Bio-Inert HPLC System — product photo

Bio-Inert HPLC System

生物惰性高效液相色谱系统

  • SKU HPL-0005
  • HPLC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wetted materialsTitanium, PEEK, ceramic, MP35N
Flow rate range0.01–5 mL/min
Maximum operating pressure40–60 MPa (400–600 bar)
Operating pH range1–14
Gradient composition accuracy±0.5–1% absolute
Autosampler temperature control4–40 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, Ph. Eur. 2.2.29, USP <1058>

What is the Bio-Inert HPLC System?

A bio-inert HPLC system replaces stainless-steel wetted parts with titanium, PEEK, ceramic or MP35N alloy so that high-salt buffers, extreme pH and metal-sensitive biomolecules do not corrode the flow path or adsorb onto it. It is used for proteins, antibodies, oligonucleotides and ion-exchange or size-exclusion methods.

What is the Bio-Inert HPLC System?

A bio-inert HPLC system replaces stainless-steel wetted parts with titanium, PEEK, ceramic or MP35N alloy so that high-salt buffers, extreme pH and metal-sensitive biomolecules do not corrode the flow path or adsorb onto it. It is used for proteins, antibodies, oligonucleotides and ion-exchange or size-exclusion methods.

Overview

Standard stainless-steel flow paths can corrode in chloride-rich buffers and can bind proteins, phosphorylated compounds and oligonucleotides through metal interactions. Bio-inert systems use metal-free or passivated fluid paths, with pump heads and valves in titanium or ceramic, and capillaries and fittings in PEEK or coated metal. They typically operate at 0–600 bar and pH 1–14, allowing phosphate, high-concentration sodium chloride and ammonium sulfate gradients. Typical modules include a quaternary or binary pump, a thermostatted autosampler, a column compartment and UV or fluorescence detection at 214, 260 and 280 nm. Size-exclusion chromatography of monoclonal antibody aggregates, ion-exchange charge variant analysis and hydrophobic interaction chromatography are common applications. Buffer salts must still be rinsed out after use, even with inert materials, to preserve seals and columns.

How does it work?

An HPLC system pumps solvent through an injector and a packed column, typically 50–250 mm long with 3–5 µm particles. The sample is injected as a narrow band and analytes partition between the mobile phase and the stationary phase, most commonly bonded C18 silica in reversed-phase mode. Retention depends on polarity, pH, temperature and solvent strength. Isocratic operation keeps composition constant; gradient operation changes it over time to elute compounds with widely different retention. Key modules are the solvent delivery pump with degasser, the autosampler, the thermostatted column compartment and the detector, commonly UV-Vis, diode-array, fluorescence or refractive index. Chromatography data software integrates peaks, applies calibration curves and reports retention time, area, plate count and tailing factor for system suitability.

What are the key features?

  • Metal-free or passivated flow path using titanium, PEEK, ceramic and MP35N components
  • Tolerates pH 1–14 and salt concentrations up to saturated sodium chloride or ammonium sulfate
  • Thermostatted autosampler at 4 °C protecting proteins and oligonucleotides from degradation
  • UV and fluorescence detection at 214, 260 and 280 nm for protein and nucleic acid work
  • Compatible with SEC, IEX, HIC and reversed-phase protein columns, including wide-pore media

What are the technical specifications?

A typical bio-inert hplc system configuration offers wetted materials of Titanium, PEEK, ceramic, MP35N, flow rate range of 0.01–5 mL/min, maximum operating pressure of 40–60 MPa (400–600 bar), operating pH range of 1–14, gradient composition accuracy of ±0.5–1% absolute and autosampler temperature control of 4–40 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Bio-Inert HPLC System is used in monoclonal antibody aggregate analysis by SEC, charge variant analysis by ion exchange, oligonucleotide and nucleic acid analysis, phosphopeptide and metal-sensitive compound analysis and high-salt buffer methods. Across the wider HPLC class, laboratories also deploy it for assay and purity testing of drug substances, food additive and vitamin analysis and environmental pollutant monitoring.

Which standards and certifications apply?

Relevant standards and methods include USP <621>, Ph. Eur. 2.2.29, USP <1058>, ICH Q2(R2), ChP 0512, IEC 61010-1, ISO/IEC 17025 and 21 CFR Part 11. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system on a stable bench away from drafts, with a steady power supply and ventilated solvent waste storage. Degas and filter mobile phases through 0.22–0.45 µm membranes to protect check valves and columns. Qualify the instrument (IQ/OQ/PQ) following USP <1058>, verifying flow accuracy, gradient composition accuracy, injection precision, detector linearity, wavelength accuracy and column oven temperature. Establish preventive maintenance for pump seals, piston washes, lamps and autosampler needle seats. Flush buffers with water before storing, and follow column manufacturer pH and pressure limits. For regulated work, configure audit trails and user roles in the data system.

How do I select the right Bio-Inert HPLC System?

Select a bio-inert system when methods use chloride or other corrosive buffers, extreme pH, or when analytes adsorb on stainless steel. A standard system is adequate for small-molecule reversed-phase work. In an RFQ list wetted materials, pH range, pressure rating, autosampler cooling, detector wavelengths and whether SEC, IEX or HIC columns will be used.

How does it compare with other HPLC variants?

Within a chromatography laboratory, HPLC configurations differ mainly in pump design, detector options and scale. Isocratic systems suit single-solvent routine assays at the lowest cost. Binary gradient systems cover most method development and impurity work, while quaternary systems add on-line solvent blending for screening and pH or modifier adjustment. Preparative systems are chosen when the goal is to isolate milligrams to grams of a compound, and bio-inert systems are needed when mobile phases contain high salt or extreme pH, or when proteins must not contact stainless steel. Decide on maximum pressure, flow range, dwell volume, autosampler capacity, detector types, column oven range and data-integrity features. Check that column dimensions in your validated methods are supported without extensive re-plumbing.

Full specifications

Full specifications
Wetted materialsTitanium, PEEK, ceramic, MP35N
Flow rate range0.01–5 mL/min
Maximum operating pressure40–60 MPa (400–600 bar)
Operating pH range1–14
Gradient composition accuracy±0.5–1% absolute
Autosampler temperature control4–40 °C
Injection volume0.1–100 µL
Column oven range5–80 °C
Detector wavelength range190–700 nm (UV), FLD optional
Injection carryover≤0.05%

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Monoclonal antibody aggregate analysis by SEC
  • Charge variant analysis by ion exchange
  • Oligonucleotide and nucleic acid analysis
  • Phosphopeptide and metal-sensitive compound analysis
  • High-salt buffer methods

Key features

  • Metal-free or passivated flow path using titanium, PEEK, ceramic and MP35N components
  • Tolerates pH 1–14 and salt concentrations up to saturated sodium chloride or ammonium sulfate
  • Thermostatted autosampler at 4 °C protecting proteins and oligonucleotides from degradation
  • UV and fluorescence detection at 214, 260 and 280 nm for protein and nucleic acid work
  • Compatible with SEC, IEX, HIC and reversed-phase protein columns, including wide-pore media

Frequently asked questions about Bio-Inert HPLC System

Stainless steel can release iron and chromium ions and corrode in chloride-rich buffers, and its surface can bind phosphorylated peptides, oligonucleotides and some proteins. This causes peak tailing, poor recovery and baseline artifacts. Bio-inert materials such as titanium and PEEK reduce these interactions.

Related models

All HPLC
Preparative HPLC System — product photo

Preparative HPLC System

制备型高效液相色谱系统

  • CE (to be confirmed)
  • +2
Request a quote
Binary UHPLC System — product photo

Binary UHPLC System

二元超高效液相色谱系统

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Bio-Inert HPLC System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote