Programmable Cooled Incubator — product photo

Programmable Cooled Incubator

可编程低温培养箱

  • SKU CIN-0004
  • Cooling Incubators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume50–500 L
Temperature range0–60 C
Programs10–30
Segments per programUp to 30
Ramp rate0.1–5 C/min
Temperature uniformity±0.5–1 C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880

What is the Programmable Cooled Incubator?

A programmable cooled incubator follows stored multi-step temperature and humidity profiles, so stability and shelf-life cycles can be repeated. It is chosen when methods specify ramps, staged holds or documented environmental conditions.

What is the Programmable Cooled Incubator?

A programmable cooled incubator follows stored multi-step temperature and humidity profiles, so stability and shelf-life cycles can be repeated. It is chosen when methods specify ramps, staged holds or documented environmental conditions.

Overview

This incubator pairs refrigerated cooling with a multi-segment controller storing 10 to 30 programs of ramp, hold and cool steps, each with its own setpoint and duration. Methods that step between temperatures, cycle day and night conditions or ramp slowly to a target run automatically. Data logging records temperature, and often humidity, with timestamps through RS-485, USB or Ethernet for validation and traceability, and real-time curves are shown on the display. Chambers run 50 to 500 liters with uniformity of plus or minus 0.5 to 1 C across 0 to 60 C. Cooling and heating switch automatically, and defrost is scheduled outside critical stages. It suits regulated stability studies and research requiring reproducible thermal histories.

How does it work?

A cooling incubator adds a refrigeration circuit or Peltier modules to a heated, insulated chamber. A compressor circuit evaporates refrigerant in a coil, absorbing heat, and condenses it outside; Peltier modules move heat electrically with no refrigerant, which suits smaller chambers. A Pt100 or thermistor sensor feeds a PID controller that coordinates heating and cooling to hold the setpoint from below ambient to about 60 C, switching between modes as needed. Forced-air circulation keeps uniformity within plus or minus 0.5 to 1 C, and defrost cycles prevent ice build-up on the evaporator, which would block airflow. Chamber walls are stainless steel, and doors carry heaters or heated frames to avoid condensation at low temperature. Programmable controllers, alarms and data logging support stability and shelf-life methods.

What are the key features?

  • Multi-segment controller with 10 to 30 programs
  • Programmable ramp, hold and cool steps
  • Refrigerated cooling from 0 to 60 C
  • Data logging of temperature and humidity
  • RS-485, USB or Ethernet export
  • Scheduled defrost outside critical stages

What are the technical specifications?

A typical programmable cooled incubator configuration offers chamber volume of 50–500 L, temperature range of 0–60 C, programs of 10–30, segments per program of Up to 30, ramp rate of 0.1–5 C/min and temperature uniformity of ±0.5–1 C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Programmable Cooled Incubator is used in regulated stability studies, shelf-life testing with temperature cycles, day and night cycling for research and method transfer and validation. Across the wider Cooling Incubators class, laboratories also deploy it for enzyme and biochemical assays at low temperature, stability and shelf-life studies and sample storage and conditioning.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 9001 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the incubator where it can reject heat freely, with clearance around the condenser and vents, and avoid confined cabinets that raise ambient temperature. Keep the condenser fins clean, since dust reduces cooling and increases power use. Do not open the door at low temperature more than necessary, because ice forms on the evaporator and frames. Defrost on the recommended schedule, and drain condensate so it does not pool. Verify temperature at the working setpoint, not at a single midpoint, and calibrate with a reference probe at several positions. Check door heaters, gaskets and the refrigeration system during scheduled service, and keep records.

How do I select the right Programmable Cooled Incubator?

Select the programmable cooled incubator when methods define temperature steps, cycles or a history that must be recorded. Single-setpoint cooled units suffice for constant low-temperature work. In the RFQ, specify programs and segments, ramp range, data interface, humidity logging and defrost strategy.

How does it compare with other Cooling Incubators variants?

Choose a cooling incubator whenever the setpoint is at or below room temperature, because heating-only incubators cannot reach it, especially in warm rooms. Define the temperature range first, from a lower limit near 0 C for most units to lower values for specialized models, and decide whether you need humidity control. Select a compressor design for larger chambers and faster cooling, or Peltier for compact, quiet units without refrigerant. Match chamber volume to the load and check uniformity at the working temperature, since low-temperature operation widens gradients. Consider defrost strategy, condensation control, programmability and data logging, and confirm power, ventilation and heat rejection requirements.

Full specifications

Full specifications
Chamber volume50–500 L
Temperature range0–60 C
Programs10–30
Segments per programUp to 30
Ramp rate0.1–5 C/min
Temperature uniformity±0.5–1 C
Data interfaceRS-485, USB or Ethernet
Cooling systemCompressor
DefrostScheduled automatic
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Regulated stability studies
  • Shelf-life testing with temperature cycles
  • Day and night cycling for research
  • Method transfer and validation

Key features

  • Multi-segment controller with 10 to 30 programs
  • Programmable ramp, hold and cool steps
  • Refrigerated cooling from 0 to 60 C
  • Data logging of temperature and humidity
  • RS-485, USB or Ethernet export
  • Scheduled defrost outside critical stages

Frequently asked questions about Programmable Cooled Incubator

It can step and hold at several temperatures in sequence, ramp slowly between them and repeat the cycle, which supports day and night or accelerated shelf-life profiles. Humidity can be programmed on models that include it.

Request a quotation for the Programmable Cooled Incubator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote