Liquid Nitrogen Controlled-Rate Freezer — product photo

Liquid Nitrogen Controlled-Rate Freezer

液氮程序降温仪

  • SKU CRF-0003
  • Cryogenic Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • IEC 61010-1 (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume5–50 L
Cooling rate range−0.1 to −10°C/min
Final temperatureDown to −180°C
Temperature accuracy±1°C
Sample capacity10–500 vials or bags per run
Program stepsUp to 50
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-011, ISO 20387

What is the Liquid Nitrogen Controlled-Rate Freezer?

A liquid nitrogen controlled-rate freezer cools samples along a programmed temperature curve, commonly −1°C per minute, by injecting liquid nitrogen into an insulated chamber. It is the right choice when cryopreservation protocols for cells, embryos or tissues require reproducible, validated freezing profiles.

What is the Liquid Nitrogen Controlled-Rate Freezer?

A liquid nitrogen controlled-rate freezer cools samples along a programmed temperature curve, commonly −1°C per minute, by injecting liquid nitrogen into an insulated chamber. It is the right choice when cryopreservation protocols for cells, embryos or tissues require reproducible, validated freezing profiles.

Overview

A controlled-rate freezer consists of an insulated chamber, a liquid nitrogen solenoid valve or cryogenic pump, a circulating fan, temperature probes and a programmable controller. The controller compares the chamber or sample probe temperature with the programmed profile and pulses nitrogen into the chamber, adjusting the flow to hold the set rate. Cooling rates from −0.1°C to −10°C per minute are typical, with a final temperature down to −180°C, and heating phases can be added to compensate latent heat of fusion during ice nucleation. Chamber volumes run from 5 to 50 L, holding vials, straws or bags in racks, with 10 to 500 samples per run. Profiles and run data are stored for batch records, and audit trail software is available. Liquid nitrogen supply at 1–2 bar and exhaust ventilation are needed.

How does it work?

Mechanical cryogenic freezers reach −150°C through multi-stage refrigeration. A cascade system links two or three compressor circuits, each with a different refrigerant, so that the evaporator of one stage cools the condenser of the next. Mixed-refrigerant systems use a single compressor with a blend of refrigerants that evaporates across a wide temperature range. Vacuum insulation panels and thick foam limit heat gain, and the chamber uses uniform air circulation or conduction shelves. Controlled-rate freezers follow a different principle, injecting liquid nitrogen or using a cold head to cool the chamber along a programmed ramp, commonly −1°C per minute, with a controller and sensors that follow temperature setpoints. Both types use PT100 sensors, alarms, and backup options such as liquid nitrogen injection or carbon dioxide.

What are the key features?

  • Programmable profiles with multiple cooling, hold and heating steps.
  • Cooling rates from −0.1°C to −10°C per minute with ±1°C accuracy.
  • Sample probe control tracks the actual sample temperature, not only the chamber.
  • Racks for vials, straws and freezing bags in one chamber.
  • Run records and audit trail support batch documentation.
  • Latent heat compensation reduces the temperature spike at ice nucleation.

What are the technical specifications?

A typical liquid nitrogen controlled-rate freezer configuration offers chamber volume of 5–50 L, cooling rate range of −0.1 to −10°C/min, final temperature of Down to −180°C, temperature accuracy of ±1°C, sample capacity of 10–500 vials or bags per run and program steps of Up to 50. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Liquid Nitrogen Controlled-Rate Freezer is used in cell therapy product freezing, embryo and gamete cryopreservation, hematopoietic stem cell freezing and cell line banking. Across the wider Cryogenic Freezers class, laboratories also deploy it for biobank sample storage without liquid nitrogen, cell line and primary cell storage and controlled-rate freezing of cell therapy products.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-011, ISO 20387, ISO 21009-1, EN 61326-1 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing, ISO 13485 manufacturing and IEC 61010-1; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Mechanical cryogenic freezers release substantial heat, often 1–3 kW, so allow at least 20–30 cm of clearance and adequate room cooling. Use a dedicated circuit with a stable supply and consider a UPS or a backup generator, as well as a liquid nitrogen or carbon dioxide backup injection system. Keep the ambient temperature below about 32°C. Limit door opening time and avoid loading warm samples in bulk. Clean the condenser filter every one to three months. Calibrate temperature sensors at least annually, test the alarms and log temperature continuously. Controlled-rate freezers need a clean liquid nitrogen supply, exhaust ventilation and oxygen monitoring. Plan service access and preventive maintenance contracts.

How do I select the right Liquid Nitrogen Controlled-Rate Freezer?

Select a liquid nitrogen controlled-rate freezer when freezing profile reproducibility matters and liquid nitrogen is available. For sites without nitrogen or only occasional use, passive freezing containers may suffice. In an RFQ, specify chamber volume, container types, rate range, probe count, nitrogen supply and audit trail requirements.

How does it compare with other Cryogenic Freezers variants?

Decide first between storage and freezing. For storage, compare mechanical freezers at −135°C to −150°C and liquid nitrogen vessels, weighing the benefit of no nitrogen supply against dependence on electricity. Check that the stated temperature is achieved at full load and at your room temperature, not only when empty. Size capacity in boxes or vials and examine the shelf or rack format. Compare power consumption, heat rejection to the room, noise, recovery time after door opening and alarm and backup options. For controlled freezing, confirm rate range, number of programmable steps, sample holding format and whether liquid nitrogen supply is acceptable. For regulated work, add data logging, password control and calibration support.

Full specifications

Full specifications
Chamber volume5–50 L
Cooling rate range−0.1 to −10°C/min
Final temperatureDown to −180°C
Temperature accuracy±1°C
Sample capacity10–500 vials or bags per run
Program stepsUp to 50
ProbesChamber and 1–3 sample probes
LN2 consumption2–10 L per run
LN2 supply pressure1–2 bar
Data outputUSB, Ethernet, printer
Power supply220 V AC, 50/60 Hz, 0.3–1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cell therapy product freezing
  • Embryo and gamete cryopreservation
  • Hematopoietic stem cell freezing
  • Cell line banking

Key features

  • Programmable profiles with multiple cooling, hold and heating steps.
  • Cooling rates from −0.1°C to −10°C per minute with ±1°C accuracy.
  • Sample probe control tracks the actual sample temperature, not only the chamber.
  • Racks for vials, straws and freezing bags in one chamber.
  • Run records and audit trail support batch documentation.
  • Latent heat compensation reduces the temperature spike at ice nucleation.

Frequently asked questions about Liquid Nitrogen Controlled-Rate Freezer

Cooling at a controlled rate, typically −1°C per minute, limits intracellular ice and osmotic damage, improving post-thaw viability for sensitive cells. A plain −80°C freezer gives an uncontrolled rate that varies with load and position.

Request a quotation for the Liquid Nitrogen Controlled-Rate Freezer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.