Dual-Block Gradient Thermal Cycler

双模块梯度热循环仪

  • SKU GRP-0003
  • Gradient PCR
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Block format2 × 48 or 2 × 96 wells
Gradient span1–24 °C per block
Temperature range4–99 °C
Max ramp rate2.5–3.5 °C/s
Block uniformity±0.3 °C
Gradient accuracy±0.3 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, ISO 20395

What is the Dual-Block Gradient Thermal Cycler?

A dual-block gradient thermal cycler has two independently controlled blocks, each with its own gradient capability, so two optimisation experiments or an optimisation plus a routine run can happen at once. It is the right choice for busy laboratories that want gradient and parallel operation together.

What is the Dual-Block Gradient Thermal Cycler?

A dual-block gradient thermal cycler has two independently controlled blocks, each with its own gradient capability, so two optimisation experiments or an optimisation plus a routine run can happen at once. It is the right choice for busy laboratories that want gradient and parallel operation together.

Overview

The dual-block gradient cycler combines two 48-well or 96-well Peltier blocks, each with its own heated lid and controller, and each supports a linear gradient on the annealing step. One block can carry out a primer optimisation while the second runs a validated protocol, or both can run gradients with different spans. Gradient span is commonly 1–24 °C per block. Block uniformity is ±0.3 °C and ramp rate is 2.5–3.5 °C/s. Power draw of 800–1000 W requires adequate bench circuit capacity. Calibration must be performed on each block separately, including gradient verification. Programs and gradients are stored in a shared library, and run status for both blocks appears on one display.

How does it work?

A gradient cycler uses a Peltier block with independently controlled heating and cooling at each end, or multiple thermal zones, to establish a linear temperature profile across the block. A typical range is 1–30 °C, so a 96-well block with 12 columns can test 12 different annealing temperatures in one run, for example 50–65 °C. Temperature sensors along the block feed back to a controller, and the software calculates the actual temperature of every column. Alternative designs use three to six independently controlled zones, which give a defined temperature in each zone rather than a continuous gradient, and improve accuracy of the set points. After the run, amplicons are compared by gel electrophoresis or melt curve to identify the annealing temperature with the highest specific yield.

What are the key features?

  • Two independent blocks, each with gradient capability
  • Independent heated lids and controllers
  • Parallel optimisation and routine runs
  • Shared protocol library with per-block status display
  • Gradient span up to 24 °C per block
  • Blocks can be linked for one large run without gradient

What are the technical specifications?

A typical dual-block gradient thermal cycler configuration offers block format of 2 × 48 or 2 × 96 wells, gradient span of 1–24 °C per block, temperature range of 4–99 °C, max ramp rate of 2.5–3.5 °C/s, block uniformity of ±0.3 °C and gradient accuracy of ±0.3 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dual-Block Gradient Thermal Cycler is used in shared core optimisation work, parallel method development, simultaneous optimisation and routine PCR and training courses. Across the wider Gradient PCR class, laboratories also deploy it for primer annealing temperature optimisation, polymerase and buffer comparison and multiplex PCR development.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, ISO 20395, ISO 22174 and CLSI MM19. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Gradient performance should be verified at installation with a multi-point probe at several set gradients, since accuracy at the ends of the block can differ from the center. Keep the block clean and ensure all tubes and plates are fully seated to maintain thermal contact. Use the same plate type for optimisation and routine runs, as wall thickness affects actual well temperature. Record the optimal annealing temperature and the column where it occurred. After optimisation, transfer the protocol to the routine cycler and verify that performance matches, because different blocks may differ slightly. Maintain pre-PCR and post-PCR separation and run no-template controls for every temperature tested.

How do I select the right Dual-Block Gradient Thermal Cycler?

Select a dual-block gradient cycler when multiple users need gradient capability without queueing. It costs more and uses more power than a single-block gradient unit. In an RFQ, specify format per block, gradient span per block, independent calibration certificates, power requirements and whether blocks can be linked for a single larger run.

How does it compare with other Gradient PCR variants?

Choose between true linear gradient and multi-zone designs. Linear gradients suit simple primer optimisation with 8 or 12 temperatures, while independent zones give more precise set points and let you run different protocols in different zones. Check the gradient span, maximum temperature difference, number of gradient steps, and whether gradient is available on every cycle step, including denaturation and extension. Consider block format, ramp rate and whether a real-time optical module is needed so melt curves can confirm specificity. Also look at software that displays calculated column temperatures and lets you save gradient conditions with protocols. For shared laboratories, dual-block gradient units add capacity. Verify gradient accuracy with a calibrated multi-point probe.

Full specifications

Full specifications
Block format2 × 48 or 2 × 96 wells
Gradient span1–24 °C per block
Temperature range4–99 °C
Max ramp rate2.5–3.5 °C/s
Block uniformity±0.3 °C
Gradient accuracy±0.3 °C
Independent blocks2
Reaction volume5–100 µL
Heated lid range30–110 °C
Power supply100–240 V AC, 50/60 Hz, about 1000 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Shared core optimisation work
  • Parallel method development
  • Simultaneous optimisation and routine PCR
  • Training courses

Key features

  • Two independent blocks, each with gradient capability
  • Independent heated lids and controllers
  • Parallel optimisation and routine runs
  • Shared protocol library with per-block status display
  • Gradient span up to 24 °C per block
  • Blocks can be linked for one large run without gradient

Frequently asked questions about Dual-Block Gradient Thermal Cycler

Yes, each block has independent controls, so both can run their own gradient with different centers and spans. Protocol start and end times are independent as well.

Related models

All Gradient PCR

Request a quotation for the Dual-Block Gradient Thermal Cycler

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote