Liquid Nitrogen Controlled-Rate Freezer
液氮程序降温仪
- SKU CRF-0003
- Cryogenic Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-1 (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 5–50 L |
|---|---|
| Cooling rate range | −0.1 to −10°C/min |
| Final temperature | Down to −180°C |
| Temperature accuracy | ±1°C |
| Sample capacity | 10–500 vials or bags per run |
| Program steps | Up to 50 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-011, ISO 20387
What is the Liquid Nitrogen Controlled-Rate Freezer?
A liquid nitrogen controlled-rate freezer cools samples along a programmed temperature curve, commonly −1°C per minute, by injecting liquid nitrogen into an insulated chamber. It is the right choice when cryopreservation protocols for cells, embryos or tissues require reproducible, validated freezing profiles.
What is the Liquid Nitrogen Controlled-Rate Freezer?
A liquid nitrogen controlled-rate freezer cools samples along a programmed temperature curve, commonly −1°C per minute, by injecting liquid nitrogen into an insulated chamber. It is the right choice when cryopreservation protocols for cells, embryos or tissues require reproducible, validated freezing profiles.
Overview
A controlled-rate freezer consists of an insulated chamber, a liquid nitrogen solenoid valve or cryogenic pump, a circulating fan, temperature probes and a programmable controller. The controller compares the chamber or sample probe temperature with the programmed profile and pulses nitrogen into the chamber, adjusting the flow to hold the set rate. Cooling rates from −0.1°C to −10°C per minute are typical, with a final temperature down to −180°C, and heating phases can be added to compensate latent heat of fusion during ice nucleation. Chamber volumes run from 5 to 50 L, holding vials, straws or bags in racks, with 10 to 500 samples per run. Profiles and run data are stored for batch records, and audit trail software is available. Liquid nitrogen supply at 1–2 bar and exhaust ventilation are needed.
How does it work?
Mechanical cryogenic freezers reach −150°C through multi-stage refrigeration. A cascade system links two or three compressor circuits, each with a different refrigerant, so that the evaporator of one stage cools the condenser of the next. Mixed-refrigerant systems use a single compressor with a blend of refrigerants that evaporates across a wide temperature range. Vacuum insulation panels and thick foam limit heat gain, and the chamber uses uniform air circulation or conduction shelves. Controlled-rate freezers follow a different principle, injecting liquid nitrogen or using a cold head to cool the chamber along a programmed ramp, commonly −1°C per minute, with a controller and sensors that follow temperature setpoints. Both types use PT100 sensors, alarms, and backup options such as liquid nitrogen injection or carbon dioxide.
What are the key features?
- Programmable profiles with multiple cooling, hold and heating steps.
- Cooling rates from −0.1°C to −10°C per minute with ±1°C accuracy.
- Sample probe control tracks the actual sample temperature, not only the chamber.
- Racks for vials, straws and freezing bags in one chamber.
- Run records and audit trail support batch documentation.
- Latent heat compensation reduces the temperature spike at ice nucleation.
What are the technical specifications?
A typical liquid nitrogen controlled-rate freezer configuration offers chamber volume of 5–50 L, cooling rate range of −0.1 to −10°C/min, final temperature of Down to −180°C, temperature accuracy of ±1°C, sample capacity of 10–500 vials or bags per run and program steps of Up to 50. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Liquid Nitrogen Controlled-Rate Freezer is used in cell therapy product freezing, embryo and gamete cryopreservation, hematopoietic stem cell freezing and cell line banking. Across the wider Cryogenic Freezers class, laboratories also deploy it for biobank sample storage without liquid nitrogen, cell line and primary cell storage and controlled-rate freezing of cell therapy products.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-011, ISO 20387, ISO 21009-1, EN 61326-1 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing, ISO 13485 manufacturing and IEC 61010-1; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Mechanical cryogenic freezers release substantial heat, often 1–3 kW, so allow at least 20–30 cm of clearance and adequate room cooling. Use a dedicated circuit with a stable supply and consider a UPS or a backup generator, as well as a liquid nitrogen or carbon dioxide backup injection system. Keep the ambient temperature below about 32°C. Limit door opening time and avoid loading warm samples in bulk. Clean the condenser filter every one to three months. Calibrate temperature sensors at least annually, test the alarms and log temperature continuously. Controlled-rate freezers need a clean liquid nitrogen supply, exhaust ventilation and oxygen monitoring. Plan service access and preventive maintenance contracts.
How do I select the right Liquid Nitrogen Controlled-Rate Freezer?
Select a liquid nitrogen controlled-rate freezer when freezing profile reproducibility matters and liquid nitrogen is available. For sites without nitrogen or only occasional use, passive freezing containers may suffice. In an RFQ, specify chamber volume, container types, rate range, probe count, nitrogen supply and audit trail requirements.
How does it compare with other Cryogenic Freezers variants?
Decide first between storage and freezing. For storage, compare mechanical freezers at −135°C to −150°C and liquid nitrogen vessels, weighing the benefit of no nitrogen supply against dependence on electricity. Check that the stated temperature is achieved at full load and at your room temperature, not only when empty. Size capacity in boxes or vials and examine the shelf or rack format. Compare power consumption, heat rejection to the room, noise, recovery time after door opening and alarm and backup options. For controlled freezing, confirm rate range, number of programmable steps, sample holding format and whether liquid nitrogen supply is acceptable. For regulated work, add data logging, password control and calibration support.
Full specifications
| Chamber volume | 5–50 L |
|---|---|
| Cooling rate range | −0.1 to −10°C/min |
| Final temperature | Down to −180°C |
| Temperature accuracy | ±1°C |
| Sample capacity | 10–500 vials or bags per run |
| Program steps | Up to 50 |
| Probes | Chamber and 1–3 sample probes |
| LN2 consumption | 2–10 L per run |
| LN2 supply pressure | 1–2 bar |
| Data output | USB, Ethernet, printer |
| Power supply | 220 V AC, 50/60 Hz, 0.3–1 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell therapy product freezing
- Embryo and gamete cryopreservation
- Hematopoietic stem cell freezing
- Cell line banking
Key features
- Programmable profiles with multiple cooling, hold and heating steps.
- Cooling rates from −0.1°C to −10°C per minute with ±1°C accuracy.
- Sample probe control tracks the actual sample temperature, not only the chamber.
- Racks for vials, straws and freezing bags in one chamber.
- Run records and audit trail support batch documentation.
- Latent heat compensation reduces the temperature spike at ice nucleation.
Frequently asked questions about Liquid Nitrogen Controlled-Rate Freezer
Cooling at a controlled rate, typically −1°C per minute, limits intracellular ice and osmotic damage, improving post-thaw viability for sensitive cells. A plain −80°C freezer gives an uncontrolled rate that varies with load and position.
When ice forms in the sample, it releases heat and temporarily raises temperature. The controller detects this and applies extra cooling or a programmed step, so the profile stays close to target and cell damage from the spike is reduced.
For regulated cell therapy and clinical products, yes. Installation, operational and performance qualification should confirm rate accuracy, probe calibration and uniformity across the load. The supplier can provide protocols, but the user owns the validation.
An ultra-low freezer operates at −80°C to −86°C, while a cryogenic freezer operates at −130°C to −150°C or lower. The lower range matters because it is below the glass transition of water near −135°C, where molecular motion effectively stops.
It can for many collections, removing nitrogen deliveries and lowering asphyxiation risk, but temperature is typically −135°C to −150°C rather than −196°C and the unit depends on power. Many sites keep duplicate samples in both formats.
Mechanical −150°C freezers typically draw 1.5–4 kWh per day per 100 L under normal use, and release several hundred watts to 2 kW of heat to the room. Always ask for measured energy consumption under defined load and ambient conditions.