Automated Refrigerated Sample Storage and Retrieval System

自动化冷藏样本存储与检索系统

  • SKU LAA-0003
  • Laboratory Automation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 13485 quality system (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Storage capacity2,000–20,000 tubes
Storage temperature2–8 °C
Temperature uniformity≤ ±2 °C
Retrieval time< 2 min per tube
Tube diameterØ 12–16 mm
Rack format5 × 10 or 10 × 10 positions
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI AUTO01, CLSI AUTO03, CLSI AUTO04

What is the Automated Refrigerated Sample Storage and Retrieval System?

An automated refrigerated sample storage and retrieval system stores capped specimen tubes at 2–8 °C in racks and retrieves them on demand for retesting or add-on tests. It is used by laboratories needing traceable, space-efficient archiving of post-analytical samples.

What is the Automated Refrigerated Sample Storage and Retrieval System?

An automated refrigerated sample storage and retrieval system stores capped specimen tubes at 2–8 °C in racks and retrieves them on demand for retesting or add-on tests. It is used by laboratories needing traceable, space-efficient archiving of post-analytical samples.

Overview

This variant is a cooled storage cabinet with a robotic picker that inserts and retrieves tubes or racks. Each tube is logged by barcode against a position, allowing retrieval by patient or accession number in under two minutes. Typical capacity ranges from 2,000 to 20,000 tubes, and the chamber holds 2–8 °C with a temperature alarm and data log. Some systems dispose of expired samples automatically by discarding them into a waste bin after the retention period, such as seven days. The unit can be linked to a track or used as a stand-alone device with manual loading. Compared with manual refrigerators it saves space, reduces search time and records who accessed which sample, which supports quality and audit requirements.

How does it work?

A laboratory automation system links modules through a transport layer, usually a conveyor track carrying individual tube carriers, or robotic arms and carts for smaller installations. Each carrier holds a tube that is identified by a barcode or RFID tag at input. Control software, often called middleware, queries the laboratory information system for the test orders, decides which instruments and modules the tube must visit, and routes it through decapping, centrifugation, aliquoting, analysis, resealing and storage. Sensors and cameras check tube type, cap, fill level and serum quality. Grippers handle tube formats of various diameters and lengths. Tracking data are logged, so each tube's location and status are always known, and urgent samples can be prioritized in the queue.

What are the key features?

  • Robotic picker that stores and retrieves tubes by barcode position
  • Chamber temperature maintained at 2–8 °C with alarm and data logging
  • Retrieval by patient or accession number within minutes
  • Automatic discard of expired samples after set retention period
  • Stand-alone use or connection to a laboratory automation track
  • Access logging that supports traceability and audit requirements

What are the technical specifications?

A typical automated refrigerated sample storage and retrieval system configuration offers storage capacity of 2,000–20,000 tubes, storage temperature of 2–8 °C, temperature uniformity of ≤ ±2 °C, retrieval time of < 2 min per tube, tube diameter of Ø 12–16 mm and rack format of 5 × 10 or 10 × 10 positions. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Refrigerated Sample Storage and Retrieval System is used in retest and add-on test retrieval, sample retention for quality audit, central laboratory archiving and blood center specimen storage. Across the wider Laboratory Automation class, laboratories also deploy it for high-volume hospital laboratory workflows, reference laboratory specimen consolidation and emergency department STAT testing.

Which standards and certifications apply?

Relevant standards and methods include CLSI AUTO01, CLSI AUTO03, CLSI AUTO04, CLSI AUTO05, ISO 15189, IEC 61010-1, IEC 61010-2-101 and CLSI GP44. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Automation needs a level floor with adequate load rating, stable power with UPS backup, network connectivity and, where pneumatic modules are used, compressed air. Plan the layout for operator access and service clearance. Validate the installation through functional testing, carryover and sample identification checks, and verify interfaces with the LIS and each analyzer. Establish downtime procedures so that testing can continue manually if the track stops. Schedule preventive maintenance for belts, grippers and sensors, and clean carriers regularly. Follow biosafety practice for decapped tubes and aerosol control, and document validation under ISO 15189. Train staff on error recovery and on loading rules for tube types.

How do I select the right Automated Refrigerated Sample Storage and Retrieval System?

Choose an automated storage system when retest requests are frequent and manual refrigerator searching consumes staff time. Specify storage capacity, retention days, tube formats, temperature range, stand-alone or track-connected operation, LIS interface and discard method in the RFQ.

How does it compare with other Laboratory Automation variants?

Selection starts with daily tube volume, number of analyzers to connect and available floor plan. Small laboratories below a few hundred tubes per day may need only a pre-analytical module, while laboratories handling over 1,000 tubes benefit from a full track. Verify which analyzers the track can connect to, because open interfaces and third-party instrument support vary. Check tube formats and sizes, cap types, centrifuge capacity, urgent-sample handling, output buffer size and storage capacity. Confirm middleware functions such as rules-based routing, autoverification and reflex testing, and LIS interface protocols. Consider uptime, service response, spare parts, training, and the power, network and air requirements of the installation site.

Full specifications

Full specifications
Storage capacity2,000–20,000 tubes
Storage temperature2–8 °C
Temperature uniformity≤ ±2 °C
Retrieval time< 2 min per tube
Tube diameterØ 12–16 mm
Rack format5 × 10 or 10 × 10 positions
Identification1D/2D barcode reader
Alarm functionsOver/under temperature, door open, power failure
Power supply220 V, 50/60 Hz, 1.5–3 kW
Footprint1.5–6 m²

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Retest and add-on test retrieval
  • Sample retention for quality audit
  • Central laboratory archiving
  • Blood center specimen storage

Key features

  • Robotic picker that stores and retrieves tubes by barcode position
  • Chamber temperature maintained at 2–8 °C with alarm and data logging
  • Retrieval by patient or accession number within minutes
  • Automatic discard of expired samples after set retention period
  • Stand-alone use or connection to a laboratory automation track
  • Access logging that supports traceability and audit requirements

Frequently asked questions about Automated Refrigerated Sample Storage and Retrieval System

Retention is set by laboratory policy and test stability, commonly seven days for routine chemistry and immunoassay specimens. Some tests require longer storage, so the system should allow different retention periods and freezer transfer for samples that must be kept longer.

Request a quotation for the Automated Refrigerated Sample Storage and Retrieval System