FTIR Spectrometer for Seized Drug Identification — product photo

FTIR Spectrometer for Seized Drug Identification

缴获毒品鉴定用 FTIR 光谱仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Spectral range7800–350 cm-1
Resolution≤ 0.5 cm-1 (4 cm-1 typical use)
Signal-to-noise ratio≥ 30,000:1 (peak-to-peak, 1 min)
ATR crystalDiamond, single bounce
DetectorDLaTGS
Sample amount< 1 mg
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E2329, ISO/IEC 17025, ISO 21043

What is the FTIR Spectrometer for Seized Drug Identification?

An FTIR spectrometer with ATR accessory identifies seized drugs from their infrared fingerprint with little or no preparation. It provides a rapid, non-destructive screening and identification technique for bulk powders, tablets and cutting agents.

What is the FTIR Spectrometer for Seized Drug Identification?

An FTIR spectrometer with ATR accessory identifies seized drugs from their infrared fingerprint with little or no preparation. It provides a rapid, non-destructive screening and identification technique for bulk powders, tablets and cutting agents.

Overview

The FTIR system uses an interferometer to record an infrared spectrum over approximately 4000 to 400 cm-1. A diamond attenuated total reflectance accessory allows solids and powders to be pressed directly against the crystal, so analysis takes under a minute. The spectrum is compared with libraries of controlled substances, salts, excipients and cutting agents, and mixtures can be interpreted by spectral subtraction or multi-component search algorithms. FTIR distinguishes salt forms and polymorphs, which mass spectrometry cannot, and supports identification of unknown compounds through functional group analysis. Its limitation is sensitivity and mixture resolution, because a minor component below roughly 5 percent may not be identifiable. Resolution of 4 cm-1 is sufficient for most work, and the ATR crystal must be cleaned between samples.

How does it work?

Drug analysis relies on orthogonal techniques to reach a confident identification. Gas chromatography and liquid chromatography separate components, and mass spectrometry measures mass-to-charge ratio and fragmentation patterns that are matched to reference libraries. Fourier transform infrared spectroscopy measures molecular vibrations and produces a fingerprint spectrum of the bulk material, often with an attenuated total reflectance crystal that needs no sample preparation. Raman spectroscopy uses laser scattering and can analyze through glass or plastic packaging. Ion mobility spectrometry separates ionized molecules by drift time in an electric field, offering rapid trace detection. Quantitation requires calibration with certified reference materials and internal standards. Software compares spectra with libraries, reports match scores and stores results with chain-of-custody information.

What are the key features?

  • Diamond ATR for direct analysis of powders and tablets
  • Analysis time under one minute per sample
  • Libraries for controlled substances, salts and cutting agents
  • Mixture search and spectral subtraction tools
  • Distinguishes salt forms and polymorphs

What are the technical specifications?

A typical ftir spectrometer for seized drug identification configuration offers spectral range of 7800–350 cm-1, resolution of ≤ 0.5 cm-1 (4 cm-1 typical use), signal-to-noise ratio of ≥ 30,000:1 (peak-to-peak, 1 min), ATR crystal of Diamond, single bounce, detector of DLaTGS and sample amount of < 1 mg. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The FTIR Spectrometer for Seized Drug Identification is used in rapid seized drug screening, tablet and powder identification, salt form and polymorph analysis and customs laboratories. Across the wider Drug Analysis Systems class, laboratories also deploy it for seized drug identification, forensic laboratory casework and customs and border screening.

Which standards and certifications apply?

Relevant standards and methods include ASTM E2329, ISO/IEC 17025, ISO 21043, UNODC Recommended Methods for Drug Identification and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Use certified reference materials for calibration and identification, and run blanks to detect carryover, because potent drugs can contaminate subsequent samples. Establish system suitability and tuning checks for mass spectrometers and verify library matching against known standards. Safety is important, since samples may include highly potent opioids, so use fume hoods, appropriate personal protective equipment and waste handling procedures. Keep stable power, carrier gas purity and temperature control in the room. Maintain chain-of-custody and data security, and validate methods under ISO/IEC 17025 with measurement uncertainty where quantitation is reported. Schedule preventive maintenance for ion sources, liners, columns and optical components.

How do I select the right FTIR Spectrometer for Seized Drug Identification?

Select FTIR when rapid, non-destructive identification of bulk material is the priority and as a complement to GC-MS. It is less effective for trace or complex mixtures. In an RFQ, specify spectral range, resolution, ATR crystal type, library content and software reporting features.

How does it compare with other Drug Analysis Systems variants?

Select by sample type and the confidence level your laboratory must report. Seized drug laboratories typically pair a screening technique with a confirmatory one, for example FTIR or color test with GC-MS. LC-MS/MS suits thermally labile, polar or low-dose compounds, including new psychoactive substances and pharmaceuticals in complex matrices. Portable Raman or FTIR suits field identification by customs and police, while ion mobility suits trace detection on surfaces. Check the availability and size of spectral libraries, the ability to add custom entries and the quality of software reporting. Consider throughput and autosampler capacity, consumables cost, and the skill level of operators. Accredited laboratories should confirm that instrument performance checks, such as tuning for GC-MS, are supported and documented.

Full specifications

Full specifications
Spectral range7800–350 cm-1
Resolution≤ 0.5 cm-1 (4 cm-1 typical use)
Signal-to-noise ratio≥ 30,000:1 (peak-to-peak, 1 min)
ATR crystalDiamond, single bounce
DetectorDLaTGS
Sample amount< 1 mg
Analysis time< 60 s
LibraryForensic drug libraries, custom entries
SoftwareSearch, subtraction, reporting
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Rapid seized drug screening
  • Tablet and powder identification
  • Salt form and polymorph analysis
  • Customs laboratories

Key features

  • Diamond ATR for direct analysis of powders and tablets
  • Analysis time under one minute per sample
  • Libraries for controlled substances, salts and cutting agents
  • Mixture search and spectral subtraction tools
  • Distinguishes salt forms and polymorphs

Frequently asked questions about FTIR Spectrometer for Seized Drug Identification

It can identify major components of simple mixtures using library search and spectral subtraction, but minor components below about 5 percent may be missed, so GC-MS is often used for confirmation.

Request a quotation for the FTIR Spectrometer for Seized Drug Identification

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.