High-Temperature Drying Oven
高温干燥箱
- SKU HTO-0001
- High Temperature Ovens
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–500 L |
|---|---|
| Temperature range | RT+10 to 500 C |
| Temperature uniformity | ±3–6 C |
| Thermocouple type | Type K or N |
| Insulation material | Ceramic fiber board |
| Heat-up time to 400 C | 40–80 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880
What is the High-Temperature Drying Oven?
A high-temperature drying oven works from about 300 to 500 C to dry ceramics, metals, glass and coatings that a standard oven cannot process. It is chosen when residual moisture or binder must be removed at high heat.
What is the High-Temperature Drying Oven?
A high-temperature drying oven works from about 300 to 500 C to dry ceramics, metals, glass and coatings that a standard oven cannot process. It is chosen when residual moisture or binder must be removed at high heat.
Overview
This oven extends the drying chamber into the high-temperature range with thicker ceramic fiber insulation, high-duty elements and heat-resistant door seals. Air circulation is retained to keep gradients small, and fans are rated for the hot zone or externally mounted. Capacity ranges from about 50 to 500 liters, with shelves of stainless steel or heat-resistant alloy. Temperature uniformity is typically plus or minus 3 to 6 C and loosens near the top of the range, where thermal losses grow. A PID controller with a type K or N thermocouple and an independent over-temperature limiter are standard, and some models include programmable profiles and extraction ports.
How does it work?
A high-temperature oven extends the forced air or gravity design to higher setpoints using high-duty heating elements, thicker insulation and materials rated for continuous heat. Elements placed in the walls or ducts operate at higher surface temperature, and insulation uses ceramic fiber or mineral wool boards instead of low-density wool. Air circulation is often retained to flatten gradients, but fans and motors must be rated for the hot zone or mounted outside it. Door seals are heat-resistant silicone or ceramic rope, and the exterior is cooled by an air gap or cooling fan to protect controls. A PID controller with type K or N thermocouple holds the setpoint, and an independent over-temperature limiter protects the load and the chamber structure.
What are the key features?
- Working range of 300 to 500 C
- Thick ceramic fiber or mineral wool insulation
- High-duty elements in walls or air ducts
- Heat-resistant door seal with external cooling
- PID controller with type K or N thermocouple
- Extraction port for fume removal
What are the technical specifications?
A typical high-temperature drying oven configuration offers chamber volume of 50–500 L, temperature range of RT+10 to 500 C, temperature uniformity of ±3–6 C, thermocouple type of Type K or N, insulation material of Ceramic fiber board and heat-up time to 400 C of 40–80 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Temperature Drying Oven is used in ceramic and glass drying, metal part preheating, coating and binder removal and inorganic sample preparation. Across the wider High Temperature Ovens class, laboratories also deploy it for burn-off cleaning of metal parts, high-temperature curing of coatings and dry-heat sterilization at 250 to 300 C.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 9001 and GB/T 30435. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a heat-resistant surface with clearance for the hot exterior and cooling air. Provide local extraction when fume-producing materials are processed, and never heat sealed containers or flammable solvents. Allow long, controlled warm-up and a slow cooling stage to avoid thermal stress on the chamber and load. Calibrate the temperature sensor regularly and map uniformity across the range, since gradients widen near the top temperature. Inspect elements, seals and insulation periodically for cracks or discoloration, replace damaged parts before failure, and record all service and temperature checks.
How do I select the right High-Temperature Drying Oven?
Select the high-temperature drying oven when the process needs 300 to 500 C and throughput is moderate. Standard ovens are cheaper below 300 C, and furnaces are used above 600 C. In the RFQ, specify maximum temperature, uniformity at setpoint, volume, atmosphere, extraction and power supply.
How does it compare with other High Temperature Ovens variants?
Choose a high-temperature oven only when the working temperature genuinely exceeds about 300 C, since standard ovens are cheaper and more uniform below that. Set the maximum temperature with a margin above the working setpoint and check the material of the load, because many polymers and coatings degrade and release fumes. Decide between gravity and forced circulation, and confirm that the fan and seals are rated for the top temperature. Specify insulation grade, exterior cooling, door type and controller features. For burn-off cleaning, check fume extraction and residue management. Confirm electrical supply, since three-phase power is common above 4 kW.
Full specifications
| Chamber volume | 50–500 L |
|---|---|
| Temperature range | RT+10 to 500 C |
| Temperature uniformity | ±3–6 C |
| Thermocouple type | Type K or N |
| Insulation material | Ceramic fiber board |
| Heat-up time to 400 C | 40–80 min |
| Timer range | 1–9999 min |
| Heating power | 3–9 kW |
| Interior material | 304 stainless steel or heat-resistant alloy |
| Power supply | 380 V, 3-phase, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Ceramic and glass drying
- Metal part preheating
- Coating and binder removal
- Inorganic sample preparation
Key features
- Working range of 300 to 500 C
- Thick ceramic fiber or mineral wool insulation
- High-duty elements in walls or air ducts
- Heat-resistant door seal with external cooling
- PID controller with type K or N thermocouple
- Extraction port for fume removal
Frequently asked questions about High-Temperature Drying Oven
It dries and conditions ceramics, metals, glass and inorganic materials at 300 to 500 C, removing moisture and binders that standard ovens cannot drive off. It is common in materials, electronics and ceramics laboratories, with extraction for any fumes produced.
Heat loss through walls and the door increases sharply with temperature, and element and airflow capacity are finite, so gradients widen near the top of the range. Testing uniformity at the actual working setpoint rather than a midpoint gives a realistic figure.
Models above about 4 kW generally require 380 V three-phase supply, with dedicated protection and cabling sized for continuous load. Confirm the available supply and earthing before installation, since upgrading power later is costly.
Most models cover 300 to 500 C, with specialized units reaching 600 C. They bridge the gap between standard drying ovens, which stop near 250 to 300 C, and muffle furnaces, which start around 1000 C.
It heats metal parts, fixtures and filters to 400 to 500 C to burn away organic residues such as oils, polymers and coatings, leaving a clean surface. Fume extraction and controlled heating are essential to avoid flare-ups and to remove combustion products safely.
High-duty resistance wire and tubular elements are used to about 500 to 600 C, placed in walls or ducts so they are protected from drips. Elements are sized for higher surface temperature and longer life, and fans are rated for the hot zone or mounted outside it.