Key specifications
| Detection principle | Laser or light-beam scanning with transmission detector |
|---|---|
| Light source | Semiconductor laser, 635–780 nm |
| Plate formats | 90 mm standard; 55 mm with adapter |
| Minimum detectable colony | 0.3 mm |
| Scan time | 3–15 s per plate |
| Counting range | 1–3,000 CFU per plate |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7218, ISO 4833-1, ISO 4833-2
What is the Laser Colony Counter?
A laser colony counter scans a plate with a moving beam and detects colonies as changes in transmitted light, giving an objective count independent of colony color. It suits laboratories working with similar-colored or translucent colonies.
What is the Laser Colony Counter?
A laser colony counter scans a plate with a moving beam and detects colonies as changes in transmitted light, giving an objective count independent of colony color. It suits laboratories working with similar-colored or translucent colonies.
Overview
A laser colony counter uses a scanning beam rather than a camera. A plate rotates or translates while a focused laser or collimated light beam passes through the agar, and a detector records the attenuation caused by each colony. Because measurement depends on light transmission rather than color contrast, the method distinguishes colonies that resemble the medium and works on translucent or pigmented organisms. Software converts the pattern of detected marks into a count, and peak height can be related to colony size so that merged colonies are separated or estimated. Some instruments combine laser scanning with imaging to give both a count and a visual record. Scanning takes seconds per plate, and results are objective and repeatable. Consistent agar depth matters because medium thickness affects the signal.
How does it work?
Automated colony counting replaces the naked-eye tally with a sensor and software. A plate is placed on a backlit or dark-field stage and a camera captures a high-resolution image. Software applies thresholding and brightness or color segmentation to separate colonies from the agar background, and size and circularity filters remove bubbles, dust and cracks. Counts are reported as colony-forming units and converted to CFU per millilitre or gram using the dilution. Laser counters scan with a moving beam and detect colonies by light attenuation, which avoids ambiguity from similar-colored growth, while fluorescence counters excite labeled or fluorogenic targets and read the emitted light. Many instruments estimate the number of merged colonies, flag plates outside the statistical counting range, and export images and results for review.
What are the key features?
- Scanning laser or collimated light beam with transmission detector
- Counts independent of colony color and contrast
- Peak analysis separates or estimates merged colonies
- Typical scan time of seconds per plate
- Optional combined camera image for visual verification
What are the technical specifications?
A typical laser colony counter configuration offers detection principle of Laser or light-beam scanning with transmission detector, light source of Semiconductor laser, 635–780 nm, plate formats of 90 mm standard; 55 mm with adapter, minimum detectable colony of 0.3 mm, scan time of 3–15 s per plate and counting range of 1–3,000 CFU per plate. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Laser Colony Counter is used in food and beverage microbiological testing, pharmaceutical microbiological testing, water analysis and research on translucent or pigmented organisms. Across the wider Colony Counters class, laboratories also deploy it for food and beverage microbiological testing, pharmaceutical environmental monitoring and water and wastewater analysis.
Which standards and certifications apply?
Relevant standards and methods include ISO 7218, ISO 4833-1, ISO 4833-2, ISO 11133, FDA BAM Chapter 3 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 60825-1 laser classification; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the counter on a stable bench away from direct sunlight, which changes illumination and thresholds. Keep the stage and optics clean, and follow the manufacturer interval for lamp or LED output checks. Verify performance with reference plates or a printed counting template and record results, because a drifting camera or dirty lens shifts counts. Before routine use, compare automated results with manual counts on typical media and organisms. For regulated laboratories, define who reviews flagged images, retain original images with the reported count, and place software updates under change control. Electrical safety follows IEC 61010-1.
How do I select the right Laser Colony Counter?
Choose a laser counter when colonies resemble the medium in color or when an objective optical measurement is preferred. In an RFQ confirm compatible plate sizes, laser wavelength and class, minimum detectable colony size, scan time, and whether a camera image is needed for review.
How does it compare with other Colony Counters variants?
Match the counter to your plate types and throughput before comparing prices. Low-volume work with standard 90 mm dishes is well served by an illuminated manual counter, while routine high volume justifies an automated system. Confirm the plate formats accepted, including 55 mm contact plates, 90 mm and 150 mm dishes, and any compact dry or film plates you use. Check the detection principle, because color-based imaging is fast while laser scanning better separates colonies of similar hue, and fluorescence is needed for chromogenic or fluorogenic media. Look for statistics that follow ISO 7218 and recognized compendial guidance, including counting-range limits and treatment of spreading growth. Consider image retention, LIMS export and validation against manual counts on your own plates.
Full specifications
| Detection principle | Laser or light-beam scanning with transmission detector |
|---|---|
| Light source | Semiconductor laser, 635–780 nm |
| Plate formats | 90 mm standard; 55 mm with adapter |
| Minimum detectable colony | 0.3 mm |
| Scan time | 3–15 s per plate |
| Counting range | 1–3,000 CFU per plate |
| Data output | CSV, optional image, LIMS export |
| Display | Integrated or external PC |
| Calibration | Reference plate with defined colony pattern |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Food and beverage microbiological testing
- Pharmaceutical microbiological testing
- Water analysis
- Research on translucent or pigmented organisms
Key features
- Scanning laser or collimated light beam with transmission detector
- Counts independent of colony color and contrast
- Peak analysis separates or estimates merged colonies
- Typical scan time of seconds per plate
- Optional combined camera image for visual verification
Frequently asked questions about Laser Colony Counter
An imaging counter measures reflected or transmitted light with a camera and relies on contrast between colonies and agar. A laser counter moves a focused beam across the plate and records attenuation point by point, which is less sensitive to colony color but requires even agar depth.
Laser counters use low-power lasers classified under IEC 60825-1 and typically keep the beam enclosed during normal operation. Operators need not wear laser eyewear if the enclosure is intact, but they should follow the safety instructions, avoid staring into the beam and not defeat the interlocks.
Very small or faint colonies may fall below the detection threshold, and uneven agar thickness changes the signal. Media that are highly opaque limit transmission, so laser scanning works best with transparent agar and colonies that clearly attenuate the beam.
It counts microbial colonies on agar plates and reports the result as colony-forming units. Laboratories use it for aerobic plate counts, coliform and E. coli testing, environmental monitoring and research, converting the plate count to CFU per millilitre or gram with the dilution factor.
A manual counter is an illuminated magnifier with a tally pen, so the operator decides which colonies to count. An automatic counter images or scans the plate and applies software rules, which improves consistency and speed but relies on validated thresholds for each medium.
ISO 7218 gives general rules for microbiological examinations, and ISO 4833-1 and 4833-2 cover colony counts at 30 degrees Celsius. ISO 11133 addresses culture media. Food laboratories often follow the FDA Bacteriological Analytical Manual in addition to these standards.
Related models