Track-Connected Chemistry Workstation for Core Laboratories
面向核心实验室的轨道连接生化工作站
- SKU CHW-0005
- Chemistry Workstations
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Connection | Track divert and return modules |
|---|---|
| Throughput | 800–1400 tests/h photometric |
| Aspiration positions | 2 independent probes |
| Tube handling | Barcode read at entry and exit |
| Track speed | Up to 1000 tubes/h transport |
| Storage connection | Route to track archive or manual review |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI AUTO10, CLSI EP05
What is the Track-Connected Chemistry Workstation for Core Laboratories?
This workstation connects to a laboratory automation track, receiving tubes by barcode and returning them to the track after analysis. It suits core laboratories where chemistry is one discipline among several on a shared automation line.
What is the Track-Connected Chemistry Workstation for Core Laboratories?
This workstation connects to a laboratory automation track, receiving tubes by barcode and returning them to the track after analysis. It suits core laboratories where chemistry is one discipline among several on a shared automation line.
Overview
Chemistry modules are placed beside the track and connected through divert and return modules, so tubes arrive from the central sorter and leave for another discipline, a storage module or a manual review station. Barcode reading and middleware determine the route, and the workstation reports completion back to the track controller so the next destination is set automatically. Because the tube returns to the track rather than staying in the analyzer, capacity planning focuses on the number of aspiration positions and on the time a tube occupies them. Benefits include one sorting point for all disciplines, shared auditing of tube locations and reduced manual transport. The laboratory must validate the interface between the track controller and the chemistry middleware, and define what happens when either side is unavailable.
How does it work?
A chemistry workstation is defined by integration rather than by a single measurement principle. Photometric modules using interference filters or gratings measure colorimetric and enzymatic reactions, ion-selective electrode modules measure sodium, potassium, chloride and calcium, and immunoturbidimetric modules measure specific proteins from the light scattered by antigen-antibody complexes. Around these analytical modules the workstation adds pre-analytical handling such as rack loading, tube inspection with cameras for volume and hemolysis assessment, sorting to the correct module, and post-analytical storage of the tubes in a refrigerated archive. Middleware coordinates sample routing, applies reflex and rerun rules, tracks reagent inventory across modules and manages quality control in one record set. Interfaces to the laboratory information system use HL7 or ASTM, so the workstation appears to the user as one analytical unit with a single worklist.
What are the key features?
- Divert and return modules connecting the analyzer to a track
- Automatic routing to other disciplines or storage after analysis
- Completion reporting to the track controller
- Central sorting point shared with other disciplines
- Shared audit trail of tube locations
- Defined behaviour for controller or middleware unavailability
What are the technical specifications?
A typical track-connected chemistry workstation for core laboratories configuration offers connection of Track divert and return modules, throughput of 800–1400 tests/h photometric, aspiration positions of 2 independent probes, tube handling of Barcode read at entry and exit, track speed of Up to 1000 tubes/h transport and storage connection of Route to track archive or manual review. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Track-Connected Chemistry Workstation for Core Laboratories is used in core laboratory automation lines, multi-discipline consolidation projects, high-volume hospital networks and laboratories with central sorting and archiving. Across the wider Chemistry Workstations class, laboratories also deploy it for high-volume consolidated biochemistry testing, core laboratory workflows with automated sorting and multi-module specific protein and electrolyte testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI AUTO10, CLSI EP05, CLSI EP06, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
A workstation installation is a project rather than a single delivery: plan power distribution, network points, water supply and drainage, air conditioning and floor loading for every module in advance. Verify each analyzer module individually, then validate the integrated workflow for sorting accuracy, sample inspection results, middleware rules and archive retrieval. Build the reagent and consumable logistics for all modules into one inventory system, because running out of one reagent stops the affected channel without stopping the platform, which can mask the problem. Define and rehearse a partial-downtime procedure, clean sample paths and cameras daily, and monitor that middleware rules continue to match the clinical requirements after any software update.
How do I select the right Track-Connected Chemistry Workstation for Core Laboratories?
Select a track-connected workstation only when a laboratory automation line already exists or is being installed, because the benefits depend on shared sorting and transport. In the RFQ confirm the track controller protocol, divert and return module capacity, priorities for urgent tubes, and the fallback behaviour when the track or middleware is unavailable.
How does it compare with other Chemistry Workstations variants?
Decide a workstation configuration only after mapping your test menu by module and your daily tube count, because the integrated platform pays back through reduced handling and consolidated reporting rather than raw speed. Compare candidate systems by which modules can be combined, whether sorting is barcode-driven, whether tube inspection for hemolysis and icterus is included, and how much refrigerated archive capacity is offered. Check that middleware can implement your review rules and that it communicates through a single LIS connection. Confirm the space, water, drainage and power requirements of each module plus the archive, and the validation workload at installation. Ask whether the configuration can be expanded with another module later, and whether the archive can be upgraded independently of the analyzers.
Full specifications
| Connection | Track divert and return modules |
|---|---|
| Throughput | 800–1400 tests/h photometric |
| Aspiration positions | 2 independent probes |
| Tube handling | Barcode read at entry and exit |
| Track speed | Up to 1000 tubes/h transport |
| Storage connection | Route to track archive or manual review |
| Middleware functions | Routing rules, completion reporting, delta checks |
| Footprint | 3.0–4.5 m² including divert modules |
| Interfaces | LAN with HL7 or ASTM and track controller protocol |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Core laboratory automation lines
- Multi-discipline consolidation projects
- High-volume hospital networks
- Laboratories with central sorting and archiving
Key features
- Divert and return modules connecting the analyzer to a track
- Automatic routing to other disciplines or storage after analysis
- Completion reporting to the track controller
- Central sorting point shared with other disciplines
- Shared audit trail of tube locations
- Defined behaviour for controller or middleware unavailability
Frequently asked questions about Track-Connected Chemistry Workstation for Core Laboratories
Tubes already inside the analyzer are completed and reported, while tubes on the track wait for restart or are removed manually according to the downtime procedure. The laboratory should define a manual loading route so that urgent samples are not delayed during a track stoppage.
STAT tubes are identified by barcode or by a priority carrier and diverted to the analyzer ahead of routine tubes, or routed to a dedicated lane. The priority path must be tested during validation to confirm the maximum delay under realistic track loading, and turnaround time should be monitored in operation.
The analyzer usually keeps its own LIS interface through the middleware, while the track controller manages tube location and routing. Both must be coordinated so that the LIS reports a result only once, and the interface specification should state which system is responsible for which message.
After analysis the tube returns to the track and is routed to the archive module, where its position is recorded. If the archive is full or unavailable, the middleware can direct tubes to a manual holding area, and the laboratory should define a retrieval procedure for results that need repeat testing.
Usually when daily biochemistry volume exceeds about one thousand tests, when several stand-alone analyzers operate separately, or when sample sorting and archiving consume staff time. Below that volume a single benchtop analyzer with a small archive module often gives better value.
Middleware receives test orders, assigns samples to modules, applies reflex and rerun rules, applies review rules before result release, tracks reagent and consumable inventory across modules, and presents one consolidated result set to the laboratory information system through a single interface.
Most modular workstations allow later addition of an analyzer or archive module if floor space, power and water capacity were planned with spare margin. Retrofitting costs more than ordering at the start, and the interface and workflow must be revalidated, so plan the growth path during the initial site survey.