Refrigerated Benchtop Centrifuge
冷冻台式离心机
- SKU BEC-0005
- Benchtop Centrifuges
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 4,000–15,000 rpm |
|---|---|
| Maximum RCF | up to approx. 21,000 x g |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±2 °C |
| Pre-cool time to 4 °C | 10–20 min |
| Maximum capacity | 4 x 100 mL or 6 x 50 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Refrigerated Benchtop Centrifuge?
A refrigerated benchtop centrifuge combines a compressor-cooled chamber with a compact footprint, holding samples between -10 and 40 C at speeds up to 15,000 rpm. It is suited to heat-sensitive proteins, cells and blood products in research and biopharma laboratories.
What is the Refrigerated Benchtop Centrifuge?
A refrigerated benchtop centrifuge combines a compressor-cooled chamber with a compact footprint, holding samples between -10 and 40 C at speeds up to 15,000 rpm. It is suited to heat-sensitive proteins, cells and blood products in research and biopharma laboratories.
Overview
The refrigerated benchtop centrifuge adds a hermetic compressor, evaporator and temperature sensors to the benchtop format so that frictional heating during the spin does not degrade samples. Chamber temperature is set between -10 and 40 C, and pre-cooling to 4 C typically takes 10 to 20 minutes. Environmentally friendly refrigerants such as R290 or R134a are used. Top speeds of 4,000 to 15,000 rpm cover both large-tube work and microtube spins, depending on rotor selection, with about 21,000 x g possible. Steel chambers resist condensation and corrosion, and a defrost cycle prevents ice accumulation. The unit has a wider, heavier body than ambient models, about 50 to 80 kg, and needs 10 to 20 cm of rear ventilation. Temperature stability of ±2 C is typical.
How does it work?
A benchtop centrifuge accelerates a rotor with a brushless DC or induction motor inside a guarded steel or composite chamber. The centrifugal force on each particle equals mass times angular velocity squared times radius, so particles denser than the medium move outward and form a pellet while lighter components remain in the supernatant. Swing-bucket rotors place tubes horizontal during the spin, which produces a flat pellet interface and suits blood tubes and gradients. Fixed-angle rotors hold tubes at 25 to 45 degrees, shortening the sedimentation path and giving faster pelleting. A microprocessor regulates speed, time and acceleration or braking curves, with a lid lock, imbalance sensor and rotor recognition providing safety.
What are the key features?
- Hermetic compressor holds the chamber between -10 and 40 C
- Pre-cool function reaches 4 C in about 10 to 20 minutes
- Interchangeable rotors cover microtubes, conical tubes and plates
- Automatic defrost and condensation drain keep the chamber dry between runs
- Temperature display and alarms log deviations during long runs
What are the technical specifications?
A typical refrigerated benchtop centrifuge configuration offers maximum speed of 4,000–15,000 rpm, maximum RCF of up to approx. 21,000 x g, temperature range of -10 to 40 °C, temperature accuracy of ±2 °C, pre-cool time to 4 °C of 10–20 min and maximum capacity of 4 x 100 mL or 6 x 50 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Refrigerated Benchtop Centrifuge is used in protein and enzyme preparation, cell pelleting at 4 C, blood component handling and nucleic acid extraction workflows. Across the wider Benchtop Centrifuges class, laboratories also deploy it for blood serum and plasma separation, urine sediment concentration and cell washing and harvesting.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, CLSI GP44, ISO 15189 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a rigid, level bench with at least 30 cm of clearance around it, and balance tubes within the maker's tolerance, commonly 0.5 to 1 g. Verify rotor speed with a tachometer and timer accuracy during annual calibration. Clean buckets and chamber with neutral detergent, avoiding chlorides that corrode aluminum, and inspect rotors for pitting or cracks. Record rotor cycles and respect rated lifetime. Clinical users should follow CLSI guidance on specimen processing and IEC 61010-2-020 safety requirements. Keep the lid open after use to prevent condensation and odor.
How do I select the right Refrigerated Benchtop Centrifuge?
Select this variant whenever protocols specify 4 C or another controlled temperature, or when runs exceed about 15 minutes at high speed. It costs and weighs more than ambient siblings. In the RFQ, state minimum temperature and stability, rotors needed, RCF, program count, refrigerant preference and ambient room conditions.
How does it compare with other Benchtop Centrifuges variants?
Define the tube types first, since blood collection tubes, 15 mL and 50 mL conical tubes, and 96-well plates each require specific buckets or adapters. Next set the required RCF: serum separation typically needs 1,000 to 3,000 x g, while cell washing needs far less. Choose a swing-bucket rotor for clean pellets and plates, and a fixed-angle rotor when speed matters most. Consider capacity, such as 4 x 100 mL or 6 x 50 mL, programmable ramp profiles that protect fragile cells, and noise below about 60 dB for shared spaces. Add aerosol-tight lids if infectious material is handled. If samples are temperature sensitive, consider a refrigerated model instead.
Full specifications
| Maximum speed | 4,000–15,000 rpm |
|---|---|
| Maximum RCF | up to approx. 21,000 x g |
| Temperature range | -10 to 40 °C |
| Temperature accuracy | ±2 °C |
| Pre-cool time to 4 °C | 10–20 min |
| Maximum capacity | 4 x 100 mL or 6 x 50 mL |
| Refrigerant | R290 or R134a |
| Program memory | 20–99 methods |
| Noise level | ≤ 62 dB(A) |
| Power supply | 220 V, 50/60 Hz, 0.8–1.5 kW |
| Weight | approx. 50–80 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein and enzyme preparation
- Cell pelleting at 4 C
- Blood component handling
- Nucleic acid extraction workflows
Key features
- Hermetic compressor holds the chamber between -10 and 40 C
- Pre-cool function reaches 4 C in about 10 to 20 minutes
- Interchangeable rotors cover microtubes, conical tubes and plates
- Automatic defrost and condensation drain keep the chamber dry between runs
- Temperature display and alarms log deviations during long runs
Frequently asked questions about Refrigerated Benchtop Centrifuge
With the lid closed and rotor installed, pre-cooling to 4 C typically takes 10 to 20 minutes from room temperature at 25 C. Pre-cooling the rotor in a cold room or refrigerator reduces this time and improves temperature stability during the first run.
Not exactly. Chamber sensors measure air or wall temperature, while sample temperature in a spinning tube can differ by 1 to 4 C due to windage and friction at higher speeds. Validate critical protocols with a calibrated probe and adjust the setpoint accordingly.
Leave the lid open after use so condensation evaporates, and wipe the chamber dry. For extended shutdown, keep the lid ajar, empty the condensation drain and remove rotors. Turn on the unit monthly for one cooling cycle if it stays idle.
General benchtop centrifuges typically reach 4,000 to 6,000 rpm, equal to about 2,000 to 5,000 x g depending on rotor radius. High-capacity models used for blood tubes run near 4,000 rpm, while smaller multi-purpose units may reach 6,000 rpm or higher.
A swing-bucket rotor lets tubes swing to horizontal during the spin, producing a flat pellet and suiting gradients, plates and blood tubes. A fixed-angle rotor holds tubes at a constant angle, giving shorter sedimentation distance, faster pelleting and higher attainable speeds, but the pellet forms against the tube wall.
Yes, provided it has buckets or adapters for the tube diameter and length, such as 13 x 75 mm to 16 x 100 mm. Serum separator tubes typically need 1,000 to 1,300 x g for 10 minutes, but always follow the tube manufacturer's instructions and the laboratory's validated protocol.