Peltier Cooled Incubator — product photo

Peltier Cooled Incubator

珀尔帖低温培养箱

  • SKU CIN-0002
  • Cooling Incubators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume20–150 L
Temperature range5–60 C
Temperature uniformity±0.5–1 C
Temperature fluctuation±0.2 C
Cooling systemPeltier thermoelectric
RefrigerantNone
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880

What is the Peltier Cooled Incubator?

A Peltier cooled incubator uses thermoelectric modules to cool and heat without refrigerant, in a compact and quiet unit. It is chosen for benchtop work where space, noise and refrigerant use are concerns.

What is the Peltier Cooled Incubator?

A Peltier cooled incubator uses thermoelectric modules to cool and heat without refrigerant, in a compact and quiet unit. It is chosen for benchtop work where space, noise and refrigerant use are concerns.

Overview

The Peltier incubator uses thermoelectric modules, which move heat when current passes through them and reverse direction when polarity changes, so one set of modules provides both heating and cooling. There is no compressor, refrigerant or vibration, and the unit is compact and quiet, which suits benchtop and small-room installations. Temperature typically spans 5 to 60 C, though efficiency drops at the cold end, so the range may be narrower at large volumes. Uniformity of plus or minus 0.5 to 1 C is reached with forced circulation. Digital control, timers and data output are standard. Power use per degree of cooling is higher than a compressor, so Peltier designs are best for small chambers and moderate cooling loads.

How does it work?

A cooling incubator adds a refrigeration circuit or Peltier modules to a heated, insulated chamber. A compressor circuit evaporates refrigerant in a coil, absorbing heat, and condenses it outside; Peltier modules move heat electrically with no refrigerant, which suits smaller chambers. A Pt100 or thermistor sensor feeds a PID controller that coordinates heating and cooling to hold the setpoint from below ambient to about 60 C, switching between modes as needed. Forced-air circulation keeps uniformity within plus or minus 0.5 to 1 C, and defrost cycles prevent ice build-up on the evaporator, which would block airflow. Chamber walls are stainless steel, and doors carry heaters or heated frames to avoid condensation at low temperature. Programmable controllers, alarms and data logging support stability and shelf-life methods.

What are the key features?

  • Thermoelectric modules for heating and cooling
  • No refrigerant, compressor or vibration
  • Compact and quiet benchtop construction
  • Temperature range of about 5 to 60 C
  • Uniformity of ±0.5 to 1 C with forced circulation
  • Digital control with timer and data output

What are the technical specifications?

A typical peltier cooled incubator configuration offers chamber volume of 20–150 L, temperature range of 5–60 C, temperature uniformity of ±0.5–1 C, temperature fluctuation of ±0.2 C, cooling system of Peltier thermoelectric and refrigerant of None. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Peltier Cooled Incubator is used in benchtop enzyme assays, small stability studies, sample conditioning in quiet rooms and clinical and molecular work requiring low vibration. Across the wider Cooling Incubators class, laboratories also deploy it for enzyme and biochemical assays at low temperature, stability and shelf-life studies and sample storage and conditioning.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 9001 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the incubator where it can reject heat freely, with clearance around the condenser and vents, and avoid confined cabinets that raise ambient temperature. Keep the condenser fins clean, since dust reduces cooling and increases power use. Do not open the door at low temperature more than necessary, because ice forms on the evaporator and frames. Defrost on the recommended schedule, and drain condensate so it does not pool. Verify temperature at the working setpoint, not at a single midpoint, and calibrate with a reference probe at several positions. Check door heaters, gaskets and the refrigeration system during scheduled service, and keep records.

How do I select the right Peltier Cooled Incubator?

Select the Peltier incubator for compact benchtop cooling without refrigerant, noise or vibration, and for moderate cooling loads. Refrigerated units are more efficient and reach lower temperatures at larger volumes. In the RFQ, specify volume, temperature range, uniformity, vibration limits and data output.

How does it compare with other Cooling Incubators variants?

Choose a cooling incubator whenever the setpoint is at or below room temperature, because heating-only incubators cannot reach it, especially in warm rooms. Define the temperature range first, from a lower limit near 0 C for most units to lower values for specialized models, and decide whether you need humidity control. Select a compressor design for larger chambers and faster cooling, or Peltier for compact, quiet units without refrigerant. Match chamber volume to the load and check uniformity at the working temperature, since low-temperature operation widens gradients. Consider defrost strategy, condensation control, programmability and data logging, and confirm power, ventilation and heat rejection requirements.

Full specifications

Full specifications
Chamber volume20–150 L
Temperature range5–60 C
Temperature uniformity±0.5–1 C
Temperature fluctuation±0.2 C
Cooling systemPeltier thermoelectric
RefrigerantNone
Reversible operationHeating and cooling
Shelves supplied2–4
Cooling power100–500 W
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Benchtop enzyme assays
  • Small stability studies
  • Sample conditioning in quiet rooms
  • Clinical and molecular work requiring low vibration

Key features

  • Thermoelectric modules for heating and cooling
  • No refrigerant, compressor or vibration
  • Compact and quiet benchtop construction
  • Temperature range of about 5 to 60 C
  • Uniformity of ±0.5 to 1 C with forced circulation
  • Digital control with timer and data output

Frequently asked questions about Peltier Cooled Incubator

Current through a thermoelectric module carries heat from one face to the other, cooling the chamber side and warming the outside. Reversing the current reverses the heat flow, so the same module provides both cooling and heating without any refrigerant.

Request a quotation for the Peltier Cooled Incubator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.