Bench-Top Automated Analyzer — product photo

Bench-Top Automated Analyzer

台式自动分析仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
TypeBench-top automated analyzer
Throughput100–400 tests/h
Sample positions20–60
Onboard assays10–30
Sample volume2–20 µL per test
Reagent volume100–300 µL per test
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1 (safety requirements for electrical equipment), ISO 15189 (medical laboratories, quality and competence), ISO 17511 (traceability of calibrators and control materials)

What is the Bench-Top Automated Analyzer?

A bench-top automated analyzer fits on a laboratory bench and runs a moderate test menu with onboard reagent and sample handling. It suits clinics and smaller laboratories with limited space, with integrated calibration and quality control.

What is the Bench-Top Automated Analyzer?

A bench-top automated analyzer fits on a laboratory bench and runs a moderate test menu with onboard reagent and sample handling. It suits clinics and smaller laboratories with limited space, with integrated calibration and quality control.

Overview

The analyzer occupies about 0.6–1.2 m of bench, with an autosampler for 20–60 samples, onboard reagents for 10–30 assays and one or two reaction or detection units. Throughput is typically 100–400 tests per hour, with photometric and sometimes ion-selective detection. Sample volumes of 2–20 µL and reagent volumes of 100–300 µL per test keep running cost moderate, and the software handles calibration, quality control and result reporting to the LIS. Consumables, waste and wash solutions are contained in accessible compartments, and daily maintenance is usually a short rinse and check. The analyzer suits clinics, veterinary laboratories and small hospital or research laboratories that need reliable routine testing without the footprint of a floor-standing line.

How does it work?

An automated analyzer moves samples from an autosampler into reaction or detection positions, adds reagent, incubates and measures a signal, then calculates and reports results. Sample tubes are identified by barcode, and the software maps each tube to the requested test panel. Liquid handling draws sample and reagent with syringes or pumps, mixes them in cuvettes or wells, and holds them at a controlled temperature so the reaction proceeds consistently. Detection may be photometric, turbidimetric, ion-selective, fluorescent or luminescent depending on the assay. Random-access analyzers can run different tests on different samples in any order, while batch and continuous-flow systems process similar tests together. Onboard reagents are tracked with volume and expiry data, and results are reported to the laboratory information system with quality-control flags and calibration status.

What are the key features?

  • Bench footprint 0.6–1.2 m
  • Autosampler for 20–60 samples
  • Onboard reagents for 10–30 assays
  • Throughput 100–400 tests per hour
  • Photometric and ISE detection
  • Onboard calibration and QC

What are the technical specifications?

A typical bench-top automated analyzer configuration offers type of Bench-top automated analyzer, throughput of 100–400 tests/h, sample positions of 20–60, onboard assays of 10–30, sample volume of 2–20 µL per test and reagent volume of 100–300 µL per test. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Bench-Top Automated Analyzer is used in clinic routine testing, veterinary diagnostics, small hospital laboratories and research routine assays. Across the wider Automated Analyzers class, laboratories also deploy it for clinical routine chemistry, immunoassay and hormone testing and water and environmental analysis.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1 (safety requirements for electrical equipment), ISO 15189 (medical laboratories, quality and competence), ISO 17511 (traceability of calibrators and control materials), EU IVDR (in vitro diagnostic medical devices), 21 CFR Part 11 (electronic records and signatures) and CLIA (clinical laboratory improvement requirements). Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install with adequate bench or floor space, power quality and drainage where required, and confirm room temperature stability because it affects reaction rates. Run quality control at the defined frequency and review results before releasing patient or sample results, and monitor calibration and reagent expiry. Perform daily, weekly and periodic maintenance as specified, including probe cleaning, cuvette checks and fluid replacement. Verify analyzer performance on installation, after major service and on a defined schedule, covering accuracy, precision, carry-over and linearity. Define autoverification rules carefully and review flagged results. Keep records of calibration, maintenance, quality control and software changes for audit, and train operators on error recovery and shutdown.

How do I select the right Bench-Top Automated Analyzer?

Choose a bench-top analyzer for moderate menus and sample numbers where space is limited. Confirm the test menu, throughput and onboard capacity. RFQ: test menu, daily samples, turnaround time, sample volume and LIS connectivity. Provide the daily and peak sample numbers.

How does it compare with other Automated Analyzers variants?

Start from the test menu, the daily and peak sample numbers, and the turnaround time required. Random-access analyzers suit mixed test menus and urgent samples, while batch analyzers suit high volumes of a few tests. Confirm the analyzer offers the assays you need, either onboard or through open channels, and check reagent stability, onboard capacity and calibration frequency. Review the sample and reagent volume per test, since these drive running cost, and check the walk-away time for unattended operation. Consider connectivity to the LIMS, quality-control handling, and whether the instrument supports reflex testing and autoverification. Confirm maintenance intervals, service response and the availability of calibrators and controls, and verify traceability of calibrators to a reference standard.

Full specifications

Full specifications
TypeBench-top automated analyzer
Throughput100–400 tests/h
Sample positions20–60
Onboard assays10–30
Sample volume2–20 µL per test
Reagent volume100–300 µL per test
DetectionPhotometric, ISE
Reaction temperature37 °C ± 0.1 °C
Footprint0.6–1.2 m bench
LIS interfaceBidirectional

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Clinic routine testing
  • Veterinary diagnostics
  • Small hospital laboratories
  • Research routine assays

Key features

  • Bench footprint 0.6–1.2 m
  • Autosampler for 20–60 samples
  • Onboard reagents for 10–30 assays
  • Throughput 100–400 tests per hour
  • Photometric and ISE detection
  • Onboard calibration and QC

Frequently asked questions about Bench-Top Automated Analyzer

Match peak load rather than the average. Estimate the busiest hour and add margin for repeats and quality control, since the analyzer also spends time on calibration, maintenance and sample loading.

Request a quotation for the Bench-Top Automated Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.