Consolidated Clinical Chemistry Workstation
综合临床生化工作站
- SKU CHW-0001
- Chemistry Workstations
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Effective throughput | 600–1200 tests/h on mixed menu |
|---|---|
| Reaction cuvettes | 180 reusable positions with automatic washing |
| Detection channels | Photometry, ISE, immunoturbidimetry |
| Wavelength range | 340–800 nm, 14 wavelengths |
| Reagent positions | 80 refrigerated positions at 4–10 °C |
| Sample volume | 1.5–35 µL per test |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI AUTO10, CLSI EP05
What is the Consolidated Clinical Chemistry Workstation?
A consolidated clinical chemistry workstation combines a high-throughput chemistry analyzer with integrated ion-selective electrode and immunoturbidimetry modules under one control system. It suits large hospital laboratories that report chemistry, electrolytes and specific proteins from a single sample on one platform.
What is the Consolidated Clinical Chemistry Workstation?
A consolidated clinical chemistry workstation combines a high-throughput chemistry analyzer with integrated ion-selective electrode and immunoturbidimetry modules under one control system. It suits large hospital laboratories that report chemistry, electrolytes and specific proteins from a single sample on one platform.
Overview
The workstation centralises several detection technologies on one instrument body. Photometric channels handle routine chemistry with a reaction rotor of 120 to 240 cuvettes, ion-selective electrodes measure sodium, potassium and chloride from the same aspiration, and turbidimetric channels quantify specific proteins such as CRP and immunoglobulins. One software manages calibration, quality control, reagent inventory and result reporting for every channel, so the laboratory has one worklist instead of three. Effective throughput on a mixed menu is typically 600 to 1200 tests per hour, lower than the sum of the individual channel rates because longer turbidimetric reactions occupy rotor positions. Onboard refrigeration, automatic dilution and rerun, and delta checks support unattended operation across a shift, and results leave through one HL7 or ASTM connection.
How does it work?
A chemistry workstation is defined by integration rather than by a single measurement principle. Photometric modules using interference filters or gratings measure colorimetric and enzymatic reactions, ion-selective electrode modules measure sodium, potassium, chloride and calcium, and immunoturbidimetric modules measure specific proteins from the light scattered by antigen-antibody complexes. Around these analytical modules the workstation adds pre-analytical handling such as rack loading, tube inspection with cameras for volume and hemolysis assessment, sorting to the correct module, and post-analytical storage of the tubes in a refrigerated archive. Middleware coordinates sample routing, applies reflex and rerun rules, tracks reagent inventory across modules and manages quality control in one record set. Interfaces to the laboratory information system use HL7 or ASTM, so the workstation appears to the user as one analytical unit with a single worklist.
What are the key features?
- Photometric, ISE and immunoturbidimetric channels under one control system
- Single worklist and result report for all channels
- Effective throughput of 600 to 1200 tests per hour on mixed menus
- Onboard refrigeration with reagent lot and expiry tracking
- Automatic dilution, rerun and delta check
- One HL7 or ASTM interface for the whole platform
What are the technical specifications?
A typical consolidated clinical chemistry workstation configuration offers effective throughput of 600–1200 tests/h on mixed menu, reaction cuvettes of 180 reusable positions with automatic washing, detection channels of Photometry, ISE, immunoturbidimetry, wavelength range of 340–800 nm, 14 wavelengths, reagent positions of 80 refrigerated positions at 4–10 °C and sample volume of 1.5–35 µL per test. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Consolidated Clinical Chemistry Workstation is used in large hospital biochemistry panels, consolidated specific protein testing, electrolyte testing with routine chemistry and reference laboratory routine workflows. Across the wider Chemistry Workstations class, laboratories also deploy it for high-volume consolidated biochemistry testing, core laboratory workflows with automated sorting and multi-module specific protein and electrolyte testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI AUTO10, CLSI EP05, CLSI EP06, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
A workstation installation is a project rather than a single delivery: plan power distribution, network points, water supply and drainage, air conditioning and floor loading for every module in advance. Verify each analyzer module individually, then validate the integrated workflow for sorting accuracy, sample inspection results, middleware rules and archive retrieval. Build the reagent and consumable logistics for all modules into one inventory system, because running out of one reagent stops the affected channel without stopping the platform, which can mask the problem. Define and rehearse a partial-downtime procedure, clean sample paths and cameras daily, and monitor that middleware rules continue to match the clinical requirements after any software update.
How do I select the right Consolidated Clinical Chemistry Workstation?
Specify this configuration when you want chemistry, electrolytes and specific proteins reported from one platform and one worklist. In the RFQ ask for effective throughput measured on a menu resembling yours, especially if turbidimetric assays form a large share, and confirm reagent positions, water consumption and the validation schedule for each channel.
How does it compare with other Chemistry Workstations variants?
Decide a workstation configuration only after mapping your test menu by module and your daily tube count, because the integrated platform pays back through reduced handling and consolidated reporting rather than raw speed. Compare candidate systems by which modules can be combined, whether sorting is barcode-driven, whether tube inspection for hemolysis and icterus is included, and how much refrigerated archive capacity is offered. Check that middleware can implement your review rules and that it communicates through a single LIS connection. Confirm the space, water, drainage and power requirements of each module plus the archive, and the validation workload at installation. Ask whether the configuration can be expanded with another module later, and whether the archive can be upgraded independently of the analyzers.
Full specifications
| Effective throughput | 600–1200 tests/h on mixed menu |
|---|---|
| Reaction cuvettes | 180 reusable positions with automatic washing |
| Detection channels | Photometry, ISE, immunoturbidimetry |
| Wavelength range | 340–800 nm, 14 wavelengths |
| Reagent positions | 80 refrigerated positions at 4–10 °C |
| Sample volume | 1.5–35 µL per test |
| Water consumption | 25–35 L/h during operation |
| Footprint | 3.0–4.0 m² including service access |
| Interfaces | LAN with HL7 or ASTM two-way communication |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Large hospital biochemistry panels
- Consolidated specific protein testing
- Electrolyte testing with routine chemistry
- Reference laboratory routine workflows
Key features
- Photometric, ISE and immunoturbidimetric channels under one control system
- Single worklist and result report for all channels
- Effective throughput of 600 to 1200 tests per hour on mixed menus
- Onboard refrigeration with reagent lot and expiry tracking
- Automatic dilution, rerun and delta check
- One HL7 or ASTM interface for the whole platform
Frequently asked questions about Consolidated Clinical Chemistry Workstation
Yes. When colorimetric, electrochemical and turbidimetric tests share one reaction rotor, longer turbidimetric reactions occupy positions and reduce the achievable rate. Ask for the throughput figure on a menu with your ratio of test types rather than the maximum quoted for fast colorimetric assays.
Yes, each channel and assay has its own calibration validity, determined by reagent stability and manufacturer instructions. The software tracks these separately within one record, so the laboratory should review calibration status by channel during daily checks rather than assuming that a valid calibration applies platform-wide.
The software schedules one aspiration per sample and distributes the required volume to each channel, or aspirates separately when the volumes differ significantly. Reaction positions are allocated to avoid reagent cross-contamination, and the whole set of results is released together or individually according to the review rules.
Plan at least twenty to thirty percent headroom above current peak demand to absorb growth, repeats and quality control. Also reserve floor space and utility capacity for one additional module, since most laboratories expand their menu or volume within the instrument's service life.
Usually when daily biochemistry volume exceeds about one thousand tests, when several stand-alone analyzers operate separately, or when sample sorting and archiving consume staff time. Below that volume a single benchtop analyzer with a small archive module often gives better value.
Middleware receives test orders, assigns samples to modules, applies reflex and rerun rules, applies review rules before result release, tracks reagent and consumable inventory across modules, and presents one consolidated result set to the laboratory information system through a single interface.
Most modular workstations allow later addition of an analyzer or archive module if floor space, power and water capacity were planned with spare margin. Retrofitting costs more than ordering at the start, and the interface and workflow must be revalidated, so plan the growth path during the initial site survey.