Skip to main content
Lab Manufacturers China
Multi-Zone Independent-Temperature Thermal Cycler — product photo

Multi-Zone Independent-Temperature Thermal Cycler

多温区独立控温热循环仪

  • SKU GRP-0002
  • Gradient PCR
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Block format96 × 0.2 mL wells in 6 zones
Number of zones3 to 6
Zone temperature spanup to 24 °C
Zone accuracy±0.25 °C
Max ramp rate3–4 °C/s
Temperature range4–99 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, ISO 20395

What is the Multi-Zone Independent-Temperature Thermal Cycler?

A multi-zone thermal cycler divides the block into three to six independently heated zones, each set to a specific annealing temperature. It is the right choice when precise, discrete set points are needed, for example to optimise several primer pairs with different melting temperatures simultaneously.

What is the Multi-Zone Independent-Temperature Thermal Cycler?

A multi-zone thermal cycler divides the block into three to six independently heated zones, each set to a specific annealing temperature. It is the right choice when precise, discrete set points are needed, for example to optimise several primer pairs with different melting temperatures simultaneously.

Overview

In a multi-zone cycler, the block is divided into separate Peltier-controlled sections, typically six columns-pairs of 16 wells each, so each zone holds a defined temperature during annealing instead of a continuous linear gradient. Set points can be arbitrary within a span of up to 24 °C, so temperatures such as 52, 54, 58, 62 and 65 °C can be tested together. Each zone is calibrated independently, which gives better accuracy than a linear gradient, often ±0.25 °C. Zone separation lets the operator place different primer sets in different zones and run them in one program. Ramp rate is 3–4 °C/s. Because each zone has its own thermal hardware, cost and complexity are higher than linear gradient units.

How does it work?

A gradient cycler uses a Peltier block with independently controlled heating and cooling at each end, or multiple thermal zones, to establish a linear temperature profile across the block. A typical range is 1–30 °C, so a 96-well block with 12 columns can test 12 different annealing temperatures in one run, for example 50–65 °C. Temperature sensors along the block feed back to a controller, and the software calculates the actual temperature of every column. Alternative designs use three to six independently controlled zones, which give a defined temperature in each zone rather than a continuous gradient, and improve accuracy of the set points. After the run, amplicons are compared by gel electrophoresis or melt curve to identify the annealing temperature with the highest specific yield.

What are the key features?

  • Three to six independently controlled thermal zones
  • Discrete set points instead of a continuous gradient
  • Temperature span of up to 24 °C across zones
  • Independent calibration of each zone
  • Zone temperatures displayed as set and measured values
  • Works as a uniform block when zones share a set point

What are the technical specifications?

A typical multi-zone independent-temperature thermal cycler configuration offers block format of 96 × 0.2 mL wells in 6 zones, number of zones of 3 to 6, zone temperature span of up to 24 °C, zone accuracy of ±0.25 °C, max ramp rate of 3–4 °C/s and temperature range of 4–99 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Multi-Zone Independent-Temperature Thermal Cycler is used in multi-primer annealing optimisation, multiplex assay development, comparison of polymerases at set temperatures and high-GC amplicon optimisation. Across the wider Gradient PCR class, laboratories also deploy it for primer annealing temperature optimisation, polymerase and buffer comparison and multiplex PCR development.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, ISO 20395, ISO 22174 and CLSI MM19. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Gradient performance should be verified at installation with a multi-point probe at several set gradients, since accuracy at the ends of the block can differ from the center. Keep the block clean and ensure all tubes and plates are fully seated to maintain thermal contact. Use the same plate type for optimisation and routine runs, as wall thickness affects actual well temperature. Record the optimal annealing temperature and the column where it occurred. After optimisation, transfer the protocol to the routine cycler and verify that performance matches, because different blocks may differ slightly. Maintain pre-PCR and post-PCR separation and run no-template controls for every temperature tested.

How do I select the right Multi-Zone Independent-Temperature Thermal Cycler?

Select a multi-zone cycler when primer sets have different melting temperatures or when exact set points must be tested. Compared with linear gradient models, it gives defined temperatures but fewer steps. In an RFQ, specify number of zones, maximum span, accuracy per zone, plate format and whether zones can run independent program steps or only independent annealing temperatures.

How does it compare with other Gradient PCR variants?

Choose between true linear gradient and multi-zone designs. Linear gradients suit simple primer optimisation with 8 or 12 temperatures, while independent zones give more precise set points and let you run different protocols in different zones. Check the gradient span, maximum temperature difference, number of gradient steps, and whether gradient is available on every cycle step, including denaturation and extension. Consider block format, ramp rate and whether a real-time optical module is needed so melt curves can confirm specificity. Also look at software that displays calculated column temperatures and lets you save gradient conditions with protocols. For shared laboratories, dual-block gradient units add capacity. Verify gradient accuracy with a calibrated multi-point probe.

Full specifications

Full specifications
Block format96 × 0.2 mL wells in 6 zones
Number of zones3 to 6
Zone temperature spanup to 24 °C
Zone accuracy±0.25 °C
Max ramp rate3–4 °C/s
Temperature range4–99 °C
Block uniformity within a zone±0.3 °C
Reaction volume5–100 µL
Heated lid range30–110 °C
Power supply100–240 V AC, 50/60 Hz, about 700 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Multi-primer annealing optimisation
  • Multiplex assay development
  • Comparison of polymerases at set temperatures
  • High-GC amplicon optimisation

Key features

  • Three to six independently controlled thermal zones
  • Discrete set points instead of a continuous gradient
  • Temperature span of up to 24 °C across zones
  • Independent calibration of each zone
  • Zone temperatures displayed as set and measured values
  • Works as a uniform block when zones share a set point

Frequently asked questions about Multi-Zone Independent-Temperature Thermal Cycler

A gradient block creates a continuous linear temperature change across columns. A multi-zone block holds separate set temperatures in discrete zones, with each zone calibrated independently. Multi-zone designs typically give better set-point accuracy but fewer steps.

Related models

All Gradient PCR

Request a quotation for the Multi-Zone Independent-Temperature Thermal Cycler

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote