Benchtop Cell Sorter
台式细胞分选仪
- SKU CSO-0002
- Cell Sorters
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Laser configuration | 2–4 (405/488/561/640 nm) |
|---|---|
| Fluorescence channels | 6–14 |
| Sort streams | 2 or 4-way |
| Nozzle size | 70–100 µm |
| Maximum sort rate | Up to 25,000 events/s |
| Sort purity | Above 95% (typical) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISAC Cell Sorter Biosafety Standards, IEC 61010-1, IEC 60825-1
What is the Benchtop Cell Sorter?
A benchtop cell sorter is a compact droplet or chip-based sorter with two to four lasers and two-way to four-way sorting. It gives individual laboratories in-house access to routine sorting, cloning and enrichment without the space, gas and staffing demands of a full core-facility system.
What is the Benchtop Cell Sorter?
A benchtop cell sorter is a compact droplet or chip-based sorter with two to four lasers and two-way to four-way sorting. It gives individual laboratories in-house access to routine sorting, cloning and enrichment without the space, gas and staffing demands of a full core-facility system.
Overview
Benchtop sorters condense optics, fluidics and sort module into an instrument of roughly 100 centimeters width that can be placed in a laboratory or inside a biosafety cabinet. They typically use two to four lasers, six to 14 fluorescence channels, and a fixed nozzle of 70 to 100 micrometers or a disposable sort cartridge. Sort speeds are commonly 5,000 to 25,000 events per second for routine two-way or four-way sorts. Simplified startup and automated alignment reduce operator skill requirements, and pre-configured sort templates help labs begin quickly. Many systems include integrated aerosol management or are designed to fit in a biosafety cabinet. Compared with high-speed systems, they have fewer colors, lower top speeds and less configuration flexibility, but they suit routine workflows such as GFP-positive enrichment, immune cell subsets and clonal cell line development.
How does it work?
Sorters analyze cells like an analyzer, then apply a decision in real time. In droplet sorters, a piezoelectric transducer vibrates the nozzle at 20 to 100 kHz so the stream breaks into uniform droplets just after the laser intercept. When a cell matching the sort gate is about to be enclosed, the electronics apply a charge to the stream, and the droplet separates carrying that charge. Charged droplets pass through high-voltage deflection plates and fall into tubes or multiwell plates, while uncharged droplets go to waste. A drop delay calibrated with fluorescent beads defines the time between detection and droplet break-off. Microfluidic chip sorters instead use valves, piezo actuators or optical forces inside a disposable cartridge, enclosing the sample away from aerosols.
What are the key features?
- Compact footprint suitable for placement inside or beside a biosafety cabinet
- Two to four lasers with six to 14 fluorescence channels
- Automated alignment and drop delay setup shortens daily start time
- Two-way or four-way sorting into tubes or multiwell plates
- Integrated aerosol management option for sorting human or infectious samples
- Pre-configured sort templates for routine enrichment and single-cell cloning
What are the technical specifications?
A typical benchtop cell sorter configuration offers laser configuration of 2–4 (405/488/561/640 nm), fluorescence channels of 6–14, sort streams of 2 or 4-way, nozzle size of 70–100 µm, maximum sort rate of Up to 25,000 events/s and sort purity of Above 95% (typical). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Cell Sorter is used in GFP-positive cell enrichment, immune cell subset isolation, clonal cell line development, teaching and small-lab sorting and sorting inside biosafety cabinets. Across the wider Cell Sorters class, laboratories also deploy it for stem cell and progenitor enrichment, single-cell cloning of engineered cell lines and sorting for single-cell RNA sequencing.
Which standards and certifications apply?
Relevant standards and methods include ISAC Cell Sorter Biosafety Standards, IEC 61010-1, IEC 60825-1, EN 12469, ISO 14698-1, CLSI H62 and ISAC FCS 3.1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sorters need a clean, temperature-stable room, compressed air or nitrogen supply and often a dedicated operator. Perform daily setup with calibration beads to set drop delay, verify stream stability and check sort accuracy. Decontaminate fluidics with bleach or dedicated cleaning solutions before and after every sample and sterilize sheath paths for primary cell work. Sorting human or infectious material requires a biosafety assessment, with containment verified by an aerosol test such as potassium iodide or fluorescent bead methods. Nozzles, O-rings and sheath filters are consumables and should be replaced on a schedule. Laboratories should log sorts, purity checks and preventive maintenance to support reproducibility and audits.
How do I select the right Benchtop Cell Sorter?
Choose a benchtop sorter for in-house routine sorting with up to about 10 colors and two to four populations, especially when core access is limited or biosafety cabinet placement is needed. For large panels or high rates choose a high-speed system. In an RFQ specify lasers, sort ways, nozzle, aerosol management and plate formats.
How does it compare with other Cell Sorters variants?
Choose a sorter on purity, yield, viability and containment requirements. Determine how many populations you need to collect at once, since two-way, four-way and six-way sorting require different deflection hardware. Match nozzle size, from 70 to 130 micrometers, to cell size and fragility; larger nozzles and lower pressure are gentler for primary cells. Check sort speed, typically 20,000 to 70,000 events per second, against the abort rate and recovery. For infectious, human primary or viral vector samples, specify an aerosol-managed or enclosed system and a class II biosafety cabinet. Consider single-cell deposition into 96 or 384-well plates, index sorting, number of lasers, and ease of use. Also confirm sterile fluidics cleaning and availability of service engineers.
Full specifications
| Laser configuration | 2–4 (405/488/561/640 nm) |
|---|---|
| Fluorescence channels | 6–14 |
| Sort streams | 2 or 4-way |
| Nozzle size | 70–100 µm |
| Maximum sort rate | Up to 25,000 events/s |
| Sort purity | Above 95% (typical) |
| Sheath pressure | 10–30 psi |
| Plate deposition formats | 24–384 well plates |
| Footprint | Approx. 100 × 70 × 70 cm |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- GFP-positive cell enrichment
- Immune cell subset isolation
- Clonal cell line development
- Teaching and small-lab sorting
- Sorting inside biosafety cabinets
Key features
- Compact footprint suitable for placement inside or beside a biosafety cabinet
- Two to four lasers with six to 14 fluorescence channels
- Automated alignment and drop delay setup shortens daily start time
- Two-way or four-way sorting into tubes or multiwell plates
- Integrated aerosol management option for sorting human or infectious samples
- Pre-configured sort templates for routine enrichment and single-cell cloning
Frequently asked questions about Benchtop Cell Sorter
Benchtop sorters are smaller, use fewer lasers and detectors, and sort at lower top speeds, typically up to 25,000 events per second. They cost less to operate and need less training, but offer fewer colors and less configurability than core-facility systems.
Many compact models are designed to fit inside a class II biosafety cabinet or provide integrated aerosol evacuation. Cabinet airflow must be validated for the specific sorter, and aerosol containment should be tested before sorting human or infectious material.
Prepare a single-cell suspension filtered through a 35 to 70 micrometer strainer at 5 to 20 million cells per milliliter, in buffer with protein and EDTA to limit clumping. Include a viability dye and collect into medium containing serum or albumin.
It analyzes each cell by scatter and fluorescence, then a vibrating nozzle breaks the stream into droplets. Droplets containing cells that meet the sort gate are electrically charged and deflected by high-voltage plates into collection tubes or plates, leaving unwanted cells in waste.
Purity above 95 percent is common for well-separated populations sorted in purity mode, while yield and recovery are lower at high event rates. Actual results depend on gating, sample quality, sort mode, nozzle size and the abundance of target cells.
Sorting applies shear, pressure and electrostatic stress, so some loss of viability is possible. Using larger nozzles, lower sheath pressure, cooled collection, protein-supplemented collection media and lower event rates can preserve viability and downstream function for fragile primary cells.