Skip to main content
Lab Manufacturers China
Closed-Loop Laboratory Circulation Pump — product photo

Closed-Loop Laboratory Circulation Pump

闭环实验室循环泵

  • SKU CIP-0006
  • Circulation Pumps
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Flow range1 mL/min–10 L/min
Max pressure0.5–4 bar
Hold-up volumeLow, application dependent
Wetted materialPTFE, PFA or stainless steel
Head typeGear, peristaltic or magnetic drive
ControlClosed-loop flow or pressure
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1

What is the Closed-Loop Laboratory Circulation Pump?

A closed-loop laboratory circulation pump maintains flow through a sealed circuit for sampling, dilution and online analysis. It avoids external contamination, keeps sample conditions constant during long measurement runs and reduces sample consumption.

What is the Closed-Loop Laboratory Circulation Pump?

A closed-loop laboratory circulation pump maintains flow through a sealed circuit for sampling, dilution and online analysis. It avoids external contamination, keeps sample conditions constant during long measurement runs and reduces sample consumption.

Overview

The closed-loop circulation pump is designed for systems where fluid must recirculate without exposure to air or the environment. It uses a gear, peristaltic or magnetic-drive head with low internal volume and materials suited to the sample, and it feeds instruments such as online spectrometers, particle counters or titration systems from a sealed reservoir or process line. Flow ranges from a few milliliters per minute in analytical loops to several liters per minute in pilot systems. A key feature is low hold-up volume, so the response to changes in the reservoir is fast and little sample is consumed. Some models include flow or pressure sensors and closed-loop control to hold flow steady despite changing resistance. The seal-free or isolated design prevents cross-contamination and protects both the sample and the instrument, and it supports continuous monitoring over hours or days.

How does it work?

A circulation pump uses a centrifugal or gear impeller to push fluid through a closed loop at a controlled flow rate. The fluid passes through a heated or refrigerated reservoir, then to the application's jacket or heat exchanger, and returns to the reservoir. A temperature sensor measures the bath or the return line, and a PID controller adjusts the heater or refrigeration compressor to hold the setpoint. Pump pressure must be enough to overcome the resistance of the loop, tubing and the application, and flow determines how quickly heat is transferred. Key components are the reservoir, heater, compressor or thermoelectric module, circulation pump, temperature sensor and controller. Cooling capacity and temperature range define the envelope; pump pressure and flow define the loop performance. Some units also offer external temperature control with a probe at the application.

What are the key features?

  • Sealed circuit to avoid air and environmental exposure
  • Low hold-up volume for fast response
  • Gear, peristaltic or magnetic-drive head options
  • Flow from a few mL/min to several L/min
  • Flow or pressure sensing with closed-loop control
  • Isolated design to prevent cross-contamination

What are the technical specifications?

A typical closed-loop laboratory circulation pump configuration offers flow range of 1 mL/min–10 L/min, max pressure of 0.5–4 bar, hold-up volume of Low, application dependent, wetted material of PTFE, PFA or stainless steel, head type of Gear, peristaltic or magnetic drive and control of Closed-loop flow or pressure. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Closed-Loop Laboratory Circulation Pump is used in online analysis sample loops, continuous flow monitoring, pilot system recirculation, dilution and sampling circuits and closed reactor feeding. Across the wider Circulation Pumps class, laboratories also deploy it for reactor jacket temperature control, spectrometer and detector cooling and laser and optics thermal management.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, ISO 9001 and GB 4793.1. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Use only the recommended fluid and change it periodically, because algae, scale and contaminants reduce heat transfer and can block the loop. Keep the reservoir above the minimum level to avoid pump cavitation and heater damage. Insulate external lines to reduce condensation and heat loss, and use the shortest practical tubing with few restrictions. Vent the loop to release trapped air before setting the controller, because air pockets cause temperature oscillation. Place the unit where ambient heat and dust are low, and clean the condenser or air filter on schedule. Follow IEC 61010-1 for electrical safety and check the pressure rating of the application loop before running at high pump pressure. Record setpoint, fluid and calibration data for traceability.

How do I select the right Closed-Loop Laboratory Circulation Pump?

Choose a closed-loop pump when sample integrity, low hold-up volume and continuous flow matter, such as online monitoring. For simple transfer, a basic peristaltic or diaphragm pump is sufficient. In the RFQ, state flow, pressure, sample compatibility, loop volume and control needs.

How does it compare with other Circulation Pumps variants?

Begin with the temperature range and the cooling or heating capacity required at your working temperature, not at the lowest rating. Then check pump flow and pressure, because a high-capacity bath with a weak pump may not circulate adequately through a restrictive jacket or long tubing run. Choose the reservoir volume for the thermal mass and stability you need, and decide between internal control at the bath and external control at the application. Match wetted materials to the fluid; water is standard, but glycol mixtures extend the low-temperature range, and some applications need silicone oil. Consider noise, footprint, drain and fill access, and whether a pressure or flow indicator is included. For unattended operation, look for low-level protection, over-temperature cutout and remote alarm contacts.

Full specifications

Full specifications
Flow range1 mL/min–10 L/min
Max pressure0.5–4 bar
Hold-up volumeLow, application dependent
Wetted materialPTFE, PFA or stainless steel
Head typeGear, peristaltic or magnetic drive
ControlClosed-loop flow or pressure
SensorsOptional flow or pressure
Temperature range5–80 °C
Connection1/4 in or 6 mm tubing
Power supply220–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Online analysis sample loops
  • Continuous flow monitoring
  • Pilot system recirculation
  • Dilution and sampling circuits
  • Closed reactor feeding

Key features

  • Sealed circuit to avoid air and environmental exposure
  • Low hold-up volume for fast response
  • Gear, peristaltic or magnetic-drive head options
  • Flow from a few mL/min to several L/min
  • Flow or pressure sensing with closed-loop control
  • Isolated design to prevent cross-contamination

Frequently asked questions about Closed-Loop Laboratory Circulation Pump

It means less sample is consumed and the loop responds quickly when conditions change. This matters in online monitoring and dilution circuits where delays distort the measurement.

Immersion Circulator — product photo

Immersion Circulator

浸入式循环器

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Closed-Loop Laboratory Circulation Pump

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote