High-Parameter Research Flow Cytometer
高参数科研流式细胞仪
- SKU FCY-0002
- Flow Cytometers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Laser configuration | 4–7 (355/405/488/561/640 nm) |
|---|---|
| Fluorescence detectors | 18–30+ |
| Dynamic range | Approx. 7 logs |
| Maximum event rate | Up to 70,000 events/s |
| Fluorescence sensitivity | FITC below 50 MESF, PE below 20 MESF (typical) |
| Small-particle detection | Approx. 100–200 nm (optional) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-1
What is the High-Parameter Research Flow Cytometer?
A high-parameter research flow cytometer is a modular analyzer with four to seven lasers and 18 to 30 or more fluorescence detectors. It is chosen for deep immunophenotyping, rare-event analysis and complex panels where sensitivity and flexible optical configuration matter more than footprint.
What is the High-Parameter Research Flow Cytometer?
A high-parameter research flow cytometer is a modular analyzer with four to seven lasers and 18 to 30 or more fluorescence detectors. It is chosen for deep immunophenotyping, rare-event analysis and complex panels where sensitivity and flexible optical configuration matter more than footprint.
Overview
High-parameter research analyzers use a modular optical bench in which lasers, filter blocks and detectors are configurable. Typical systems combine 355, 405, 488, 561 and 640 nm lasers with 18 to 30 or more detectors in octagon or trigon arrays, allowing panels of 20 or more colors. Laser-spatial separation and time delay reduce crosstalk, and low-noise electronics with high dynamic range, often 7 logs, resolve dim and bright populations together. Event rates reach 20,000 to 70,000 events per second, and optional high-throughput loaders, small-particle side-scatter detection and plate readers extend applications. Software supports high-dimensional analysis workflows with compensation libraries, tSNE and UMAP export. The instruments require more operator training and a dedicated environment with precise temperature control.
How does it work?
A flow cytometer uses sheath fluid to hydrodynamically focus a sample into a narrow core stream so cells cross the laser interrogation point one at a time. Scattered light is collected at small angles (forward scatter, related to size) and at 90 degrees (side scatter, related to granularity). Fluorochromes are excited by lasers, commonly 405, 488, 561 and 640 nm, and emission is split by dichroic filters and bandpass filters to photomultiplier tubes or photodiodes. Conventional instruments assign one detector per fluorochrome and apply a compensation matrix, whereas spectral instruments capture the full emission spectrum and unmix it mathematically. Electronics digitize pulse height, area and width, and software records list-mode FCS files for gating and statistical analysis.
What are the key features?
- Four to seven lasers from UV to red with spatially separated beam spots
- 18 to 30 or more fluorescence detectors in low-crosstalk octagon or trigon arrays
- Dynamic range of about 7 logs for simultaneous dim and bright populations
- Modular filter blocks allow panel-specific optical reconfiguration by the user
- Optional small-particle detection channel for extracellular vesicles and bacteria
- Software export for tSNE, UMAP and high-dimensional clustering workflows
What are the technical specifications?
A typical high-parameter research flow cytometer configuration offers laser configuration of 4–7 (355/405/488/561/640 nm), fluorescence detectors of 18–30+, dynamic range of Approx. 7 logs, maximum event rate of Up to 70,000 events/s, fluorescence sensitivity of FITC below 50 MESF, PE below 20 MESF (typical) and small-particle detection of Approx. 100–200 nm (optional). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Parameter Research Flow Cytometer is used in deep immunophenotyping (20+ markers), rare-event and minimal residual disease research, single-cell signaling and phospho-flow, extracellular vesicle analysis and immuno-oncology biomarker discovery. Across the wider Flow Cytometers class, laboratories also deploy it for immunophenotyping of lymphocyte subsets, CD34 stem cell enumeration and cell cycle and apoptosis analysis.
Which standards and certifications apply?
Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-1, IEC 61010-1, IEC 61010-2-101, IEC 60825-1 and ISAC FCS 3.1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the cytometer on a vibration-free bench with stable power and ambient temperature between 15 and 30 degrees Celsius, and provide waste handling for potentially biohazardous effluent, typically with bleach treatment. Run daily quality control using fluorescent beads to verify laser alignment, sensitivity and coefficient of variation, and keep Levey-Jennings style records of detector voltages. Perform daily and weekly fluidics cleaning to avoid clogging, and replace sheath filters and tubing on schedule. Laser power and optical alignment should be checked by trained service staff at least annually. Laboratories working under ISO 15189 or GLP should enable audit trails, electronic signatures and validated software updates.
How do I select the right High-Parameter Research Flow Cytometer?
Select a high-parameter analyzer when your validated panels exceed about 12 colors or you need sensitivity for rare events. It costs more and needs skilled operators, so it suits core facilities and research groups. In an RFQ specify laser wavelengths and powers, detector count, dynamic range, sensitivity targets in MESF and loader compatibility.
How does it compare with other Flow Cytometers variants?
Select a cytometer by panel complexity, sensitivity and workflow. Define the maximum number of simultaneous colors, then choose laser and detector count to match; conventional filter-based systems are simple for 4 to 12 colors, while spectral systems ease panel design beyond 20. Check resolution of dim populations, small particle detection and event rate, typically 10,000 to 100,000 events per second. Consider footprint, whether a compact personal analyzer or a full research platform is required, and whether an acoustic focusing or plate loader is needed for throughput. Verify that software provides compensation or unmixing, batch analysis and user access control. For clinical use, confirm that the supplier can support IVD documentation, calibration beads and a validated quality control routine.
Full specifications
| Laser configuration | 4–7 (355/405/488/561/640 nm) |
|---|---|
| Fluorescence detectors | 18–30+ |
| Dynamic range | Approx. 7 logs |
| Maximum event rate | Up to 70,000 events/s |
| Fluorescence sensitivity | FITC below 50 MESF, PE below 20 MESF (typical) |
| Small-particle detection | Approx. 100–200 nm (optional) |
| Sample flow rate | 10–240 µL/min |
| Carry-over | Below 0.5% |
| Data format | FCS 3.1 (and FCS 3.2) |
| Operating temperature | 18–26 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Deep immunophenotyping (20+ markers)
- Rare-event and minimal residual disease research
- Single-cell signaling and phospho-flow
- Extracellular vesicle analysis
- Immuno-oncology biomarker discovery
Key features
- Four to seven lasers from UV to red with spatially separated beam spots
- 18 to 30 or more fluorescence detectors in low-crosstalk octagon or trigon arrays
- Dynamic range of about 7 logs for simultaneous dim and bright populations
- Modular filter blocks allow panel-specific optical reconfiguration by the user
- Optional small-particle detection channel for extracellular vesicles and bacteria
- Software export for tSNE, UMAP and high-dimensional clustering workflows
Frequently asked questions about High-Parameter Research Flow Cytometer
Systems with five lasers and 30 or more detectors commonly run validated panels of 20 to 28 colors, and some research groups report 40 or more with spectral designs. Practical limits are set by fluorochrome availability, spreading error and panel optimization effort.
A wide dynamic range, around 7 logs, lets dim populations and very bright populations sit within the same scale without clipping. It improves resolution of rare dim subsets and reduces the need to re-acquire samples at different voltages.
It needs a stable bench or dedicated room with temperature held within about 18 to 26 degrees Celsius, low vibration and clean power, often with a UPS. Some lasers require water or forced air cooling, and a dedicated waste and sheath supply is recommended.
A flow cytometer measures forward scatter, side scatter and fluorescence intensity from each cell or particle. These signals report relative size, internal complexity and the presence or amount of fluorescently labeled markers, enabling counting, phenotyping and functional analysis at rates of thousands of cells per second.
Conventional cytometers use optical filters to direct a defined wavelength band to each detector and then compensate for overlap. Spectral cytometers record the whole emission spectrum across many detectors and unmix it, which allows more colors per panel and use of autofluorescence extraction.
Run quality control with fluorescent calibration beads every day of use to confirm laser alignment, sensitivity and stability. Full preventive maintenance by a trained engineer, including laser power and optical alignment verification, is normally performed once or twice a year.