Refrigerated Cooled Incubator
压缩机制冷培养箱
- SKU CIN-0001
- Cooling Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–500 L |
|---|---|
| Temperature range | 0–60 C |
| Temperature uniformity | ±0.5–1 C |
| Temperature fluctuation | ±0.2 C |
| Cooling system | Compressor, air-cooled |
| Refrigerant | R134a or R290 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880
What is the Refrigerated Cooled Incubator?
A refrigerated cooled incubator uses a compressor circuit to hold temperatures from 0 to 60 C precisely. It is the standard choice for stability studies, enzyme work and incubation near or below room temperature.
What is the Refrigerated Cooled Incubator?
A refrigerated cooled incubator uses a compressor circuit to hold temperatures from 0 to 60 C precisely. It is the standard choice for stability studies, enzyme work and incubation near or below room temperature.
Overview
The refrigerated incubator pairs a compressor refrigeration circuit with heating elements and a PID controller that selects heating or cooling to hold the setpoint from about 0 to 60 C. Forced-air circulation keeps uniformity within plus or minus 0.5 to 1 C. Defrost cycles clear ice from the evaporator, and door heaters or heated frames prevent condensation. Chambers run from about 50 to 500 liters, with stainless steel interiors and shelves or trays. Digital controllers with timers and alarms are standard, and programmable versions log data for stability and shelf-life methods. Compressors deliver strong cooling even in warm rooms, which makes this the workhorse design for cooled incubation where capacity and reliability matter.
How does it work?
A cooling incubator adds a refrigeration circuit or Peltier modules to a heated, insulated chamber. A compressor circuit evaporates refrigerant in a coil, absorbing heat, and condenses it outside; Peltier modules move heat electrically with no refrigerant, which suits smaller chambers. A Pt100 or thermistor sensor feeds a PID controller that coordinates heating and cooling to hold the setpoint from below ambient to about 60 C, switching between modes as needed. Forced-air circulation keeps uniformity within plus or minus 0.5 to 1 C, and defrost cycles prevent ice build-up on the evaporator, which would block airflow. Chamber walls are stainless steel, and doors carry heaters or heated frames to avoid condensation at low temperature. Programmable controllers, alarms and data logging support stability and shelf-life methods.
What are the key features?
- Compressor refrigeration with heating and PID control
- Temperature range of 0 to 60 C
- Uniformity of ±0.5 to 1 C with forced air
- Automatic defrost cycle
- Door heaters or heated frames to limit condensation
- Chamber volume of 50 to 500 liters
What are the technical specifications?
A typical refrigerated cooled incubator configuration offers chamber volume of 50–500 L, temperature range of 0–60 C, temperature uniformity of ±0.5–1 C, temperature fluctuation of ±0.2 C, cooling system of Compressor, air-cooled and refrigerant of R134a or R290. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Refrigerated Cooled Incubator is used in stability and shelf-life studies, enzyme and biochemical assays, sample conditioning and storage, microbial culture at 20 to 30 C and food quality testing. Across the wider Cooling Incubators class, laboratories also deploy it for enzyme and biochemical assays at low temperature, stability and shelf-life studies and sample storage and conditioning.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 9001 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the incubator where it can reject heat freely, with clearance around the condenser and vents, and avoid confined cabinets that raise ambient temperature. Keep the condenser fins clean, since dust reduces cooling and increases power use. Do not open the door at low temperature more than necessary, because ice forms on the evaporator and frames. Defrost on the recommended schedule, and drain condensate so it does not pool. Verify temperature at the working setpoint, not at a single midpoint, and calibrate with a reference probe at several positions. Check door heaters, gaskets and the refrigeration system during scheduled service, and keep records.
How do I select the right Refrigerated Cooled Incubator?
Select the refrigerated cooled incubator for most below-ambient work where capacity and strong cooling matter. Peltier units suit compact, quiet installations. In the RFQ, specify volume, temperature range, uniformity at setpoint, defrost method, shelves and data logging needs.
How does it compare with other Cooling Incubators variants?
Choose a cooling incubator whenever the setpoint is at or below room temperature, because heating-only incubators cannot reach it, especially in warm rooms. Define the temperature range first, from a lower limit near 0 C for most units to lower values for specialized models, and decide whether you need humidity control. Select a compressor design for larger chambers and faster cooling, or Peltier for compact, quiet units without refrigerant. Match chamber volume to the load and check uniformity at the working temperature, since low-temperature operation widens gradients. Consider defrost strategy, condensation control, programmability and data logging, and confirm power, ventilation and heat rejection requirements.
Full specifications
| Chamber volume | 50–500 L |
|---|---|
| Temperature range | 0–60 C |
| Temperature uniformity | ±0.5–1 C |
| Temperature fluctuation | ±0.2 C |
| Cooling system | Compressor, air-cooled |
| Refrigerant | R134a or R290 |
| Defrost | Automatic or manual |
| Shelves supplied | 3–6 |
| Cooling power | 300–1500 W |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Stability and shelf-life studies
- Enzyme and biochemical assays
- Sample conditioning and storage
- Microbial culture at 20 to 30 C
- Food quality testing
Key features
- Compressor refrigeration with heating and PID control
- Temperature range of 0 to 60 C
- Uniformity of ±0.5 to 1 C with forced air
- Automatic defrost cycle
- Door heaters or heated frames to limit condensation
- Chamber volume of 50 to 500 liters
Frequently asked questions about Refrigerated Cooled Incubator
Most reach about 0 C, and some go to -10 C or slightly lower with a larger refrigeration system. The achievable minimum depends on ambient temperature, since cooling capacity falls as the room warms and heat rejection becomes harder.
Automatic cycles run every few hours at low setpoints, lasting minutes, while manual units require periodic shutdowns. Frost on the evaporator blocks airflow and distorts uniformity, so the schedule should be followed and the drain checked.
Yes. It includes heating elements, so the same unit covers below-ambient and above-ambient setpoints, typically 0 to 60 C. The PID controller chooses heating or cooling, which makes it versatile across stability and culture applications.
Because a standard incubator only heats. If the required setpoint is at or below room temperature, or the room is warm, a cooling incubator with refrigeration is needed to reach and hold it precisely. It also allows temperatures like 20 or 25 C in summer conditions.
Compressor refrigeration is efficient at larger volumes and can reach lower temperatures, but uses refrigerant and makes some noise and vibration. Peltier modules are compact, quiet and refrigerant-free but suit smaller chambers and use more power per degree of cooling.
Door heaters and heated frames keep glass and gaskets above the dew point, while scheduled defrost cycles melt ice from the evaporator. Condensate drains away so it does not pool, and airflow is maintained for uniform temperature.
Related models