Benchtop Energy-Dispersive XRF Spectrometer
台式能量色散 XRF 光谱仪
- SKU BEX-0001
- Benchtop XRF
- CE (to be confirmed)
- Radiation safety enclosure (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Element range | Na to U (Mg to U in air) |
|---|---|
| Detection limit | 1–100 mg/kg typical |
| X-ray tube power | 10–50 W |
| Detector | silicon drift detector |
| Measurement time | 30–300 s |
| Atmosphere | air, vacuum or helium |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1621 Wavelength dispersive X-ray fluorescence, IEC 62321 Determination of restricted substances in electrotechnical products, ISO 3497 Metallic coatings — X-ray spectrometric thickness
What is the Benchtop Energy-Dispersive XRF Spectrometer?
A benchtop energy-dispersive XRF spectrometer records the full X-ray spectrum for fast, flexible multi-element analysis. It is the standard compact laboratory instrument for a wide range of alloy verification, material screening and routine quality-control work.
What is the Benchtop Energy-Dispersive XRF Spectrometer?
A benchtop energy-dispersive XRF spectrometer records the full X-ray spectrum for fast, flexible multi-element analysis. It is the standard compact laboratory instrument for a wide range of alloy verification, material screening and routine quality-control work.
Overview
The instrument uses a low-power X-ray tube, a fixed geometry and a silicon drift detector that measures photon energies directly. Because the whole spectrum is recorded at once, a measurement typically takes 30 to 300 seconds and no analyzer crystal needs to move. Filters or secondary targets can be selected to shape the excitation and lower background. Air, vacuum or helium paths accommodate different element ranges, and a sample spinner averages inhomogeneous powders. Software applies fundamental parameters or empirical calibrations and can store many application methods. Typical detection limits are in the low to mid parts per million for many elements. The compact enclosure fits on a laboratory bench and includes interlocks for radiation safety.
How does it work?
A modest-power X-ray tube excites the sample inside a shielded enclosure, and a detector measures the characteristic X-rays emitted by the elements present. Energy-dispersive benchtop models use a silicon drift detector and record the full spectrum simultaneously, which gives fast measurement and a compact design. Wavelength-dispersive benchtop models use analyzing crystals and give better resolution and lower detection limits at higher cost. Vacuum or helium purge extends the element range toward sodium, and filters or secondary targets reduce background. The result is processed with fundamental parameters or empirical calibrations matched to the sample matrix. Enclosed geometry and interlocks ensure that no measurable radiation escapes during normal operation, and sample changers allow unattended sequences.
What are the key features?
- Silicon drift detector with full-spectrum acquisition
- Low-power tube in a compact enclosed geometry
- Filters and secondary targets for background reduction
- Air, vacuum or helium measurement paths
- Sample spinner for inhomogeneous powders
- Multiple stored application calibrations
What are the technical specifications?
A typical benchtop energy-dispersive xrf spectrometer configuration offers element range of Na to U (Mg to U in air), detection limit of 1–100 mg/kg typical, X-ray tube power of 10–50 W, detector of silicon drift detector, measurement time of 30–300 s and atmosphere of air, vacuum or helium. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Energy-Dispersive XRF Spectrometer is used in alloy and incoming material verification, environmental and geological screening, cement, minerals and glass analysis and polymer and catalyst composition. Across the wider Benchtop XRF class, laboratories also deploy it for alloy and incoming material verification, roHS and restricted substance screening and cement, glass and ceramic analysis.
Which standards and certifications apply?
Relevant standards and methods include ASTM E1621 Wavelength dispersive X-ray fluorescence, IEC 62321 Determination of restricted substances in electrotechnical products, ISO 3497 Metallic coatings — X-ray spectrometric thickness, ASTM D4294 Sulfur in petroleum products by EDXRF, IEC 61010-2-091 and ISO/IEC 17025. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Enclosed benchtop instruments are radiation devices, so installation requires correct shielding, functional interlocks, radiation survey and operator training. Sample size and thickness must fit the enclosure and the analytical requirement, and powders are best pressed into pellets for reproducibility. Matrix-matched calibration is essential for accuracy, with drift monitored by check standards. Vacuum pumps, filters and X-ray tubes are consumable and wear items. Avoid measuring liquids in unsupported open cups, and use sample spinners or masks where the software recommends them. Keep service and calibration records, and dispose of tubes and detectors according to radiation regulations.
How do I select the right Benchtop Energy-Dispersive XRF Spectrometer?
Select the energy-dispersive benchtop model for flexible multi-element analysis when low parts per million detection limits are sufficient and space is limited. Specify the element range, sample types and measurement throughput. Add vacuum or helium for light elements and confirm that calibrations exist for your matrices.
How does it compare with other Benchtop XRF variants?
Select a benchtop XRF configuration by the element range, required detection limits and sample types. Energy-dispersive models are the most common and cost-effective for screening, alloy and material verification and multi-element quantification. Wavelength-dispersive benchtop models suit light elements and more precise analysis when space and budget allow. Add vacuum or helium purge for light elements, and choose application calibrations for RoHS, cement, polymers or catalysts. Micro-XRF versions add spatial resolution for small features and coatings. Consider sample size limits inside the enclosure, the number of sample positions, data export and regulatory methods. Confirm whether a special calibration or reference material set is needed before ordering.
Full specifications
| Element range | Na to U (Mg to U in air) |
|---|---|
| Detection limit | 1–100 mg/kg typical |
| X-ray tube power | 10–50 W |
| Detector | silicon drift detector |
| Measurement time | 30–300 s |
| Atmosphere | air, vacuum or helium |
| Maximum sample size | up to 300 mm |
| Sample changer | optional 10 to 20 positions |
| Enclosure | shielded with interlocks |
| Interface | Ethernet / USB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Alloy and incoming material verification
- Environmental and geological screening
- Cement, minerals and glass analysis
- Polymer and catalyst composition
Key features
- Silicon drift detector with full-spectrum acquisition
- Low-power tube in a compact enclosed geometry
- Filters and secondary targets for background reduction
- Air, vacuum or helium measurement paths
- Sample spinner for inhomogeneous powders
- Multiple stored application calibrations
Frequently asked questions about Benchtop Energy-Dispersive XRF Spectrometer
Most benchtop units occupy roughly the footprint of a small printer to a microwave oven and weigh 30 to 80 kilograms. They need a stable bench, mains power and, for vacuum models, a small pump. This makes them suitable for laboratories without space for a floor-standing spectrometer.
Detection limits depend on the element, matrix and measurement time. Many elements reach 1 to 10 parts per million, but light elements and elements in heavy matrices are less sensitive. Longer measurement times and vacuum improve limits, while trace work at the lowest levels may need wavelength-dispersive or total reflection systems.
Benchtop instruments offer sample changers for 10 to 20 positions, allowing unattended sequences for pressed pellets, cups or small parts. Trays are removable and loaded manually. Sample changers improve throughput and reproducibility because positioning is consistent between measurements.
The sample and primary beam are fully enclosed, and interlocks prevent operation with the lid open, so no measurable radiation escapes during normal use. Some instruments emit a small amount when the shutter opens briefly or when disabled for service. Radiation surveys and dosimetry are used where local rules require them.
Benchtop enclosures typically accept samples from a few millimetres up to about 100 to 300 millimetres across, depending on the model. Larger parts must be cut or measured with a portable analyzer. Powder cups, pressed pellets and thin films are the most common sample forms in benchtop systems.
Yes, liquids are measured in cups with thin film windows, and volatile or reactive liquids require special cups and venting. Light elements in liquids are difficult because of absorption and evaporation. Some matrices are better measured after digestion or as dried residues on a carrier.