Darkfield Microscope
暗场显微镜
- SKU BIM-0005
- Biological Microscopes
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–1000× |
| Objectives | 10×, 40×, 100× plan |
| Eyepiece | 10× widefield binocular |
| Condenser | Darkfield NA 1.2–1.4, oil |
| Stage | Mechanical, 140 × 140 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8036, ISO 19012-1, ISO 9345-1
What is the Darkfield Microscope?
A darkfield microscope illuminates the specimen obliquely so that only scattered light reaches the objective, showing bright objects on a dark background. It is used for live spirochaetes, unstained cells and fine particles.
What is the Darkfield Microscope?
A darkfield microscope illuminates the specimen obliquely so that only scattered light reaches the objective, showing bright objects on a dark background. It is used for live spirochaetes, unstained cells and fine particles.
Overview
A darkfield microscope uses a special condenser that directs a hollow cone of light past the specimen at an angle too steep for direct light to enter the objective. Only light scattered by the specimen is collected, so objects appear bright against a black background. This gives high contrast for very fine or transparent structures and avoids stains that might alter fragile organisms. Darkfield suits live spirochaetes, motile microorganisms, platelets and submicron particles, and it also increases the visibility of edge detail. Careful centring of the condenser and clean slides are essential, since dust and scratches scatter light and create false bright spots.
How does it work?
A biological microscope transmits light from a source through a condenser, the specimen and the objective, then to the eyepiece or camera. The condenser focuses light onto the specimen and, with Köhler alignment, provides even illumination. The objective forms a magnified image whose resolution is limited by its numerical aperture and the light wavelength. A rotating nosepiece brings different objectives into the optical path, and the stage moves the specimen precisely in two axes. Brightfield shows absorption contrast, while phase contrast and darkfield convert refractive index differences into visible contrast for transparent specimens. Focus is adjusted by coarse and fine controls, and total magnification is the product of objective and eyepiece or camera magnification.
What are the key features?
- Darkfield condenser for oblique hollow-cone illumination
- High contrast for unstained and transparent specimens
- Bright objects on a dark background
- Effective for fine particles and motile organisms
- No staining required, preserving living specimens
What are the technical specifications?
A typical darkfield microscope configuration offers optical system of Infinite corrected, magnification range of 40×–1000×, objectives of 10×, 40×, 100× plan, eyepiece of 10× widefield binocular, condenser of Darkfield NA 1.2–1.4, oil and stage of Mechanical, 140 × 140 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Darkfield Microscope is used in live spirochaete and microorganism examination, platelet and cell counting, submicron particle detection and unstained urine sediment analysis. Across the wider Biological Microscopes class, laboratories also deploy it for clinical cytology and histology, microbiology culture examination and cell and tissue culture research.
Which standards and certifications apply?
Relevant standards and methods include ISO 8036, ISO 19012-1, ISO 9345-1, ISO 8255-1 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Set up Köhler illumination before critical observation so that illumination is even and the numerical aperture of the condenser matches the objective. Keep optics clean with a blower and lens tissue, and avoid solvents on coatings. Use the correct immersion oil with high-numerical-aperture objectives and clean it off after use. Calibrate measurements with a stage micrometer for each objective and camera combination, and record the scale. Store the microscope under a dust cover, and service the focus and stage mechanisms on the schedule recommended by the manufacturer.
How do I select the right Darkfield Microscope?
Choose a darkfield microscope for transparent or unstained specimens, especially fine or motile organisms and particles. Confirm the darkfield condenser matches the objective numerical apertures in use, and that centring controls allow correct alignment. For the smallest objects, oil darkfield condensers and clean slides are essential to avoid scattering artefacts.
How does it compare with other Biological Microscopes variants?
Choose a biological microscope for transparent or thinly sectioned specimens in transmitted light. Decide on the observation head first: a monocular head suits basic student use, a binocular head suits routine examination with comfortable viewing, and a trinocular head adds a camera port for documentation. Then select objectives and numerical aperture for the detail required, and add phase contrast or darkfield when unstained living specimens must be examined. Confirm the stage travel, condenser type and illumination source, and whether the eyepieces and objectives match the required field of view. For regulated work, verify measurement calibration and image data handling.
Full specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–1000× |
| Objectives | 10×, 40×, 100× plan |
| Eyepiece | 10× widefield binocular |
| Condenser | Darkfield NA 1.2–1.4, oil |
| Stage | Mechanical, 140 × 140 mm |
| Illumination | 3 W LED, brightness adjustable |
| Centring | Adjustable condenser centring |
| Focus adjustment | Coarse and fine |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Live spirochaete and microorganism examination
- Platelet and cell counting
- Submicron particle detection
- Unstained urine sediment analysis
Key features
- Darkfield condenser for oblique hollow-cone illumination
- High contrast for unstained and transparent specimens
- Bright objects on a dark background
- Effective for fine particles and motile organisms
- No staining required, preserving living specimens
Frequently asked questions about Darkfield Microscope
In brightfield, direct light passes through the specimen into the objective so absorbing structures appear dark on a bright background. In darkfield, direct light is blocked from the objective and only scattered light is collected, so structures appear bright on a black background, giving high contrast for fine features.
Dust, fibres and scratches scatter light and appear as bright specks on the dark background, which can be mistaken for the specimen. Using clean slides and coverslips, and cleaning the condenser and optics, keeps false signals to a minimum and preserves the high contrast of the method.
Yes. A dedicated darkfield condenser, or a brightfield condenser fitted with a darkfield stop, creates the hollow light cone. For high numerical aperture objectives, an oil darkfield condenser is needed so that the cone angle exceeds the objective aperture.
A monocular head has a single eyepiece and is economical for teaching. A binocular head has two eyepieces for comfortable routine viewing. A trinocular head adds a third port for a camera, so it is preferred when images must be captured or shared.
Phase contrast is used to view transparent, unstained specimens such as living cells and microorganisms, which show little contrast in brightfield. It converts differences in refractive index into brightness differences, making outlines and internal structures visible without staining or fixation.
Immersion oil has a refractive index close to that of glass and is placed between the specimen coverslip and a high-numerical-aperture objective. It prevents light loss at the air gap, allowing the objective to reach its rated numerical aperture and resolution. It must be cleaned off after use.
Related models