Monocular Biological Microscope
单目生物显微镜
- SKU BIM-0001
- Biological Microscopes
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–1000× |
| Objectives | 4×, 10×, 40×, 100× oil |
| Eyepiece | 10× monocular |
| Stage | Mechanical, 120 × 120 mm |
| Illumination | 3 W LED, adjustable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8036, ISO 19012-1, ISO 9345-1
What is the Monocular Biological Microscope?
A monocular biological microscope has a single eyepiece and provides basic transmitted-light observation at low cost. It is widely used for teaching, routine smears and entry-level examination where a simple optical path is sufficient.
What is the Monocular Biological Microscope?
A monocular biological microscope has a single eyepiece and provides basic transmitted-light observation at low cost. It is widely used for teaching, routine smears and entry-level examination where a simple optical path is sufficient.
Overview
A monocular biological microscope uses a single eyepiece mounted above a rotating objective nosepiece. The simple optical path keeps the instrument economical and easy to align, while coarse and fine focus controls let the operator find and hold the specimen sharply. An Abbe condenser and adjustable iris control illumination, and a mechanical stage allows precise positioning. Achromatic objectives covering 4× to 100× provide the magnifications needed for smears, cultures and sections, and a 100× oil objective reaches higher resolution. The design suits teaching laboratories and basic clinical screening, where durability and low cost are important.
How does it work?
A biological microscope transmits light from a source through a condenser, the specimen and the objective, then to the eyepiece or camera. The condenser focuses light onto the specimen and, with Köhler alignment, provides even illumination. The objective forms a magnified image whose resolution is limited by its numerical aperture and the light wavelength. A rotating nosepiece brings different objectives into the optical path, and the stage moves the specimen precisely in two axes. Brightfield shows absorption contrast, while phase contrast and darkfield convert refractive index differences into visible contrast for transparent specimens. Focus is adjusted by coarse and fine controls, and total magnification is the product of objective and eyepiece or camera magnification.
What are the key features?
- Single eyepiece for economical transmitted-light observation
- Achromatic objectives from 4× to 100× oil
- Abbe condenser with adjustable iris diaphragm
- Coarse and fine coaxial focus controls
- Mechanical stage for precise specimen positioning
What are the technical specifications?
A typical monocular biological microscope configuration offers optical system of Infinite corrected, magnification range of 40×–1000×, objectives of 4×, 10×, 40×, 100× oil, eyepiece of 10× monocular, stage of Mechanical, 120 × 120 mm and illumination of 3 W LED, adjustable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Monocular Biological Microscope is used in teaching and student laboratories, routine blood and smear examination, basic microbiology screening and water and sediment examination. Across the wider Biological Microscopes class, laboratories also deploy it for clinical cytology and histology, microbiology culture examination and cell and tissue culture research.
Which standards and certifications apply?
Relevant standards and methods include ISO 8036, ISO 19012-1, ISO 9345-1, ISO 8255-1 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Set up Köhler illumination before critical observation so that illumination is even and the numerical aperture of the condenser matches the objective. Keep optics clean with a blower and lens tissue, and avoid solvents on coatings. Use the correct immersion oil with high-numerical-aperture objectives and clean it off after use. Calibrate measurements with a stage micrometer for each objective and camera combination, and record the scale. Store the microscope under a dust cover, and service the focus and stage mechanisms on the schedule recommended by the manufacturer.
How do I select the right Monocular Biological Microscope?
Choose a monocular microscope for teaching and basic examination where cost and simplicity matter. Confirm that the objectives cover the magnifications required and that the stage and focus controls are smooth and durable. For frequent viewing or camera attachment, a binocular or trinocular head is more comfortable and versatile.
How does it compare with other Biological Microscopes variants?
Choose a biological microscope for transparent or thinly sectioned specimens in transmitted light. Decide on the observation head first: a monocular head suits basic student use, a binocular head suits routine examination with comfortable viewing, and a trinocular head adds a camera port for documentation. Then select objectives and numerical aperture for the detail required, and add phase contrast or darkfield when unstained living specimens must be examined. Confirm the stage travel, condenser type and illumination source, and whether the eyepieces and objectives match the required field of view. For regulated work, verify measurement calibration and image data handling.
Full specifications
| Optical system | Infinite corrected |
|---|---|
| Magnification range | 40×–1000× |
| Objectives | 4×, 10×, 40×, 100× oil |
| Eyepiece | 10× monocular |
| Stage | Mechanical, 120 × 120 mm |
| Illumination | 3 W LED, adjustable |
| Condenser | Abbe NA 1.25 |
| Focus adjustment | Coarse and fine, 0.002 mm |
| Nosepiece | 4-position |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Teaching and student laboratories
- Routine blood and smear examination
- Basic microbiology screening
- Water and sediment examination
Key features
- Single eyepiece for economical transmitted-light observation
- Achromatic objectives from 4× to 100× oil
- Abbe condenser with adjustable iris diaphragm
- Coarse and fine coaxial focus controls
- Mechanical stage for precise specimen positioning
Frequently asked questions about Monocular Biological Microscope
Prolonged viewing through a single eyepiece causes eye strain, so monocular instruments are best for intermittent or instructional use. Users who examine many specimens should choose a binocular head for comfortable two-eyed viewing, even at similar optical quality.
With 10× eyepieces and 4×, 10×, 40× and 100× objectives, a monocular microscope gives total magnifications of 40×, 100×, 400× and 1000×. The 1000× setting uses oil immersion and gives the highest resolution for fine detail.
Generally not without an adapter or a dual-head arrangement, because the single eyepiece is designed for direct viewing. To capture images easily, a trinocular head with a dedicated camera port is recommended instead of forcing a camera onto a monocular design.
A monocular head has a single eyepiece and is economical for teaching. A binocular head has two eyepieces for comfortable routine viewing. A trinocular head adds a third port for a camera, so it is preferred when images must be captured or shared.
Phase contrast is used to view transparent, unstained specimens such as living cells and microorganisms, which show little contrast in brightfield. It converts differences in refractive index into brightness differences, making outlines and internal structures visible without staining or fixation.
Immersion oil has a refractive index close to that of glass and is placed between the specimen coverslip and a high-numerical-aperture objective. It prevents light loss at the air gap, allowing the objective to reach its rated numerical aperture and resolution. It must be cleaned off after use.