Fluorescence Colony Counter — product photo

Fluorescence Colony Counter

荧光菌落计数器

  • SKU COC-0004
  • Colony Counters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 62471 photobiological safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Detection principleFluorescence imaging or scanning
Excitation wavelengths365 nm, 460 nm (selectable)
Emission filters450 nm, 530 nm, 620 nm
Camera resolution5–12 MP
Plate formats55 mm, 90 mm
Minimum detectable colony0.1–0.3 mm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7218, ISO 4833-1, ISO 4833-2

What is the Fluorescence Colony Counter?

A fluorescence colony counter illuminates plates at specific wavelengths and detects colonies that fluoresce, which speeds enumeration on chromogenic and fluorogenic media. It suits food, water and clinical laboratories using selective or fluorogenic agars.

What is the Fluorescence Colony Counter?

A fluorescence colony counter illuminates plates at specific wavelengths and detects colonies that fluoresce, which speeds enumeration on chromogenic and fluorogenic media. It suits food, water and clinical laboratories using selective or fluorogenic agars.

Overview

A fluorescence colony counter adds excitation light and emission filters to an imaging or scanning platform so that colonies carrying fluorescent markers are detected directly. Plates are illuminated with ultraviolet or blue light, and targets such as E. coli on fluorogenic media, or green fluorescent protein labeled strains, emit at longer wavelengths that a filtered camera records. The resulting contrast allows detection of small colonies earlier than visible-light counting and separates target organisms from background flora. Software counts fluorescent objects, can combine fluorescence and visible channels to confirm morphology, and stores both images. Because signal depends on medium formulation and incubation time, each assay is validated against reference methods. Ultraviolet illumination requires eye and skin protection and controlled exposure.

How does it work?

Automated colony counting replaces the naked-eye tally with a sensor and software. A plate is placed on a backlit or dark-field stage and a camera captures a high-resolution image. Software applies thresholding and brightness or color segmentation to separate colonies from the agar background, and size and circularity filters remove bubbles, dust and cracks. Counts are reported as colony-forming units and converted to CFU per millilitre or gram using the dilution. Laser counters scan with a moving beam and detect colonies by light attenuation, which avoids ambiguity from similar-colored growth, while fluorescence counters excite labeled or fluorogenic targets and read the emitted light. Many instruments estimate the number of merged colonies, flag plates outside the statistical counting range, and export images and results for review.

What are the key features?

  • Excitation at 365 nm or 460 nm with matched emission filters
  • Detects target colonies on fluorogenic or chromogenic media
  • Dual fluorescence and visible-light channels
  • Earlier detection of small fluorescent colonies
  • Image and count storage with method templates

What are the technical specifications?

A typical fluorescence colony counter configuration offers detection principle of Fluorescence imaging or scanning, excitation wavelengths of 365 nm, 460 nm (selectable), emission filters of 450 nm, 530 nm, 620 nm, camera resolution of 5–12 MP, plate formats of 55 mm, 90 mm and minimum detectable colony of 0.1–0.3 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Fluorescence Colony Counter is used in rapid E. coli and coliform testing, food and beverage microbiological testing, water quality monitoring, clinical microbiology and research with labeled strains. Across the wider Colony Counters class, laboratories also deploy it for food and beverage microbiological testing, pharmaceutical environmental monitoring and water and wastewater analysis.

Which standards and certifications apply?

Relevant standards and methods include ISO 7218, ISO 4833-1, ISO 4833-2, ISO 11133, FDA BAM Chapter 3 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 62471 photobiological safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the counter on a stable bench away from direct sunlight, which changes illumination and thresholds. Keep the stage and optics clean, and follow the manufacturer interval for lamp or LED output checks. Verify performance with reference plates or a printed counting template and record results, because a drifting camera or dirty lens shifts counts. Before routine use, compare automated results with manual counts on typical media and organisms. For regulated laboratories, define who reviews flagged images, retain original images with the reported count, and place software updates under change control. Electrical safety follows IEC 61010-1.

How do I select the right Fluorescence Colony Counter?

Choose a fluorescence counter when you use chromogenic or fluorogenic media and need early or specific detection. In an RFQ confirm excitation and emission wavelengths, medium compatibility, safety interlocking, and whether dual-channel imaging or a specific validated organism panel is required.

How does it compare with other Colony Counters variants?

Match the counter to your plate types and throughput before comparing prices. Low-volume work with standard 90 mm dishes is well served by an illuminated manual counter, while routine high volume justifies an automated system. Confirm the plate formats accepted, including 55 mm contact plates, 90 mm and 150 mm dishes, and any compact dry or film plates you use. Check the detection principle, because color-based imaging is fast while laser scanning better separates colonies of similar hue, and fluorescence is needed for chromogenic or fluorogenic media. Look for statistics that follow ISO 7218 and recognized compendial guidance, including counting-range limits and treatment of spreading growth. Consider image retention, LIMS export and validation against manual counts on your own plates.

Full specifications

Full specifications
Detection principleFluorescence imaging or scanning
Excitation wavelengths365 nm, 460 nm (selectable)
Emission filters450 nm, 530 nm, 620 nm
Camera resolution5–12 MP
Plate formats55 mm, 90 mm
Minimum detectable colony0.1–0.3 mm
Analysis time3–15 s per plate
Data outputFluorescence image, CSV, LIMS export
UV safetyInterlocked light shield

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Rapid E. coli and coliform testing
  • Food and beverage microbiological testing
  • Water quality monitoring
  • Clinical microbiology
  • Research with labeled strains

Key features

  • Excitation at 365 nm or 460 nm with matched emission filters
  • Detects target colonies on fluorogenic or chromogenic media
  • Dual fluorescence and visible-light channels
  • Earlier detection of small fluorescent colonies
  • Image and count storage with method templates

Frequently asked questions about Fluorescence Colony Counter

It detects any colony that produces fluorescence under the instrument's excitation light, such as E. coli on fluorogenic media, coliforms on chromogenic agars and strains expressing fluorescent proteins. Each medium and target must be validated for reliable enumeration.