting channels of 1, 4, 8 or 96, volume range of 1–1,000 µL, accuracy of ≤ ±2% at 50–1,000 µL, precision (CV) of ≤ 1.5% at mid-range volumes, deck positions of 16–60 positions and tip type of Disposable filter tips, 50/200/1,000 µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Robotic Liquid Handling Workstation for Clinical Laboratories is used in ELISA and immunoassay plate setup, nucleic acid extraction preparation, PCR master mix dispensing and serial dilution of serum samples. Across the wider Laboratory Automation class, laboratories also deploy it for high-volume hospital laboratory workflows, reference laboratory specimen consolidation and emergency department STAT testing.
Which standards and certifications apply?
Relevant standards and methods include CLSI AUTO01, CLSI AUTO03, CLSI AUTO04, CLSI AUTO05, ISO 15189, IEC 61010-1, IEC 61010-2-101 and CLSI GP44. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Automation needs a level floor with adequate load rating, stable power with UPS backup, network connectivity and, where pneumatic modules are used, compressed air. Plan the layout for operator access and service clearance. Validate the installation through functional testing, carryover and sample identification checks, and verify interfaces with the LIS and each analyzer. Establish downtime procedures so that testing can continue manually if the track stops. Schedule preventive maintenance for belts, grippers and sensors, and clean carriers regularly. Follow biosafety practice for decapped tubes and aerosol control, and document validation under ISO 15189. Train staff on error recovery and on loading rules for tube types.
How do I select the right Robotic Liquid Handling Workstation for Clinical Laboratories?
Select a liquid handling workstation when open assays or molecular workflows require repetitive pipetting not covered by a closed analyzer. Specify channel count, volume range, sample tube formats, plate formats, contamination control, LIS or file-based worklists and required methods in the RFQ, and request validation data.
How does it compare with other Laboratory Automation variants?
Selection starts with daily tube volume, number of analyzers to connect and available floor plan. Small laboratories below a few hundred tubes per day may need only a pre-analytical module, while laboratories handling over 1,000 tubes benefit from a full track. Verify which analyzers the track can connect to, because open interfaces and third-party instrument support vary. Check tube formats and sizes, cap types, centrifuge capacity, urgent-sample handling, output buffer size and storage capacity. Confirm middleware functions such as rules-based routing, autoverification and reflex testing, and LIS interface protocols. Consider uptime, service response, spare parts, training, and the power, network and air requirements of the installation site.
Full specifications
| Pipetting channels | 1, 4, 8 or 96 |
|---|---|
| Volume range | 1–1,000 µL |
| Accuracy | ≤ ±2% at 50–1,000 µL |
| Precision (CV) | ≤ 1.5% at mid-range volumes |
| Deck positions | 16–60 positions |
| Tip type | Disposable filter tips, 50/200/1,000 µL |
| Liquid detection | Capacitive or pressure-based with clot detection |
| Plate formats | 96- and 384-well microplates |
| Sample throughput | Up to 200 samples per run |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- ELISA and immunoassay plate setup
- Nucleic acid extraction preparation
- PCR master mix dispensing
- Serial dilution of serum samples
Key features
- Multi-channel pipetting arm with liquid-level and clot detection
- Gripper for moving microplates, tube racks and labware on the deck
- Barcode identification of primary tubes, plates and reagents
- Disposable filter tips to limit carryover and cross-contamination
- Worklist import from LIS or spreadsheet with editable methods
- Optional HEPA enclosure and UV decontamination for molecular work
Frequently asked questions about Robotic Liquid Handling Workstation for Clinical Laboratories
Eight channels suit most clinical workflows such as ELISA plate loading and extraction setup, while a 96-channel head helps with high-throughput plate replication. Single-channel arms are adequate for low volumes of samples and method flexibility but are slower.
Disposable filter tips are replaced between samples, and methods use appropriate air gaps and tip eject locations. Molecular workflows add HEPA filtered enclosures, UV decontamination and separated pre- and post-amplification areas, verified by running blank wells between samples during validation.
Yes, laboratories verify pipetting accuracy and precision gravimetrically or photometrically, check carryover and confirm that the automated method reproduces results of the manual procedure. Documentation should follow the laboratory quality system under ISO 15189 and the regulatory status of the assay.
Total laboratory automation links pre-analytical, analytical and post-analytical modules with a transport track and control software so that tubes move from reception to storage with minimal manual handling. It typically includes sorting, decapping, centrifugation, aliquoting, analyzers, resealing and refrigerated storage.
There is no fixed threshold, but laboratories processing roughly 500 to 1,000 tubes per day or more, especially with several analyzers and staffing constraints, usually see benefits. Smaller laboratories may gain more from a stand-alone pre-analytical module than from a full track.
Some tracks use open interfaces and can connect to third-party analyzers through adapters or standardized tube carriers, while others are limited to specific analyzer families. Always confirm the list of validated connections and any software driver development needed before purchase.