Skip to main content
Lab Manufacturers China
LC-MS/MS System for Drugs of Abuse Confirmation — product photo

LC-MS/MS System for Drugs of Abuse Confirmation

滥用药物确证用 LC-MS/MS 系统

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Mass analyzerTriple quadrupole
Mass range5–2000 m/z
MRM speed≥ 500 transitions/s
Polarity switching≤ 5 ms
UHPLC pressure limit≥ 600 bar
IonizationESI / APCI
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E2329, ISO/IEC 17025, ISO 21043

What is the LC-MS/MS System for Drugs of Abuse Confirmation?

An LC-MS/MS system for drugs of abuse confirmation separates compounds by liquid chromatography and quantifies them by multiple reaction monitoring. It is suited to polar, thermally labile and low-dose drugs and their metabolites.

What is the LC-MS/MS System for Drugs of Abuse Confirmation?

An LC-MS/MS system for drugs of abuse confirmation separates compounds by liquid chromatography and quantifies them by multiple reaction monitoring. It is suited to polar, thermally labile and low-dose drugs and their metabolites.

Overview

The system pairs a high-pressure liquid chromatograph, often a UHPLC operating to 600 bar or more, with a triple quadrupole mass spectrometer. Electrospray or atmospheric pressure chemical ionization forms ions, the first quadrupole selects a precursor ion, collision-induced dissociation fragments it, and the third quadrupole monitors characteristic product ions in multiple reaction monitoring mode. Two transitions per analyte with a defined ion ratio support identification criteria. Panels of 50 to 200 compounds can be analyzed in under 10 minutes using fast gradients. Stable isotope-labeled internal standards correct for matrix effects and recovery. The instrument reaches pg/mL sensitivity in complex matrices such as urine, blood and oral fluid. It is more costly than GC-MS and demands careful management of matrix effects, carryover and ion suppression.

How does it work?

Drug analysis relies on orthogonal techniques to reach a confident identification. Gas chromatography and liquid chromatography separate components, and mass spectrometry measures mass-to-charge ratio and fragmentation patterns that are matched to reference libraries. Fourier transform infrared spectroscopy measures molecular vibrations and produces a fingerprint spectrum of the bulk material, often with an attenuated total reflectance crystal that needs no sample preparation. Raman spectroscopy uses laser scattering and can analyze through glass or plastic packaging. Ion mobility spectrometry separates ionized molecules by drift time in an electric field, offering rapid trace detection. Quantitation requires calibration with certified reference materials and internal standards. Software compares spectra with libraries, reports match scores and stores results with chain-of-custody information.

What are the key features?

  • Triple quadrupole with MRM for selective quantitation
  • UHPLC front end for fast separation of large panels
  • Electrospray and APCI ionization options
  • Isotope-labeled internal standard support in the software
  • Polarity switching for mixed positive and negative panels

What are the technical specifications?

A typical lc-ms/ms system for drugs of abuse confirmation configuration offers mass analyzer of Triple quadrupole, mass range of 5–2000 m/z, MRM speed of ≥ 500 transitions/s, polarity switching of ≤ 5 ms, UHPLC pressure limit of ≥ 600 bar and ionization of ESI / APCI. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The LC-MS/MS System for Drugs of Abuse Confirmation is used in quantitative confirmation of drugs of abuse, new psychoactive substance panels, workplace and clinical toxicology confirmation and drug metabolite profiling. Across the wider Drug Analysis Systems class, laboratories also deploy it for seized drug identification, forensic laboratory casework and customs and border screening.

Which standards and certifications apply?

Relevant standards and methods include ASTM E2329, ISO/IEC 17025, ISO 21043, UNODC Recommended Methods for Drug Identification and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Use certified reference materials for calibration and identification, and run blanks to detect carryover, because potent drugs can contaminate subsequent samples. Establish system suitability and tuning checks for mass spectrometers and verify library matching against known standards. Safety is important, since samples may include highly potent opioids, so use fume hoods, appropriate personal protective equipment and waste handling procedures. Keep stable power, carrier gas purity and temperature control in the room. Maintain chain-of-custody and data security, and validate methods under ISO/IEC 17025 with measurement uncertainty where quantitation is reported. Schedule preventive maintenance for ion sources, liners, columns and optical components.

How do I select the right LC-MS/MS System for Drugs of Abuse Confirmation?

Select LC-MS/MS when compounds are polar, labile or present at low concentration, or when large panels need quantitation. GC-MS remains cheaper for volatile drugs. In an RFQ, specify panel size, required LOQ, ionization modes, autosampler capacity, software validation and service support.

How does it compare with other Drug Analysis Systems variants?

Select by sample type and the confidence level your laboratory must report. Seized drug laboratories typically pair a screening technique with a confirmatory one, for example FTIR or color test with GC-MS. LC-MS/MS suits thermally labile, polar or low-dose compounds, including new psychoactive substances and pharmaceuticals in complex matrices. Portable Raman or FTIR suits field identification by customs and police, while ion mobility suits trace detection on surfaces. Check the availability and size of spectral libraries, the ability to add custom entries and the quality of software reporting. Consider throughput and autosampler capacity, consumables cost, and the skill level of operators. Accredited laboratories should confirm that instrument performance checks, such as tuning for GC-MS, are supported and documented.

Full specifications

Full specifications
Mass analyzerTriple quadrupole
Mass range5–2000 m/z
MRM speed≥ 500 transitions/s
Polarity switching≤ 5 ms
UHPLC pressure limit≥ 600 bar
IonizationESI / APCI
Sensitivity (reserpine, 1 pg)S/N ≥ 1000:1 (RMS)
Autosampler capacity≥ 200 vials
Panel size50–200 compounds
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Quantitative confirmation of drugs of abuse
  • New psychoactive substance panels
  • Workplace and clinical toxicology confirmation
  • Drug metabolite profiling

Key features

  • Triple quadrupole with MRM for selective quantitation
  • UHPLC front end for fast separation of large panels
  • Electrospray and APCI ionization options
  • Isotope-labeled internal standard support in the software
  • Polarity switching for mixed positive and negative panels

Frequently asked questions about LC-MS/MS System for Drugs of Abuse Confirmation

It selectively detects compounds by precursor and product ions, reaches low detection limits in complex matrices and handles polar or labile compounds that GC-MS cannot analyze reliably.

Request a quotation for the LC-MS/MS System for Drugs of Abuse Confirmation

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote