OEM Syringe Pump Module
OEM 注射泵模块
- SKU SYP-0006
- Syringe Pumps
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Flow range | 0.1 µL/min–40 mL/min |
|---|---|
| Syringe sizes | 0.5 µL–25 mL |
| Host interface | RS232/RS485, CAN or analog |
| Supply voltage | 12 or 24 V DC |
| Max force | 20–90 N |
| Motor type | Stepper motor |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 60601-2-24, IEC 61326-1
What is the OEM Syringe Pump Module?
An OEM syringe pump module is a drive and controller designed for integration into instruments and automated systems. It provides accurate syringe-based dosing with a defined electrical and mechanical interface for manufacturers.
What is the OEM Syringe Pump Module?
An OEM syringe pump module is a drive and controller designed for integration into instruments and automated systems. It provides accurate syringe-based dosing with a defined electrical and mechanical interface for manufacturers.
Overview
The OEM syringe pump module is sold without a housing, keypad or display, so instrument builders can embed it in their own enclosure and control it through their firmware. It includes the motor, lead screw, syringe holder and a controller board with a serial, CAN or analog interface. Flow ranges and force ratings are specified for the target application, from microliter dosing in diagnostic analyzers to milliliter transfer in sample preparation robots. Manufacturers value the module for its repeatability, small size and long service life, and because it can be validated as part of the host instrument. Documentation typically includes interface protocols, mechanical drawings and reliability data. The module may be supplied with or without the syringe, and standard holders accept common syringe brands and sizes.
How does it work?
A syringe pump holds a syringe in a clamp and advances the plunger with a lead screw turned by a stepper motor. Flow rate equals the plunger cross-sectional area multiplied by the linear speed, so a small syringe gives a very low flow and a large syringe gives a higher flow at the same motor speed. Because the drive is positive displacement and continuous, flow is smooth and independent of back pressure until the motor stalls, which makes these pumps valuable for microfluidics, chromatography and infusion. Typical components are the drive mechanism, syringe clamp, control electronics and often a pressure sensor or valve. Pumps range from microliter syringes delivering nanoliters per minute to large syringes delivering hundreds of milliliters per minute, and multi-syringe configurations add parallel or mixing functions.
What are the key features?
- Drive and controller without housing for embedding
- Serial, CAN or analog host interface
- Specified flow range and force for the application
- Standard holders for common syringe brands
- Documentation with protocols and drawings
- Long service life for continuous instrument use
What are the technical specifications?
A typical oem syringe pump module configuration offers flow range of 0.1 µL/min–40 mL/min, syringe sizes of 0.5 µL–25 mL, host interface of RS232/RS485, CAN or analog, supply voltage of 12 or 24 V DC, max force of 20–90 N and motor type of Stepper motor. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The OEM Syringe Pump Module is used in diagnostic analyzer integration, automated sample preparation robots, analytical instrument dosing, point-of-care device fluidics and laboratory automation platforms. Across the wider Syringe Pumps class, laboratories also deploy it for microfluidic and lab-on-chip flow control, continuous reagent and nutrient infusion and chromatography sample injection.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 60601-2-24, IEC 61326-1, ISO 9001 and GB 4793.1. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Prime the syringe and line to remove air, because bubbles compress and introduce flow error. Keep the line short and rigid to minimize compliance, which otherwise delays response and lowers accuracy at high pressure. Note the syringe size and manufacturer, since bore tolerances affect delivered volume, and recalibrate whenever the syringe type changes. Do not exceed the pressure rating of the syringe or the drive, and use a pressure sensor or stall detection on restricted systems. Avoid leaving highly viscous or crystallizing fluids in the syringe, and clean the plunger and seal regularly. Follow IEC 61010-1 for electrical safety. For regulated infusion, verify flow gravimetrically and record calibration data, since the pump is often a critical control in the method.
How do I select the right OEM Syringe Pump Module?
Choose an OEM module when you are building an instrument and need a documented, integrable syringe drive rather than a standalone pump. For bench-top manual use, a complete pump with keypad is more practical. In the RFQ, state interface, voltage, flow range, force and documentation needs.
How does it compare with other Syringe Pumps variants?
Start with the required flow rate and syringe size, then choose the drive resolution and speed range that covers it. For nanoliter to microliter flows, a microfluidic pump with a small syringe gives the best stability. For high pressure, choose refractory or stainless steel syringes and a reinforced drive, and note the maximum pressure and any valves needed. Decide how many syringes must run at once: dual and multi-channel pumps allow parallel infusion and mixing. Check whether the pump supports programmable profiles such as ramps, pulses and refill cycles, and whether it can be controlled by software or external signals for integration. Verify wetted materials for chemical compatibility and choose the syringe type, since glass, plastic and steel each have limits. Calibration and flow verification complete the selection.
Full specifications
| Flow range | 0.1 µL/min–40 mL/min |
|---|---|
| Syringe sizes | 0.5 µL–25 mL |
| Host interface | RS232/RS485, CAN or analog |
| Supply voltage | 12 or 24 V DC |
| Max force | 20–90 N |
| Motor type | Stepper motor |
| Position resolution | Up to 6,400 steps/rev |
| Dimensions | Application specific |
| Service life | Up to 5 million steps |
| Documentation | Protocol and drawings supplied |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Diagnostic analyzer integration
- Automated sample preparation robots
- Analytical instrument dosing
- Point-of-care device fluidics
- Laboratory automation platforms
Key features
- Drive and controller without housing for embedding
- Serial, CAN or analog host interface
- Specified flow range and force for the application
- Standard holders for common syringe brands
- Documentation with protocols and drawings
- Long service life for continuous instrument use
Frequently asked questions about OEM Syringe Pump Module
Through your host controller using the provided serial, CAN or analog interface. Commands set flow, volume and direction, and the module reports status and position.
Yes, modules can be ordered alone or with syringes and holders. Confirm the syringe brand and size to match your assay volumes and the module force rating.
Typically interface protocols, mechanical drawings, electrical specifications and reliability or life-test data. This supports design verification and regulatory submissions for the host instrument.
The lead screw advances the plunger continuously, so there is no peristaltic pulsation or valve cycle. With microstepping, flow is nearly pulseless, which suits microfluidics and infusion where smooth delivery matters.
From nanoliters per minute with a small syringe to hundreds of milliliters per minute with a large syringe. Flow depends on syringe cross-section and motor speed, so syringe choice sets the working range.
Prime the syringe and tubing carefully, tap out visible bubbles and use a short, rigid line. Air pockets compress under pressure, which delays flow and lowers the delivered volume.