High-Humidity CO2 Incubator
高湿度 CO2 培养箱
- SKU COI-0004
- CO2 Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–200 L |
|---|---|
| Temperature range | RT+5 to 55 C |
| Temperature uniformity | ±0.3–0.5 C |
| CO2 range | 0–20% |
| CO2 sensor | Infrared (IR) |
| Humidity | ≥95% RH |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880
What is the High-Humidity CO2 Incubator?
A high-humidity CO2 incubator actively maintains humidity near the dew point to minimize evaporation from open culture vessels. It is chosen for long experiments and open-dish work where medium concentration must stay stable.
What is the High-Humidity CO2 Incubator?
A high-humidity CO2 incubator actively maintains humidity near the dew point to minimize evaporation from open culture vessels. It is chosen for long experiments and open-dish work where medium concentration must stay stable.
Overview
This incubator emphasizes humidity control, using an active humidifier or a large heated water reservoir to hold chamber humidity at 95 percent or above. This minimizes evaporation from open dishes, coverslips and loosely capped flasks, keeping osmolality and solute concentration steady over long experiments. The chamber is designed to resist condensation, with door heaters and drainage so droplets do not fall onto cultures. Temperature reaches 50 to 55 C and CO2 is controlled from 0 to 20 percent by an infrared sensor. Recirculating HEPA filtration is common to reduce airborne contamination. Cleaning and water management are more demanding, since high humidity encourages microbial growth. It suits IVF, time-lapse imaging, primary cell work and multi-week experiments.
How does it work?
A CO2 incubator heats an insulated chamber to a setpoint, usually 37 C, and adds carbon dioxide from an external cylinder to hold the medium pH near 7.4 in bicarbonate buffers. An infrared or thermal-conductivity sensor measures CO2, and a PID loop opens a valve or modulates gas flow to correct deviations. Humidity is maintained near 90 to 95 percent by a water pan or an active humidity generator, which reduces evaporation and keeps osmolality stable. Air circulation may be natural, forced or designed as a gentle laminar flow to limit contamination spread. Door heaters reduce condensation on the glass, and over-temperature and CO2 alarms protect the culture. Interior surfaces are stainless steel or copper alloy, chosen for cleanability and antimicrobial behaviour, with gaskets that allow frequent decontamination.
What are the key features?
- Active humidification to 95 percent RH or above
- Corrosion-resistant chamber with drainage
- Door heaters to limit condensation
- Infrared CO2 control from 0 to 20 percent
- Recirculating HEPA filtration option
- Stable osmolality for open-dish work
What are the technical specifications?
A typical high-humidity co2 incubator configuration offers chamber volume of 50–200 L, temperature range of RT+5 to 55 C, temperature uniformity of ±0.3–0.5 C, CO2 range of 0–20%, CO2 sensor of Infrared (IR) and humidity of ≥95% RH. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Humidity CO2 Incubator is used in in vitro fertilization culture, time-lapse and live imaging, primary cell and organoid culture and multi-week experiments with open dishes. Across the wider CO2 Incubators class, laboratories also deploy it for mammalian cell line culture, tissue and primary cell culture and in vitro fertilization and embryo work.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, USP <1116>, ISO 14644-1, ISO 17025 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the incubator in a stable location away from sunlight, draughts and heat sources, with space for the gas cylinder and regulator, and anchor cylinders so they cannot fall. Use instrument-grade CO2 and replace the water in the humidity pan with sterile distilled water regularly to avoid microbial growth. Decontaminate the chamber on a defined schedule, and monitor CO2 concentration, temperature and humidity daily, logging values. Verify temperature and CO2 with calibrated references at intervals and after service. Check door gaskets and filters for wear, keep the chamber loaded so temperature stays stable, and avoid stacking past the manufacturer's limit.
How do I select the right High-Humidity CO2 Incubator?
Select the high-humidity incubator when evaporation from open vessels would change the medium, as in IVF, imaging and long experiments. Standard humidity is adequate for capped flasks. In the RFQ, specify humidity setpoint, chamber volume, CO2 sensor, HEPA option and cleaning access.
How does it compare with other CO2 Incubators variants?
Choose a CO2 incubator when the culture needs a bicarbonate-buffered medium and high humidity, which is typical of mammalian and tissue culture. Decide the heating design first: air-jacketed units are simple and recover steadily, water-jacketed units hold temperature through long power interruptions, and direct-heat units warm and cool quickly. Then set chamber volume from flask count and check the CO2 range and sensor type, since infrared sensors resist humidity drift better than thermal-conductivity sensors. Consider humidity method, decontamination options such as high-temperature cycles, HEPA filtration and stacking. Confirm gas supply, alarm connectivity and power, and require validation support for regulated cell work.
Full specifications
| Chamber volume | 50–200 L |
|---|---|
| Temperature range | RT+5 to 55 C |
| Temperature uniformity | ±0.3–0.5 C |
| CO2 range | 0–20% |
| CO2 sensor | Infrared (IR) |
| Humidity | ≥95% RH |
| Humidification | Active humidifier or heated reservoir |
| HEPA filtration | Optional recirculating |
| Door heater | Standard |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- In vitro fertilization culture
- Time-lapse and live imaging
- Primary cell and organoid culture
- Multi-week experiments with open dishes
Key features
- Active humidification to 95 percent RH or above
- Corrosion-resistant chamber with drainage
- Door heaters to limit condensation
- Infrared CO2 control from 0 to 20 percent
- Recirculating HEPA filtration option
- Stable osmolality for open-dish work
Frequently asked questions about High-Humidity CO2 Incubator
Typically 95 percent relative humidity or above, close to saturation at 37 C. Active humidifiers or heated reservoirs supply moisture continuously, so evaporation from open dishes and imaging chambers is minimized and osmolality stays stable.
Warm, wet surfaces encourage bacterial, mold and mycoplasma growth, and condensation carries contaminants downward. Frequent cleaning and decontamination, sterile water and drainage of pooled water are needed to prevent biofilm formation.
Door heaters, warmed walls and drainage channels keep surfaces slightly above the dew point or guide droplets away from cultures. Setting temperature and humidity together, and avoiding sudden changes, prevents heavy condensation on lids and dishes.
High humidity near 90 to 95 percent stops culture medium from evaporating, which would concentrate salts and change osmolality. Stable osmolality keeps cells healthy, especially in open dishes and long experiments where even modest evaporation would alter the medium.
An air jacket surrounds the chamber with an insulated air layer, giving simple construction and stable temperature. A water jacket uses a large water mass around the chamber, which holds temperature longer during power interruptions but adds weight and warm-up time.
Infrared sensors measure CO2 directly and resist changes in humidity and temperature, so they drift less and recover faster after door openings. Thermal-conductivity sensors are cheaper but depend on humidity and require more frequent calibration.