Nanoplate-Based Digital PCR System
纳米板式数字 PCR 系统
- SKU DPC-0002
- Digital PCR
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Partition type | fixed nanoliter wells |
|---|---|
| Partitions per sample | 8,500–26,000 |
| Partition volume | 0.5–0.9 nL |
| Reaction volume | 10–40 µL |
| Detection channels | 2 to 5 |
| Dynamic range | about 5 logs |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 22174, CLSI MM19
What is the Nanoplate-Based Digital PCR System?
A nanoplate digital PCR system loads each sample into thousands of fixed nanoliter wells on a single-use plate, then cycles and images the plate in an integrated instrument. It is the right choice for laboratories that want a closed, automated workflow with low hands-on time and reduced contamination risk.
What is the Nanoplate-Based Digital PCR System?
A nanoplate digital PCR system loads each sample into thousands of fixed nanoliter wells on a single-use plate, then cycles and images the plate in an integrated instrument. It is the right choice for laboratories that want a closed, automated workflow with low hands-on time and reduced contamination risk.
Overview
In a nanoplate system the partitions are micro-machined wells, typically 8,500 to 26,000 per sample, sealed under oil or by a film to keep each reaction isolated. Loading is done in a single pipetting step, and the integrated instrument thermally cycles the plate and images all wells with a camera at multiple wavelengths. The fixed well geometry gives highly uniform partition volumes of about 0.5–0.9 nL and avoids droplet coalescence. Plates hold 8, 24 or 96 samples, and run time from loading to result is around 2–4 hours. Two to five color channels are available. The limitation is fixed partition number per plate format and higher consumable cost per sample, but workflow is simple and traceable, suitable for routine work.
How does it work?
In digital PCR the sample and master mix are partitioned into many independent reactions, as water-in-oil droplets, nanoliter wells on a plate, or microchambers on a chip. Partitions are thermally cycled to end point, and a fluorescence reader classifies each as positive or negative. If λ is the average number of copies per partition, the fraction of negative partitions equals e^−λ, so concentration follows from the count of negatives, partition volume and dilution. Because quantification relies on counting rather than amplification kinetics, it is less affected by inhibitors and efficiency differences and offers high precision at low copy number. Key components are the partitioning unit, a thermal cycler, a multi-color optical reader and analysis software with threshold setting.
What are the key features?
- Single-step loading into fixed nanoliter wells
- Integrated cycling and imaging in one instrument
- Uniform partition volumes without droplet coalescence
- Plates for 8, 24 or 96 samples
- Two to five color channels for multiplexing
- Audit trail and user management options
What are the technical specifications?
A typical nanoplate-based digital pcr system configuration offers partition type of fixed nanoliter wells, partitions per sample of 8,500–26,000, partition volume of 0.5–0.9 nL, reaction volume of 10–40 µL, detection channels of 2 to 5 and dynamic range of about 5 logs. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Nanoplate-Based Digital PCR System is used in clinical research assays, residual disease monitoring, cell and gene therapy vector titer and environmental DNA quantification. Across the wider Digital PCR class, laboratories also deploy it for rare mutation and liquid biopsy detection, absolute quantification of viral load and copy-number variation analysis.
Which standards and certifications apply?
Relevant standards and methods include ISO 20395, ISO 22174, CLSI MM19, dMIQE guidelines (research reporting), IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the system on a stable bench, and keep sample preparation, partitioning and post-amplification steps in separate areas to limit amplicon contamination. Use the consumables and oil specified by the supplier, and avoid bubbles during droplet or plate loading. Include no-template and positive controls in every run and set fluorescence thresholds consistently. Verify partition volume and optical performance at installation and periodically with reference materials. Droplet generators and readers need routine cleaning and cartridge inspection. Plan for software validation, data retention and audit trail if results are used for clinical or regulated decisions, and establish the acceptable range of partitions per sample.
How do I select the right Nanoplate-Based Digital PCR System?
Select a nanoplate system when workflow simplicity, traceability and low contamination risk outweigh consumable cost. It suits routine use more than droplet formats but offers fewer partitions in some plate types. In an RFQ, specify plate formats, partitions per sample, channel count, samples per run, time to result, software validation and data-integrity features, and consumable lead time.
How does it compare with other Digital PCR variants?
The decisive parameters are partition number and volume, which set dynamic range and precision, and the number of fluorescence colors, which set multiplexing. Droplet systems offer high partition counts at relatively low consumable cost, nanoplate and chip formats offer simpler, more automated workflows and lower contamination risk. Consider sample throughput, hands-on time, and whether partitioning, cycling and reading are integrated or separate instruments. Check software for rare-event calling, copy-number variation and Poisson confidence intervals. For clinical or reference-material work, ask about lot traceability of consumables and validation guidance such as the dMIQE recommendations. Account for consumable cost per sample, which often exceeds qPCR.
Full specifications
| Partition type | fixed nanoliter wells |
|---|---|
| Partitions per sample | 8,500–26,000 |
| Partition volume | 0.5–0.9 nL |
| Reaction volume | 10–40 µL |
| Detection channels | 2 to 5 |
| Dynamic range | about 5 logs |
| Plate capacity | 8, 24 or 96 samples |
| Hands-on time | about 15 min per plate |
| Time to result | 2–4 h |
| Power supply | 100–240 V AC, 50/60 Hz, about 500 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Clinical research assays
- Residual disease monitoring
- Cell and gene therapy vector titer
- Environmental DNA quantification
Key features
- Single-step loading into fixed nanoliter wells
- Integrated cycling and imaging in one instrument
- Uniform partition volumes without droplet coalescence
- Plates for 8, 24 or 96 samples
- Two to five color channels for multiplexing
- Audit trail and user management options
Frequently asked questions about Nanoplate-Based Digital PCR System
Some plates use a sealing oil or film over the wells to prevent cross-talk and evaporation. Plate design differs by supplier, so follow the specified loading and sealing procedure exactly.
Plate formats commonly hold 8, 24 or 96 samples. Choose the format that matches your batch size, since partially filled plates still consume a full consumable.
Yes. Plate loading can be done with an automated liquid handler, and the instrument can be integrated with a robot arm on selected models. Confirm plate handling and software interfaces before purchase.
Digital PCR divides a sample into thousands of tiny partitions, amplifies each to end point, and counts positive and negative partitions. Poisson statistics then give absolute copy number per microliter without a calibration curve, with high precision at low target levels.
Real-time PCR infers quantity from the cycle at which fluorescence crosses a threshold and needs a standard curve. Digital PCR counts positive partitions at end point, giving absolute quantity, better tolerance of inhibitors and better precision for small fold differences.
More partitions extend dynamic range and improve precision at low copy number. Systems range from about 10,000 to over 20,000 partitions per sample in droplet formats, and from a few thousand to tens of thousands in plate or chip formats.