Magnetic-Drive Centrifugal Circulation Pump
磁力驱动离心循环泵
- SKU CIP-0005
- Circulation Pumps
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Flow rate | 5–100 L/min |
|---|---|
| Max head | 10–20 m |
| Wetted material | PP, PVDF, PTFE or stainless steel |
| Max temperature | 80–120 °C depending on material |
| Seal type | Sealless magnetic drive |
| Self-priming | No, flooded suction required |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1
What is the Magnetic-Drive Centrifugal Circulation Pump?
A magnetic-drive centrifugal circulation pump moves fluid with a magnetically coupled impeller and no shaft seal, avoiding leaks. It is used for corrosive, hot or high-purity liquid circulation in many laboratory and process systems.
What is the Magnetic-Drive Centrifugal Circulation Pump?
A magnetic-drive centrifugal circulation pump moves fluid with a magnetically coupled impeller and no shaft seal, avoiding leaks. It is used for corrosive, hot or high-purity liquid circulation in many laboratory and process systems.
Overview
The magnetic-drive pump couples the motor to the impeller through magnets, so there is no rotating shaft penetrating the housing and no dynamic seal. This eliminates the main leak path, which matters for corrosive, toxic or expensive fluids and for high-purity applications where contamination must be avoided. Flow ranges from about 5 to 100 liters per minute, with heads up to 10 to 20 meters depending on the model. Wetted parts are available in polypropylene, PVDF, PTFE or stainless steel. The pump is compact and quiet, runs continuously without maintenance beyond occasional inspection, and resists many acids, bases and solvents. Because it is not self-priming and cannot run dry for long, it is typically installed in a flooded loop. It is used in recirculating baths, closed-loop reactor systems, filtration and purification rigs.
How does it work?
A circulation pump uses a centrifugal or gear impeller to push fluid through a closed loop at a controlled flow rate. The fluid passes through a heated or refrigerated reservoir, then to the application's jacket or heat exchanger, and returns to the reservoir. A temperature sensor measures the bath or the return line, and a PID controller adjusts the heater or refrigeration compressor to hold the setpoint. Pump pressure must be enough to overcome the resistance of the loop, tubing and the application, and flow determines how quickly heat is transferred. Key components are the reservoir, heater, compressor or thermoelectric module, circulation pump, temperature sensor and controller. Cooling capacity and temperature range define the envelope; pump pressure and flow define the loop performance. Some units also offer external temperature control with a probe at the application.
What are the key features?
- Magnetically coupled impeller with no shaft seal
- No dynamic seal, eliminating the main leak path
- Flow of about 5–100 L/min and heads to 10–20 m
- Wetted parts in PP, PVDF, PTFE or stainless steel
- Compact, quiet and suited to continuous running
- Resistant to many acids, bases and solvents
What are the technical specifications?
A typical magnetic-drive centrifugal circulation pump configuration offers flow rate of 5–100 L/min, max head of 10–20 m, wetted material of PP, PVDF, PTFE or stainless steel, max temperature of 80–120 °C depending on material, seal type of Sealless magnetic drive and self-priming of No, flooded suction required. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Magnetic-Drive Centrifugal Circulation Pump is used in corrosive liquid circulation, closed-loop reactor cooling, high-purity water systems, filtration and purification rigs and recirculating bath loops. Across the wider Circulation Pumps class, laboratories also deploy it for reactor jacket temperature control, spectrometer and detector cooling and laser and optics thermal management.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, ISO 9001 and GB 4793.1. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Use only the recommended fluid and change it periodically, because algae, scale and contaminants reduce heat transfer and can block the loop. Keep the reservoir above the minimum level to avoid pump cavitation and heater damage. Insulate external lines to reduce condensation and heat loss, and use the shortest practical tubing with few restrictions. Vent the loop to release trapped air before setting the controller, because air pockets cause temperature oscillation. Place the unit where ambient heat and dust are low, and clean the condenser or air filter on schedule. Follow IEC 61010-1 for electrical safety and check the pressure rating of the application loop before running at high pump pressure. Record setpoint, fluid and calibration data for traceability.
How do I select the right Magnetic-Drive Centrifugal Circulation Pump?
Choose a magnetic-drive pump when leaks are unacceptable or the fluid is corrosive, hot or high-purity. For self-priming or dry-run duties, a diaphragm pump is more suitable. In the RFQ, state flow, head, fluid, temperature and connection type.
How does it compare with other Circulation Pumps variants?
Begin with the temperature range and the cooling or heating capacity required at your working temperature, not at the lowest rating. Then check pump flow and pressure, because a high-capacity bath with a weak pump may not circulate adequately through a restrictive jacket or long tubing run. Choose the reservoir volume for the thermal mass and stability you need, and decide between internal control at the bath and external control at the application. Match wetted materials to the fluid; water is standard, but glycol mixtures extend the low-temperature range, and some applications need silicone oil. Consider noise, footprint, drain and fill access, and whether a pressure or flow indicator is included. For unattended operation, look for low-level protection, over-temperature cutout and remote alarm contacts.
Full specifications
| Flow rate | 5–100 L/min |
|---|---|
| Max head | 10–20 m |
| Wetted material | PP, PVDF, PTFE or stainless steel |
| Max temperature | 80–120 °C depending on material |
| Seal type | Sealless magnetic drive |
| Self-priming | No, flooded suction required |
| Motor power | 60–750 W |
| Connection | Threaded or hose barb |
| Duty cycle | Continuous |
| Power supply | 220–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Corrosive liquid circulation
- Closed-loop reactor cooling
- High-purity water systems
- Filtration and purification rigs
- Recirculating bath loops
Key features
- Magnetically coupled impeller with no shaft seal
- No dynamic seal, eliminating the main leak path
- Flow of about 5–100 L/min and heads to 10–20 m
- Wetted parts in PP, PVDF, PTFE or stainless steel
- Compact, quiet and suited to continuous running
- Resistant to many acids, bases and solvents
Frequently asked questions about Magnetic-Drive Centrifugal Circulation Pump
Without a dynamic seal, there is no leak path along a rotating shaft. This reduces maintenance, protects operators from hazardous fluids and prevents contamination of high-purity liquids.
Not for long. The pumped fluid lubricates and cools the bearing surfaces, so running dry causes rapid wear. Keep the suction flooded and add a low-level or flow switch for protection.
Material dependent: polypropylene to about 80 degrees Celsius, PVDF and PTFE to higher temperatures, and stainless steel beyond that. Confirm the gasket and O-ring ratings for your setpoint.
Use the capacity quoted at your working temperature, not at the lowest temperature, and add margin for line losses and the application heat load. Capacity falls as temperature decreases, so ambient conditions matter.
The pump must overcome resistance from the application jacket, tubing and fittings. A pump with high flow but low pressure may circulate poorly through restrictive paths, so check both the flow and pressure curves.
Yes, a glycol and water mixture extends the working range below zero and reduces freezing risk. It lowers heat transfer slightly and needs periodic replacement, so confirm the concentration for your target temperature.