Quaternary Gradient HPLC System

四元梯度高效液相色谱系统

  • SKU HPL-0003
  • HPLC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Flow rate range0.05–10 mL/min
Maximum operating pressure40–60 MPa (400–600 bar)
Solvent channels4
Gradient composition accuracy±1% absolute
Gradient composition precision (RSD)≤0.2%
Dwell volume600–1000 µL
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <621>, Ph. Eur. 2.2.29, USP <1058>

What is the Quaternary Gradient HPLC System?

A quaternary gradient HPLC system blends up to four solvents on the low-pressure side of a single pump using a proportioning valve. It is the preferred configuration for method development laboratories that screen buffers, pH values and organic modifiers without physically changing solvent bottles between runs.

What is the Quaternary Gradient HPLC System?

A quaternary gradient HPLC system blends up to four solvents on the low-pressure side of a single pump using a proportioning valve. It is the preferred configuration for method development laboratories that screen buffers, pH values and organic modifiers without physically changing solvent bottles between runs.

Overview

Quaternary systems use a low-pressure proportioning valve that rapidly switches between four solvent lines before a single high-pressure pump, with an in-line vacuum degasser for each channel. Dwell volume is larger than in binary designs, typically 600–1000 µL, which broadens gradients slightly but is acceptable for most 4.6 mm column work. The main benefit is flexibility: a chemist can scan pH by blending two buffers, change organic modifier ratios, and run automated column and solvent screening with software-controlled method sequences. Pressure ratings are typically 400–600 bar, and flow ranges of 0.05–10 mL/min suit analytical columns. Low-pressure mixing is slightly less precise at very low percentages of a channel, so additives at under 1% should be premixed. Maintenance of the proportioning valve and degasser membranes should be scheduled to preserve composition accuracy.

How does it work?

An HPLC system pumps solvent through an injector and a packed column, typically 50–250 mm long with 3–5 µm particles. The sample is injected as a narrow band and analytes partition between the mobile phase and the stationary phase, most commonly bonded C18 silica in reversed-phase mode. Retention depends on polarity, pH, temperature and solvent strength. Isocratic operation keeps composition constant; gradient operation changes it over time to elute compounds with widely different retention. Key modules are the solvent delivery pump with degasser, the autosampler, the thermostatted column compartment and the detector, commonly UV-Vis, diode-array, fluorescence or refractive index. Chromatography data software integrates peaks, applies calibration curves and reports retention time, area, plate count and tailing factor for system suitability.

What are the key features?

  • Low-pressure proportioning valve blending up to four solvents from one pump
  • Four-channel vacuum degasser with low internal volume to prevent bubble formation
  • Automated scouting of pH, buffer strength and organic modifier through software sequences
  • Flow range 0.05–10 mL/min suitable for 2.1–4.6 mm analytical columns
  • Optional multi-column selector valve enabling unattended screening of up to six columns

What are the technical specifications?

A typical quaternary gradient hplc system configuration offers flow rate range of 0.05–10 mL/min, maximum operating pressure of 40–60 MPa (400–600 bar), solvent channels of 4, gradient composition accuracy of ±1% absolute, gradient composition precision (RSD) of ≤0.2% and dwell volume of 600–1000 µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Quaternary Gradient HPLC System is used in pH and buffer scouting in method development, column and solvent screening, multi-solvent pharmaceutical assays and research laboratories with varied methods. Across the wider HPLC class, laboratories also deploy it for assay and purity testing of drug substances, food additive and vitamin analysis and environmental pollutant monitoring.

Which standards and certifications apply?

Relevant standards and methods include USP <621>, Ph. Eur. 2.2.29, USP <1058>, ICH Q2(R2), ChP 0512, IEC 61010-1, ISO/IEC 17025 and 21 CFR Part 11. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system on a stable bench away from drafts, with a steady power supply and ventilated solvent waste storage. Degas and filter mobile phases through 0.22–0.45 µm membranes to protect check valves and columns. Qualify the instrument (IQ/OQ/PQ) following USP <1058>, verifying flow accuracy, gradient composition accuracy, injection precision, detector linearity, wavelength accuracy and column oven temperature. Establish preventive maintenance for pump seals, piston washes, lamps and autosampler needle seats. Flush buffers with water before storing, and follow column manufacturer pH and pressure limits. For regulated work, configure audit trails and user roles in the data system.

How do I select the right Quaternary Gradient HPLC System?

Select a quaternary system when one instrument must serve many methods or when scouting is routine. Prefer binary if your work is dominated by fast gradients or UHPLC-style methods that are sensitive to dwell volume. In an RFQ specify channel count, degasser type, pressure rating, column selector needs, detector set and method-screening software.

How does it compare with other HPLC variants?

Within a chromatography laboratory, HPLC configurations differ mainly in pump design, detector options and scale. Isocratic systems suit single-solvent routine assays at the lowest cost. Binary gradient systems cover most method development and impurity work, while quaternary systems add on-line solvent blending for screening and pH or modifier adjustment. Preparative systems are chosen when the goal is to isolate milligrams to grams of a compound, and bio-inert systems are needed when mobile phases contain high salt or extreme pH, or when proteins must not contact stainless steel. Decide on maximum pressure, flow range, dwell volume, autosampler capacity, detector types, column oven range and data-integrity features. Check that column dimensions in your validated methods are supported without extensive re-plumbing.

Full specifications

Full specifications
Flow rate range0.05–10 mL/min
Maximum operating pressure40–60 MPa (400–600 bar)
Solvent channels4
Gradient composition accuracy±1% absolute
Gradient composition precision (RSD)≤0.2%
Dwell volume600–1000 µL
Degasser channel volume≤ 1 mL per channel
Autosampler capacity100–250 vials
Column oven temperature range5–85 °C
Detector optionsDAD, VWD, FLD, RID, ELSD

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • pH and buffer scouting in method development
  • Column and solvent screening
  • Multi-solvent pharmaceutical assays
  • Research laboratories with varied methods

Key features

  • Low-pressure proportioning valve blending up to four solvents from one pump
  • Four-channel vacuum degasser with low internal volume to prevent bubble formation
  • Automated scouting of pH, buffer strength and organic modifier through software sequences
  • Flow range 0.05–10 mL/min suitable for 2.1–4.6 mm analytical columns
  • Optional multi-column selector valve enabling unattended screening of up to six columns

Frequently asked questions about Quaternary Gradient HPLC System

Solvents are mixed at low pressure before the pump head, so the mixing volume, the pump chambers and the downstream mixer all sit between the blend point and the column. This adds volume compared with high-pressure binary mixing, where streams merge immediately ahead of the column.

Related models

All HPLC
Preparative HPLC System — product photo

Preparative HPLC System

制备型高效液相色谱系统

  • CE (to be confirmed)
  • +2
Request a quote
Bio-Inert HPLC System — product photo

Bio-Inert HPLC System

生物惰性高效液相色谱系统

  • CE (to be confirmed)
  • +2
Request a quote
Micro-Flow UHPLC System — product photo

Micro-Flow UHPLC System

微流量超高效液相色谱系统

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Quaternary Gradient HPLC System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote