

Batch Automated Analyzer
批量自动分析仪
- SKU AUA-0004
- Automated Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Type | Batch automated analyzer |
|---|---|
| Throughput | 100–600 tests/h |
| Batch size | 20–200 samples |
| Sample volume | 5–500 µL per test |
| Calibration | Per batch or schedule |
| QC positions | User defined |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1 (safety requirements for electrical equipment), ISO 15189 (medical laboratories, quality and competence), ISO 17511 (traceability of calibrators and control materials)
What is the Batch Automated Analyzer?
A batch automated analyzer processes groups of samples for the same test efficiently. It suits laboratories running high volumes of a small number of routine assays, with simple batch scheduling and calibration per batch.
What is the Batch Automated Analyzer?
A batch automated analyzer processes groups of samples for the same test efficiently. It suits laboratories running high volumes of a small number of routine assays, with simple batch scheduling and calibration per batch.
Overview
The analyzer loads a batch of samples, applies the same method to all of them, and repeats for the next test, which simplifies scheduling and reagent use. Throughput is typically 100–600 tests per hour for the batch method, and sample and reagent volumes are comparable to other analyzers. Calibration is run once per batch or on a fixed schedule, and quality control is inserted at defined positions. Because all samples follow the same sequence, the software is simpler and method changes are quick, but flexibility is lower than for random access, so urgent single samples may have to wait for the next batch. The design suits dedicated routine testing in food, environmental, pharmaceutical and industrial laboratories, and often includes washing and incubation in a fixed cycle.
How does it work?
An automated analyzer moves samples from an autosampler into reaction or detection positions, adds reagent, incubates and measures a signal, then calculates and reports results. Sample tubes are identified by barcode, and the software maps each tube to the requested test panel. Liquid handling draws sample and reagent with syringes or pumps, mixes them in cuvettes or wells, and holds them at a controlled temperature so the reaction proceeds consistently. Detection may be photometric, turbidimetric, ion-selective, fluorescent or luminescent depending on the assay. Random-access analyzers can run different tests on different samples in any order, while batch and continuous-flow systems process similar tests together. Onboard reagents are tracked with volume and expiry data, and results are reported to the laboratory information system with quality-control flags and calibration status.
What are the key features?
- Batch loading and single-method runs
- Throughput 100–600 tests per hour
- Calibration per batch or schedule
- Quality control at set positions
- Fixed wash and incubation cycle
- Simple method editing
What are the technical specifications?
A typical batch automated analyzer configuration offers type of Batch automated analyzer, throughput of 100–600 tests/h, batch size of 20–200 samples, sample volume of 5–500 µL per test, calibration of Per batch or schedule and QC positions of User defined. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Batch Automated Analyzer is used in food and beverage testing, environmental batch analysis, industrial QC and dedicated routine assays. Across the wider Automated Analyzers class, laboratories also deploy it for clinical routine chemistry, immunoassay and hormone testing and water and environmental analysis.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1 (safety requirements for electrical equipment), ISO 15189 (medical laboratories, quality and competence), ISO 17511 (traceability of calibrators and control materials), EU IVDR (in vitro diagnostic medical devices), 21 CFR Part 11 (electronic records and signatures) and CLIA (clinical laboratory improvement requirements). Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install with adequate bench or floor space, power quality and drainage where required, and confirm room temperature stability because it affects reaction rates. Run quality control at the defined frequency and review results before releasing patient or sample results, and monitor calibration and reagent expiry. Perform daily, weekly and periodic maintenance as specified, including probe cleaning, cuvette checks and fluid replacement. Verify analyzer performance on installation, after major service and on a defined schedule, covering accuracy, precision, carry-over and linearity. Define autoverification rules carefully and review flagged results. Keep records of calibration, maintenance, quality control and software changes for audit, and train operators on error recovery and shutdown.
How do I select the right Batch Automated Analyzer?
Choose batch analysis where the same test is run on large groups and flexibility is not critical. Confirm batch size, throughput and calibration scheme. RFQ: assays, batch sizes, throughput, turnaround limits and data export needs currently.
How does it compare with other Automated Analyzers variants?
Start from the test menu, the daily and peak sample numbers, and the turnaround time required. Random-access analyzers suit mixed test menus and urgent samples, while batch analyzers suit high volumes of a few tests. Confirm the analyzer offers the assays you need, either onboard or through open channels, and check reagent stability, onboard capacity and calibration frequency. Review the sample and reagent volume per test, since these drive running cost, and check the walk-away time for unattended operation. Consider connectivity to the LIMS, quality-control handling, and whether the instrument supports reflex testing and autoverification. Confirm maintenance intervals, service response and the availability of calibrators and controls, and verify traceability of calibrators to a reference standard.
Full specifications
| Type | Batch automated analyzer |
|---|---|
| Throughput | 100–600 tests/h |
| Batch size | 20–200 samples |
| Sample volume | 5–500 µL per test |
| Calibration | Per batch or schedule |
| QC positions | User defined |
| Incubation | Fixed cycle, 37 °C |
| Detection | Photometric |
| Flexibility | Low per-sample variation |
| Data export | LIS or file export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Food and beverage testing
- Environmental batch analysis
- Industrial QC
- Dedicated routine assays
Key features
- Batch loading and single-method runs
- Throughput 100–600 tests per hour
- Calibration per batch or schedule
- Quality control at set positions
- Fixed wash and incubation cycle
- Simple method editing
Frequently asked questions about Batch Automated Analyzer
Flexibility. All samples in a batch follow the same method, so a single urgent sample may need a separate run or a different analyzer if a rapid result is required.
Typically once per batch or on a fixed time schedule, and after reagent lot changes or maintenance. Frequency is set by the method, the reagent stability and the laboratory's quality system.
Yes, quality control samples are placed at defined positions in the batch, usually at the start, middle and end. Results must be in range before the batch results are reported.
An instrument that automatically handles samples and reagents, performs reactions and detection, calculates results and reports them to the laboratory information system. It runs more tests with less manual work and better consistency.
When samples need a mixed test menu, urgent results or continuous loading. Random-access analyzers can run different tests on different samples in any order, whereas batch systems process similar tests together.
By accuracy, precision, linearity, carry-over and calibration checks using certified materials, at installation and on a defined schedule. Results are compared with acceptance criteria before the analyzer is used for reporting.
Related models






