Low-Speed Benchtop Centrifuge
低速台式离心机
- SKU BEC-0001
- Benchtop Centrifuges
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-2-020 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 4,000–5,000 rpm |
|---|---|
| Maximum RCF | 2,500–4,200 x g |
| Maximum capacity | 4 x 100 mL or 24 x 10 mL |
| Speed accuracy | ±20 rpm |
| Timer range | 1–99 min |
| Temperature control | Ambient (none) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Low-Speed Benchtop Centrifuge?
A low-speed benchtop centrifuge is a compact unit running to about 4,000 to 5,000 rpm with a swing-bucket rotor for routine work. It is the right choice for clinical serum separation, urinalysis and teaching, where high RCF and refrigeration are not needed.
What is the Low-Speed Benchtop Centrifuge?
A low-speed benchtop centrifuge is a compact unit running to about 4,000 to 5,000 rpm with a swing-bucket rotor for routine work. It is the right choice for clinical serum separation, urinalysis and teaching, where high RCF and refrigeration are not needed.
Overview
The low-speed benchtop centrifuge is the workhorse of clinical and teaching laboratories. It typically offers a maximum speed of 4,000 to 5,000 rpm, giving about 3,000 to 4,000 x g with a horizontal rotor. Capacity usually ranges from 4 to 24 blood collection tubes or 4 x 50 mL conical tubes. Timers run from 1 to 99 minutes, and analog or digital speed controls are common. The brushless motor requires little maintenance, and the lid lock prevents opening until the rotor stops. Because runs are short and speeds moderate, heat generation is low and ambient operation is acceptable for serum, plasma and urine. The design emphasizes low noise, easy cleaning and reliable balance tolerance rather than advanced programming, making it cost-effective for decentralized point-of-care and ward laboratories.
How does it work?
A benchtop centrifuge accelerates a rotor with a brushless DC or induction motor inside a guarded steel or composite chamber. The centrifugal force on each particle equals mass times angular velocity squared times radius, so particles denser than the medium move outward and form a pellet while lighter components remain in the supernatant. Swing-bucket rotors place tubes horizontal during the spin, which produces a flat pellet interface and suits blood tubes and gradients. Fixed-angle rotors hold tubes at 25 to 45 degrees, shortening the sedimentation path and giving faster pelleting. A microprocessor regulates speed, time and acceleration or braking curves, with a lid lock, imbalance sensor and rotor recognition providing safety.
What are the key features?
- Brushless motor requires minimal maintenance and runs quietly under typical loads
- Swing-bucket rotor accommodates 4 to 24 blood collection tubes per run
- Digital timer from 1 to 99 minutes with audible end-of-run alert
- Electronic lid lock prevents opening while the rotor is rotating
- Imbalance detection stops the run automatically to protect the drive
What are the technical specifications?
A typical low-speed benchtop centrifuge configuration offers maximum speed of 4,000–5,000 rpm, maximum RCF of 2,500–4,200 x g, maximum capacity of 4 x 100 mL or 24 x 10 mL, speed accuracy of ±20 rpm, timer range of 1–99 min and temperature control of Ambient (none). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Low-Speed Benchtop Centrifuge is used in serum and plasma separation in clinical labs, urine sediment preparation, teaching demonstrations and point-of-care testing. Across the wider Benchtop Centrifuges class, laboratories also deploy it for blood serum and plasma separation, urine sediment concentration and cell washing and harvesting.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, CLSI GP44, ISO 15189 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-2-020 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a rigid, level bench with at least 30 cm of clearance around it, and balance tubes within the maker's tolerance, commonly 0.5 to 1 g. Verify rotor speed with a tachometer and timer accuracy during annual calibration. Clean buckets and chamber with neutral detergent, avoiding chlorides that corrode aluminum, and inspect rotors for pitting or cracks. Record rotor cycles and respect rated lifetime. Clinical users should follow CLSI guidance on specimen processing and IEC 61010-2-020 safety requirements. Keep the lid open after use to prevent condensation and odor.
How do I select the right Low-Speed Benchtop Centrifuge?
Select the low-speed model when protocols call for 3,000 x g or less at ambient temperature and throughput is moderate. Compared with high-capacity or refrigerated siblings, it is simpler and more economical. In the RFQ, specify tube types and counts, required RCF, bucket adapters, timer range, voltage, and any requirement for aerosol-tight lids.
How does it compare with other Benchtop Centrifuges variants?
Define the tube types first, since blood collection tubes, 15 mL and 50 mL conical tubes, and 96-well plates each require specific buckets or adapters. Next set the required RCF: serum separation typically needs 1,000 to 3,000 x g, while cell washing needs far less. Choose a swing-bucket rotor for clean pellets and plates, and a fixed-angle rotor when speed matters most. Consider capacity, such as 4 x 100 mL or 6 x 50 mL, programmable ramp profiles that protect fragile cells, and noise below about 60 dB for shared spaces. Add aerosol-tight lids if infectious material is handled. If samples are temperature sensitive, consider a refrigerated model instead.
Full specifications
| Maximum speed | 4,000–5,000 rpm |
|---|---|
| Maximum RCF | 2,500–4,200 x g |
| Maximum capacity | 4 x 100 mL or 24 x 10 mL |
| Speed accuracy | ±20 rpm |
| Timer range | 1–99 min |
| Temperature control | Ambient (none) |
| Noise level | ≤ 60 dB(A) |
| Power supply | 220 V, 50/60 Hz, 200–300 W |
| Dimensions (W x D x H) | approx. 400 x 450 x 280 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Serum and plasma separation in clinical labs
- Urine sediment preparation
- Teaching demonstrations
- Point-of-care testing
Key features
- Brushless motor requires minimal maintenance and runs quietly under typical loads
- Swing-bucket rotor accommodates 4 to 24 blood collection tubes per run
- Digital timer from 1 to 99 minutes with audible end-of-run alert
- Electronic lid lock prevents opening while the rotor is rotating
- Imbalance detection stops the run automatically to protect the drive
Frequently asked questions about Low-Speed Benchtop Centrifuge
Yes. A 4,000 rpm swing-bucket model with suitable buckets handles standard vacuum blood collection tubes. Most serum separator protocols specify 1,000 to 1,300 x g for 10 to 15 minutes, which is well within the capability of this class of instrument.
Yes. Speed and timer accuracy should be verified at least annually with a calibrated tachometer and stopwatch, particularly in accredited clinical laboratories working to ISO 15189. Records should be kept, and the rotor inspected for wear at the same interval.
Yes, for pelleting cells at 200 to 500 x g it is adequate. Use sealed buckets or aerosol-tight lids, place the unit near or inside a biosafety cabinet workflow, and choose a slow-ramp profile if the cells are fragile.
General benchtop centrifuges typically reach 4,000 to 6,000 rpm, equal to about 2,000 to 5,000 x g depending on rotor radius. High-capacity models used for blood tubes run near 4,000 rpm, while smaller multi-purpose units may reach 6,000 rpm or higher.
A swing-bucket rotor lets tubes swing to horizontal during the spin, producing a flat pellet and suiting gradients, plates and blood tubes. A fixed-angle rotor holds tubes at a constant angle, giving shorter sedimentation distance, faster pelleting and higher attainable speeds, but the pellet forms against the tube wall.
Yes, provided it has buckets or adapters for the tube diameter and length, such as 13 x 75 mm to 16 x 100 mm. Serum separator tubes typically need 1,000 to 1,300 x g for 10 minutes, but always follow the tube manufacturer's instructions and the laboratory's validated protocol.
Related models