Benchtop XRF Spectrometer for RoHS Screening
RoHS 筛查台式 XRF 光谱仪
- SKU BEX-0003
- Benchtop XRF
- CE (to be confirmed)
- Radiation safety enclosure (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Element range | Mg to U plus bromine |
|---|---|
| Detection limit | 5–100 mg/kg typical |
| Spot size | 1–8 mm with collimators |
| Measurement time | 30–300 s |
| Detector | silicon drift detector |
| Calibrations | polymer, solder, metal, film |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1621 Wavelength dispersive X-ray fluorescence, IEC 62321 Determination of restricted substances in electrotechnical products, ISO 3497 Metallic coatings — X-ray spectrometric thickness
What is the Benchtop XRF Spectrometer for RoHS Screening?
This benchtop XRF spectrometer is configured for routine RoHS and restricted substance screening. It is chosen for laboratories, manufacturers and importers that test components, electronic assemblies, plastics and finished goods for product compliance.
What is the Benchtop XRF Spectrometer for RoHS Screening?
This benchtop XRF spectrometer is configured for routine RoHS and restricted substance screening. It is chosen for laboratories, manufacturers and importers that test components, electronic assemblies, plastics and finished goods for product compliance.
Overview
The instrument includes calibrations for lead, cadmium, mercury, chromium and bromine and applies regulatory thresholds to report pass, fail or inconclusive results. Polymer, solder, metal and thin-film calibrations account for the widely different matrices of electronic assemblies. Small spots and collimator options allow measurement of thin wires, small components and coated parts. Measurement is fast, typically 30 to 300 seconds, so many parts can be screened in a shift. Because XRF measures total chromium and total bromine, positive or inconclusive results require wet chemical confirmation for hexavalent chromium and specific brominated flame retardants. The software records part identity, result and operator for compliance documentation.
How does it work?
A modest-power X-ray tube excites the sample inside a shielded enclosure, and a detector measures the characteristic X-rays emitted by the elements present. Energy-dispersive benchtop models use a silicon drift detector and record the full spectrum simultaneously, which gives fast measurement and a compact design. Wavelength-dispersive benchtop models use analyzing crystals and give better resolution and lower detection limits at higher cost. Vacuum or helium purge extends the element range toward sodium, and filters or secondary targets reduce background. The result is processed with fundamental parameters or empirical calibrations matched to the sample matrix. Enclosed geometry and interlocks ensure that no measurable radiation escapes during normal operation, and sample changers allow unattended sequences.
What are the key features?
- Calibrations for RoHS restricted elements
- Polymer, solder, metal and thin-film methods
- Small spot and collimator options
- Fast screening of many parts per shift
- Guidance for confirmatory wet chemistry
- Compliance documentation and reporting
What are the technical specifications?
A typical benchtop xrf spectrometer for rohs screening configuration offers element range of Mg to U plus bromine, detection limit of 5–100 mg/kg typical, spot size of 1–8 mm with collimators, measurement time of 30–300 s, detector of silicon drift detector and calibrations of polymer, solder, metal, film. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop XRF Spectrometer for RoHS Screening is used in electronic component compliance testing, supplier and incoming material screening, consumer product and toy surveillance and waste electrical equipment assessment. Across the wider Benchtop XRF class, laboratories also deploy it for alloy and incoming material verification, roHS and restricted substance screening and cement, glass and ceramic analysis.
Which standards and certifications apply?
Relevant standards and methods include ASTM E1621 Wavelength dispersive X-ray fluorescence, IEC 62321 Determination of restricted substances in electrotechnical products, ISO 3497 Metallic coatings — X-ray spectrometric thickness, ASTM D4294 Sulfur in petroleum products by EDXRF, IEC 61010-2-091 and ISO/IEC 17025. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Enclosed benchtop instruments are radiation devices, so installation requires correct shielding, functional interlocks, radiation survey and operator training. Sample size and thickness must fit the enclosure and the analytical requirement, and powders are best pressed into pellets for reproducibility. Matrix-matched calibration is essential for accuracy, with drift monitored by check standards. Vacuum pumps, filters and X-ray tubes are consumable and wear items. Avoid measuring liquids in unsupported open cups, and use sample spinners or masks where the software recommends them. Keep service and calibration records, and dispose of tubes and detectors according to radiation regulations.
How do I select the right Benchtop XRF Spectrometer for RoHS Screening?
Select a RoHS-configured benchtop instrument when many parts must be screened routinely at a fixed laboratory location. Specify the regulations, limits and part sizes, and confirm that polymer and thin-film calibrations and small spots are available. Plan confirmatory chemical analysis for failures and inconclusive results.
How does it compare with other Benchtop XRF variants?
Select a benchtop XRF configuration by the element range, required detection limits and sample types. Energy-dispersive models are the most common and cost-effective for screening, alloy and material verification and multi-element quantification. Wavelength-dispersive benchtop models suit light elements and more precise analysis when space and budget allow. Add vacuum or helium purge for light elements, and choose application calibrations for RoHS, cement, polymers or catalysts. Micro-XRF versions add spatial resolution for small features and coatings. Consider sample size limits inside the enclosure, the number of sample positions, data export and regulatory methods. Confirm whether a special calibration or reference material set is needed before ordering.
Full specifications
| Element range | Mg to U plus bromine |
|---|---|
| Detection limit | 5–100 mg/kg typical |
| Spot size | 1–8 mm with collimators |
| Measurement time | 30–300 s |
| Detector | silicon drift detector |
| Calibrations | polymer, solder, metal, film |
| Threshold reporting | pass, fail or inconclusive |
| Sample changer | optional 10 to 20 positions |
| Enclosure | shielded with interlocks |
| Interface | Ethernet / USB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Electronic component compliance testing
- Supplier and incoming material screening
- Consumer product and toy surveillance
- Waste electrical equipment assessment
Key features
- Calibrations for RoHS restricted elements
- Polymer, solder, metal and thin-film methods
- Small spot and collimator options
- Fast screening of many parts per shift
- Guidance for confirmatory wet chemistry
- Compliance documentation and reporting
Frequently asked questions about Benchtop XRF Spectrometer for RoHS Screening
RoHS calibrations focus on the restricted elements and use reference materials in plastics, solders and coatings, so they account for the matrices actually encountered. They also define threshold values and reporting logic. A general multi-element calibration may not be optimized for bromine or thin plastic parts.
With a small collimator, components and features down to about one millimetre can be measured, though the measurement spot must be smaller than the feature to avoid signals from surrounding material. Very thin wires and films may need longer measurement times or a different technique.
No, XRF is a screening method. It cannot identify chemical form, so hexavalent chromium and specific brominated flame retardants need wet chemical confirmation. Where regulations accept XRF screening with defined confirmatory sampling, the instrument can support compliance decisions when procedures are documented.
The sample and primary beam are fully enclosed, and interlocks prevent operation with the lid open, so no measurable radiation escapes during normal use. Some instruments emit a small amount when the shutter opens briefly or when disabled for service. Radiation surveys and dosimetry are used where local rules require them.
Benchtop enclosures typically accept samples from a few millimetres up to about 100 to 300 millimetres across, depending on the model. Larger parts must be cut or measured with a portable analyzer. Powder cups, pressed pellets and thin films are the most common sample forms in benchtop systems.
Yes, liquids are measured in cups with thin film windows, and volatile or reactive liquids require special cups and venting. Light elements in liquids are difficult because of absorption and evaporation. Some matrices are better measured after digestion or as dried residues on a carrier.
Related models