Skip to main content
Lab Manufacturers China
Water-Jacketed CO2 Incubator — product photo

Water-Jacketed CO2 Incubator

水套式 CO2 培养箱

  • SKU COI-0002
  • CO2 Incubators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume50–200 L
Temperature rangeRT+5 to 55 C
Temperature uniformity±0.2–0.4 C
CO2 range0–20%
CO2 sensorInfrared (IR)
Humidity90–95% RH
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880

What is the Water-Jacketed CO2 Incubator?

A water-jacketed CO2 incubator uses a large water mass around the chamber to hold temperature very stably, even through power interruptions. It is chosen for sensitive cultures that must not see temperature swings.

What is the Water-Jacketed CO2 Incubator?

A water-jacketed CO2 incubator uses a large water mass around the chamber to hold temperature very stably, even through power interruptions. It is chosen for sensitive cultures that must not see temperature swings.

Overview

The water-jacketed incubator surrounds the inner chamber with a sealed water reservoir, so the large thermal mass damps temperature changes and holds the setpoint for hours if power fails. Uniformity is excellent, typically plus or minus 0.2 to 0.4 C, and recovery after door openings is steady. Temperature reaches 50 to 55 C, CO2 is controlled from 0 to 20 percent by an infrared sensor, and humidity runs near 90 to 95 percent. The trade-off is weight, since a full jacket holds many liters of water, and slower initial warm-up. Water fill and level maintenance are required, and some units monitor the jacket level. It suits cell banks, IVF and research laboratories where culture stability is paramount.

How does it work?

A CO2 incubator heats an insulated chamber to a setpoint, usually 37 C, and adds carbon dioxide from an external cylinder to hold the medium pH near 7.4 in bicarbonate buffers. An infrared or thermal-conductivity sensor measures CO2, and a PID loop opens a valve or modulates gas flow to correct deviations. Humidity is maintained near 90 to 95 percent by a water pan or an active humidity generator, which reduces evaporation and keeps osmolality stable. Air circulation may be natural, forced or designed as a gentle laminar flow to limit contamination spread. Door heaters reduce condensation on the glass, and over-temperature and CO2 alarms protect the culture. Interior surfaces are stainless steel or copper alloy, chosen for cleanability and antimicrobial behaviour, with gaskets that allow frequent decontamination.

What are the key features?

  • Sealed water jacket of large thermal mass
  • Uniformity of ±0.2 to 0.4 C
  • Holds temperature during power interruptions
  • Infrared CO2 control from 0 to 20 percent
  • Humidity near 90 to 95 percent
  • Jacket water-level monitoring on some models

What are the technical specifications?

A typical water-jacketed co2 incubator configuration offers chamber volume of 50–200 L, temperature range of RT+5 to 55 C, temperature uniformity of ±0.2–0.4 C, CO2 range of 0–20%, CO2 sensor of Infrared (IR) and humidity of 90–95% RH. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Water-Jacketed CO2 Incubator is used in cell banking and storage cultures, in vitro fertilization and embryo culture, research cell lines with strict stability needs and long-term culture experiments. Across the wider CO2 Incubators class, laboratories also deploy it for mammalian cell line culture, tissue and primary cell culture and in vitro fertilization and embryo work.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, USP <1116>, ISO 14644-1, ISO 17025 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the incubator in a stable location away from sunlight, draughts and heat sources, with space for the gas cylinder and regulator, and anchor cylinders so they cannot fall. Use instrument-grade CO2 and replace the water in the humidity pan with sterile distilled water regularly to avoid microbial growth. Decontaminate the chamber on a defined schedule, and monitor CO2 concentration, temperature and humidity daily, logging values. Verify temperature and CO2 with calibrated references at intervals and after service. Check door gaskets and filters for wear, keep the chamber loaded so temperature stays stable, and avoid stacking past the manufacturer's limit.

How do I select the right Water-Jacketed CO2 Incubator?

Select the water-jacketed incubator when temperature stability is the top priority and power interruptions are a concern, as in cell banking and IVF. Air-jacketed units are lighter and cheaper for routine work. In the RFQ, specify volume, jacket type and monitoring, CO2 sensor, humidity method and decontamination cycle.

How does it compare with other CO2 Incubators variants?

Choose a CO2 incubator when the culture needs a bicarbonate-buffered medium and high humidity, which is typical of mammalian and tissue culture. Decide the heating design first: air-jacketed units are simple and recover steadily, water-jacketed units hold temperature through long power interruptions, and direct-heat units warm and cool quickly. Then set chamber volume from flask count and check the CO2 range and sensor type, since infrared sensors resist humidity drift better than thermal-conductivity sensors. Consider humidity method, decontamination options such as high-temperature cycles, HEPA filtration and stacking. Confirm gas supply, alarm connectivity and power, and require validation support for regulated cell work.

Full specifications

Full specifications
Chamber volume50–200 L
Temperature rangeRT+5 to 55 C
Temperature uniformity±0.2–0.4 C
CO2 range0–20%
CO2 sensorInfrared (IR)
Humidity90–95% RH
Jacket typeWater
Jacket volume20–40 L
Temperature hold after power loss2–6 h
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cell banking and storage cultures
  • In vitro fertilization and embryo culture
  • Research cell lines with strict stability needs
  • Long-term culture experiments

Key features

  • Sealed water jacket of large thermal mass
  • Uniformity of ±0.2 to 0.4 C
  • Holds temperature during power interruptions
  • Infrared CO2 control from 0 to 20 percent
  • Humidity near 90 to 95 percent
  • Jacket water-level monitoring on some models

Frequently asked questions about Water-Jacketed CO2 Incubator

Typically two to six hours depending on ambient temperature, jacket volume and setpoint, since the large water mass releases stored heat slowly. This protects cultures from short power interruptions that would disturb an air-jacketed unit.

Related models

All CO2 Incubators

Request a quotation for the Water-Jacketed CO2 Incubator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote