Ion Chromatograph for Cation Analysis in Water
水中阳离子分析用离子色谱仪
- SKU IOA-0003
- Ion Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Analytes | Li+, Na+, NH4+, K+, Mg2+, Ca2+ |
|---|---|
| Eluent | Methanesulfonic acid, 20–40 mmol/L |
| Flow rate | 0.5–1.5 mL/min |
| Injection volume | 10–50 µL |
| Detector | Conductivity (suppressed or non-suppressed) |
| Column oven | 30–40 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 10304-1, ISO 10304-2, EPA Method 300.1
What is the Ion Chromatograph for Cation Analysis in Water?
An ion chromatograph with a cation-exchange column, methanesulfonic acid eluent and suppressed or non-suppressed conductivity detection. It separates lithium, sodium, ammonium, potassium, magnesium and calcium in one run, supporting hardness, ammonium and cooling water chemistry testing in environmental and power plant laboratories.
What is the Ion Chromatograph for Cation Analysis in Water?
An ion chromatograph with a cation-exchange column, methanesulfonic acid eluent and suppressed or non-suppressed conductivity detection. It separates lithium, sodium, ammonium, potassium, magnesium and calcium in one run, supporting hardness, ammonium and cooling water chemistry testing in environmental and power plant laboratories.
Overview
This variant replaces the anion column, eluent and suppressor with a carboxylate- or sulfonate-based cation-exchange column and methanesulfonic acid eluent, usually at 20–30 mmol/L isocratic or with gradient to 40 mmol/L. Six common cations separate in about 12–20 minutes under ISO 14911. A cation suppressor or a non-suppressed conductivity design can be used, with detection limits around 5–50 µg/L. Ammonium is resolved from sodium and potassium, which is difficult with ISE in complex matrices. The configuration fits cooling water and power plant chemistry, where sodium and ammonium are tracked at low levels, and environmental water testing where calcium and magnesium define hardness. Many laboratories pair a cation and an anion channel on one dual-flow system, with a shared autosampler, to cut analysis time. Sample filtration and dilution are needed for high-hardness or high-ammonium samples.
How does it work?
Two technologies dominate. Ion-selective electrode (ISE) analyzers use a membrane that responds selectively to one ion, such as a LaF3 crystal for fluoride. The potential against a reference electrode follows the Nernst equation, changing about 59 mV per decade for monovalent ions at 25 °C, and concentration is found from calibration with standards and an ionic strength adjuster. Ion chromatography (IC) separates ions by injecting the sample onto an ion-exchange column, where an eluent such as carbonate-bicarbonate or hydroxide moves them at different rates. A suppressor reduces eluent background conductivity, and a conductivity detector records each ion as a peak whose retention time identifies it and whose area gives concentration. Autosamplers, eluent generators and chromatography software automate multi-ion runs.
What are the key features?
- Cation-exchange column separating Li, Na, NH4, K, Mg and Ca in one run
- Methanesulfonic acid eluent with optional electrolytic generation
- Suppressed or non-suppressed conductivity detection for ammonium at µg/L
- Dual-channel option pairs anion and cation analysis on a shared autosampler
- Column oven at 30–40 °C for stable retention of divalent cations
- Method templates for ISO 14911 and cooling water chemistry
What are the technical specifications?
A typical ion chromatograph for cation analysis in water configuration offers analytes of Li+, Na+, NH4+, K+, Mg2+, Ca2+, eluent of Methanesulfonic acid, 20–40 mmol/L, flow rate of 0.5–1.5 mL/min, injection volume of 10–50 µL, detector of Conductivity (suppressed or non-suppressed) and column oven of 30–40 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ion Chromatograph for Cation Analysis in Water is used in water hardness and ammonium determination, cooling water and boiler chemistry, groundwater and surface water surveys and fertilizer and soil extract analysis. Across the wider Ion Analyzers class, laboratories also deploy it for drinking water anion compliance testing, fluoride and nitrate monitoring and boiler and cooling water chemistry.
Which standards and certifications apply?
Relevant standards and methods include ISO 10304-1, ISO 10304-2, EPA Method 300.1, ASTM D4327, ASTM D1179, HJ 84, GB/T 5750.5 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
ISE systems need stable temperature, fresh standards and proper electrode conditioning, with slope checks in the 54–60 mV/decade range and membrane replacement when response slows. Ion chromatographs require deionized water of 18.2 MΩ·cm, filtered eluents degassed to avoid baseline noise, and sample filtration through 0.45 µm filters to protect the column. Keep guard columns in place and flush the system when storing. Calibrate with at least five standards and verify with a mid-range check standard each batch. Suppressors and columns have finite life, so track system pressure and retention times. Laboratories working to ISO/IEC 17025 should keep calibration records and control charts.
How do I select the right Ion Chromatograph for Cation Analysis in Water?
Choose the cation configuration when sodium, ammonium, potassium, magnesium and calcium must be reported together, particularly for cooling water or hardness work. Pair it with an anion channel if both panels are needed. In an RFQ, list cations and ranges, whether a dual-channel system is wanted, eluent generation preference, autosampler size and the reference method such as ISO 14911.
How does it compare with other Ion Analyzers variants?
The choice starts with how many ions you need and at what limit. For one or two ions such as fluoride or ammonium in routine samples, an ISE analyzer is fast and inexpensive. For simultaneous determination of chloride, nitrate, sulfate, phosphate and other anions, or cations like sodium, potassium and calcium, ion chromatography is required because it resolves interferences and gives full profiles at µg/L levels. Consider sample throughput and whether an autosampler is needed, as well as matrix complexity, since high-salt samples may require dilution or matrix elimination. Field work favors portable ISE meters, and continuous process control favors online analyzers with automated calibration. Confirm the reference method, such as ISO 10304-1 or HJ 84, and compare running costs for eluents, suppressors, columns and electrodes.
Full specifications
| Analytes | Li+, Na+, NH4+, K+, Mg2+, Ca2+ |
|---|---|
| Eluent | Methanesulfonic acid, 20–40 mmol/L |
| Flow rate | 0.5–1.5 mL/min |
| Injection volume | 10–50 µL |
| Detector | Conductivity (suppressed or non-suppressed) |
| Column oven | 30–40 °C |
| Detection limit | 5–50 µg/L |
| Linearity | R² ≥ 0.999 over 0.1–50 mg/L |
| Typical run time | 12–20 min |
| Autosampler capacity | 50–100 vials |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Water hardness and ammonium determination
- Cooling water and boiler chemistry
- Groundwater and surface water surveys
- Fertilizer and soil extract analysis
Key features
- Cation-exchange column separating Li, Na, NH4, K, Mg and Ca in one run
- Methanesulfonic acid eluent with optional electrolytic generation
- Suppressed or non-suppressed conductivity detection for ammonium at µg/L
- Dual-channel option pairs anion and cation analysis on a shared autosampler
- Column oven at 30–40 °C for stable retention of divalent cations
- Method templates for ISO 14911 and cooling water chemistry
Frequently asked questions about Ion Chromatograph for Cation Analysis in Water
IC measures ammonium together with sodium, potassium, magnesium and calcium in one run and avoids the color, turbidity and reagent interferences that affect colorimetric methods. Colorimetry remains simpler and cheaper for single-parameter ammonia nitrogen testing.
Sodium and ammonium elute close together on many columns, and a large excess of one can mask the other. A high-capacity column, lower eluent strength or sample dilution improves resolution. Verify separation with a mixed standard at matrix-like ratios.
Yes. IC gives calcium and magnesium separately, and total hardness is calculated from them as mg/L CaCO3. It avoids the endpoint judgment of EDTA titration, but samples with high hardness must be diluted so peaks stay within the calibration range.
An ion-selective electrode responds to one ion and is fast and economical for single-ion routine tests. Ion chromatography separates many ions in one run, gives full anion or cation profiles at lower limits, and resists many matrix interferences, but costs more and needs eluents and skilled operation.
Common anions are fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate, run under ISO 10304-1 or EPA 300.1. With a cation column it also measures lithium, sodium, ammonium, potassium, magnesium and calcium. Bromate and other disinfection by-products need a dedicated method.
An electrode responds to ion activity, not concentration. Adding an ionic strength adjuster, such as TISAB for fluoride, fixes the total ionic strength of samples and standards so activity coefficients are constant, letting the measured potential correlate directly with concentration. It also controls pH and masks complexing interferents.