Benchtop Flow Cytometer
台式流式细胞仪
- SKU FCY-0001
- Flow Cytometers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Laser configuration | 1–3 (488 nm; optional 405/640 nm) |
|---|---|
| Fluorescence channels | 4–10 |
| Scatter parameters | FSC, SSC |
| Maximum event rate | Up to 35,000 events/s |
| Sample flow rate | Approx. 10–120 µL/min |
| Fluorescence sensitivity | FITC below 100 MESF (typical) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-1
What is the Benchtop Flow Cytometer?
A benchtop flow cytometer is a compact, filter-based analyzer with one to three lasers and roughly 4 to 10 fluorescence channels. It is the standard choice for routine immunophenotyping, cell cycle and apoptosis assays where panel complexity is moderate and bench space is limited.
What is the Benchtop Flow Cytometer?
A benchtop flow cytometer is a compact, filter-based analyzer with one to three lasers and roughly 4 to 10 fluorescence channels. It is the standard choice for routine immunophenotyping, cell cycle and apoptosis assays where panel complexity is moderate and bench space is limited.
Overview
The benchtop flow cytometer integrates fluidics, optics and electronics in a single chassis that fits on a standard laboratory bench. Typical configurations use a 488 nm blue laser, optionally with 633 or 640 nm red and 405 nm violet lasers, and filter-based detection of forward scatter, side scatter and four to ten fluorescence parameters. Hydrodynamic focusing with pressure-driven fluidics supports event rates up to about 10,000 to 35,000 events per second. Automated startup, cleaning and daily quality control routines reduce operator time, and acquisition software supports compensation, templates and batch export in FCS 3.1 format. These instruments cover the majority of clinical and academic assays, such as lymphocyte subsets, DNA content, viability and GFP expression, but offer less flexibility for high-dimensional panels than research analyzers.
How does it work?
A flow cytometer uses sheath fluid to hydrodynamically focus a sample into a narrow core stream so cells cross the laser interrogation point one at a time. Scattered light is collected at small angles (forward scatter, related to size) and at 90 degrees (side scatter, related to granularity). Fluorochromes are excited by lasers, commonly 405, 488, 561 and 640 nm, and emission is split by dichroic filters and bandpass filters to photomultiplier tubes or photodiodes. Conventional instruments assign one detector per fluorochrome and apply a compensation matrix, whereas spectral instruments capture the full emission spectrum and unmix it mathematically. Electronics digitize pulse height, area and width, and software records list-mode FCS files for gating and statistical analysis.
What are the key features?
- Compact single-chassis design fits a standard laboratory bench without an external compressor
- One to three lasers with filter-based detection of up to 10 fluorescence channels
- Automated startup, shutdown and cleaning cycles reduce hands-on operator time
- Acquisition rates up to about 35,000 events per second for routine samples
- Template-driven acquisition software with compensation and FCS 3.1 export
- Bead-based daily quality control routine for laser and detector verification
What are the technical specifications?
A typical benchtop flow cytometer configuration offers laser configuration of 1–3 (488 nm; optional 405/640 nm), fluorescence channels of 4–10, scatter parameters of FSC, SSC, maximum event rate of Up to 35,000 events/s, sample flow rate of Approx. 10–120 µL/min and fluorescence sensitivity of FITC below 100 MESF (typical). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Flow Cytometer is used in lymphocyte subset immunophenotyping, cell cycle analysis by DNA content, apoptosis and viability assays, GFP and transfection efficiency and academic core-facility analysis. Across the wider Flow Cytometers class, laboratories also deploy it for immunophenotyping of lymphocyte subsets, CD34 stem cell enumeration and cell cycle and apoptosis analysis.
Which standards and certifications apply?
Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-1, IEC 61010-1, IEC 61010-2-101, IEC 60825-1 and ISAC FCS 3.1. Certification candidates for this model are CE, ISO 13485 manufacturing and IEC 61010-1 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the cytometer on a vibration-free bench with stable power and ambient temperature between 15 and 30 degrees Celsius, and provide waste handling for potentially biohazardous effluent, typically with bleach treatment. Run daily quality control using fluorescent beads to verify laser alignment, sensitivity and coefficient of variation, and keep Levey-Jennings style records of detector voltages. Perform daily and weekly fluidics cleaning to avoid clogging, and replace sheath filters and tubing on schedule. Laser power and optical alignment should be checked by trained service staff at least annually. Laboratories working under ISO 15189 or GLP should enable audit trails, electronic signatures and validated software updates.
How do I select the right Benchtop Flow Cytometer?
Choose a benchtop cytometer for routine panels up to about 8 colors, moderate throughput and limited bench space. For larger panels or rare-event detection, move to a high-parameter analyzer. In an RFQ specify laser wavelengths, channel count, event rate, software features such as audit trail, required IVD registration and the service support available locally.
How does it compare with other Flow Cytometers variants?
Select a cytometer by panel complexity, sensitivity and workflow. Define the maximum number of simultaneous colors, then choose laser and detector count to match; conventional filter-based systems are simple for 4 to 12 colors, while spectral systems ease panel design beyond 20. Check resolution of dim populations, small particle detection and event rate, typically 10,000 to 100,000 events per second. Consider footprint, whether a compact personal analyzer or a full research platform is required, and whether an acoustic focusing or plate loader is needed for throughput. Verify that software provides compensation or unmixing, batch analysis and user access control. For clinical use, confirm that the supplier can support IVD documentation, calibration beads and a validated quality control routine.
Full specifications
| Laser configuration | 1–3 (488 nm; optional 405/640 nm) |
|---|---|
| Fluorescence channels | 4–10 |
| Scatter parameters | FSC, SSC |
| Maximum event rate | Up to 35,000 events/s |
| Sample flow rate | Approx. 10–120 µL/min |
| Fluorescence sensitivity | FITC below 100 MESF (typical) |
| Carry-over | Below 1% |
| Data format | FCS 3.1 |
| Footprint | Approx. 50 × 60 × 55 cm |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lymphocyte subset immunophenotyping
- Cell cycle analysis by DNA content
- Apoptosis and viability assays
- GFP and transfection efficiency
- Academic core-facility analysis
Key features
- Compact single-chassis design fits a standard laboratory bench without an external compressor
- One to three lasers with filter-based detection of up to 10 fluorescence channels
- Automated startup, shutdown and cleaning cycles reduce hands-on operator time
- Acquisition rates up to about 35,000 events per second for routine samples
- Template-driven acquisition software with compensation and FCS 3.1 export
- Bead-based daily quality control routine for laser and detector verification
Frequently asked questions about Benchtop Flow Cytometer
Most benchtop models detect between four and ten fluorescence colors, depending on whether one, two or three lasers are installed. Practical panel size is also limited by spectral overlap, fluorochrome brightness and the filter set fitted to each detector.
A typical tube run needs 100 to 500 microliters of cell suspension at about one million cells per milliliter, with a dead volume of roughly 50 to 100 microliters. Low flow rates of 10 to 60 microliters per minute are used for fine resolution of DNA histograms.
Some models allow field-installable laser and detector upgrades, but many are fixed at purchase because the optical bench is pre-aligned. Confirm upgrade options and cost with the supplier before buying if you expect your panels to grow.
A flow cytometer measures forward scatter, side scatter and fluorescence intensity from each cell or particle. These signals report relative size, internal complexity and the presence or amount of fluorescently labeled markers, enabling counting, phenotyping and functional analysis at rates of thousands of cells per second.
Conventional cytometers use optical filters to direct a defined wavelength band to each detector and then compensate for overlap. Spectral cytometers record the whole emission spectrum across many detectors and unmix it, which allows more colors per panel and use of autofluorescence extraction.
Run quality control with fluorescent calibration beads every day of use to confirm laser alignment, sensitivity and stability. Full preventive maintenance by a trained engineer, including laser power and optical alignment verification, is normally performed once or twice a year.