Online COD and Ammonia Nitrogen Analyzer Station — product photo

Online COD and Ammonia Nitrogen Analyzer Station

在线 COD 和氨氮分析仪监测站

  • SKU WAM-0002
  • Water Monitoring
  • CE (to be confirmed)
  • China environmental product conformity (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
COD range10–2000 mg/L, selectable sub-ranges
COD repeatability≤5%
Ammonia nitrogen range0.05–100 mg/L
Ammonia detection limit0.05 mg/L
Measurement cycle30–60 minutes
Digestion temperature165 °C for COD
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 5667-1, ISO 7027-1 (turbidity), ISO 5814 (dissolved oxygen)

What is the Online COD and Ammonia Nitrogen Analyzer Station?

A cabinet-based system that automatically samples effluent or surface water and measures chemical oxygen demand, ammonia nitrogen and related parameters with reagents. It is the standard choice for regulatory discharge monitoring at wastewater treatment plants and industrial outfalls.

What is the Online COD and Ammonia Nitrogen Analyzer Station?

A cabinet-based system that automatically samples effluent or surface water and measures chemical oxygen demand, ammonia nitrogen and related parameters with reagents. It is the standard choice for regulatory discharge monitoring at wastewater treatment plants and industrial outfalls.

Overview

This station houses a pump and sample conditioning unit, one or more analyzers and a data acquisition controller inside an insulated cabinet or shelter. COD is measured by automated digestion with potassium dichromate and photometric detection, or by permanganate index where specified. Ammonia nitrogen uses salicylate or Nessler photometry, or gas-sensing electrodes. Additional modules for total phosphorus, total nitrogen, pH and flow are common. Measurement cycles of 30 to 60 minutes are typical, and automatic calibration with standard solutions and blank checks runs on a schedule. The controller records data, triggers alarms on limit exceedance and transmits results to the environmental authority, often using the HJ 212 protocol. Reagent consumption and waste handling must be planned for.

How does it work?

Water monitors combine sensors with a controller and communication unit. Electrochemical sensors measure pH by glass electrode potential, conductivity by electrode cell resistance, and dissolved oxygen by optical luminescence quenching or a membrane-covered amperometric cell. Turbidity uses nephelometric scattering of light at 90 degrees, typically at 860 nm per ISO 7027. Ammonia, nitrate and fluoride use ion-selective electrodes, while COD, total phosphorus and total nitrogen analyzers automate digestion and photometric detection, often with UV absorbance at 254 nm as a proxy for organics. Multiparameter sondes integrate several sensors on one cable. Automatic cleaning with wipers or air blasts limits fouling. Data loggers record readings with time stamps, and telemetry sends results over cellular, satellite or radio links to a central platform with alarms.

What are the key features?

  • Automated digestion and photometric detection reduces manual reagent handling for COD.
  • Scheduled calibration and blank checks maintain data validity without operator presence.
  • Sample conditioning with filtration and pre-screening handles raw wastewater solids.
  • Exceedance alarms and remote access support rapid response to discharge events.
  • Data transmission over HJ 212 or Modbus TCP satisfies regulatory platform requirements.
  • Waste reagent containers with level sensors prevent uncontrolled disposal of digestion residue.

What are the technical specifications?

A typical online cod and ammonia nitrogen analyzer station configuration offers COD range of 10–2000 mg/L, selectable sub-ranges, COD repeatability of ≤5%, ammonia nitrogen range of 0.05–100 mg/L, ammonia detection limit of 0.05 mg/L, measurement cycle of 30–60 minutes and digestion temperature of 165 °C for COD. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Online COD and Ammonia Nitrogen Analyzer Station is used in wastewater treatment plant effluent, industrial discharge outfalls, surface water quality stations and municipal sewer network checks. Across the wider Water Monitoring class, laboratories also deploy it for surface water and river monitoring, wastewater effluent compliance and drinking water source protection.

Which standards and certifications apply?

Relevant standards and methods include ISO 5667-1, ISO 7027-1 (turbidity), ISO 5814 (dissolved oxygen), ISO 10523 (pH), HJ 355, HJ 377 and IEC 61010-1. Certification candidates for this model are CE, China environmental product conformity and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install sensors where flow is representative and away from dead zones, and ensure cable glands and enclosures meet the stated ingress protection. Calibrate pH with two or three buffers, dissolved oxygen in air-saturated water or at zero, and turbidity with formazin or polymer standards, following the manufacturer schedule. Cleaning intervals depend on biofouling, from weekly in warm eutrophic water to monthly in clean streams. Replace membranes, electrolytes and reagent cartridges on time, and keep maintenance logs. For regulatory use, validate data against laboratory reference results and apply quality flags. Protect telemetry equipment from lightning and confirm cellular coverage before deployment.

How do I select the right Online COD and Ammonia Nitrogen Analyzer Station?

Choose this station for legally required COD and ammonia discharge data where reagent-based accuracy, automatic calibration and remote reporting are needed. Sondes and optical sensors are cheaper but cannot give reference COD. In an RFQ, specify parameters and ranges, sample type and solids load, protocol (HJ 212 or Modbus), shelter needs and annual reagent supply.

How does it compare with other Water Monitoring variants?

Begin with the parameters required by the permit or the monitoring objective, then the deployment style. Spot checks and river surveys favor handheld meters or multiparameter sondes, while compliance monitoring of effluent needs online analyzers with automatic calibration and sample conditioning. Check measurement range and accuracy against the regulatory limits, for example ammonia nitrogen at 0.05–100 mg/L or COD up to 2000 mg/L. Consider fouling in raw wastewater, which may need ultrasonic or brush cleaning, and sensor life for consumables such as membranes and reagents. For remote locations, evaluate battery or solar power and telemetry. Confirm data protocols and calibration support, and choose IP68 or IP65 enclosures suited to immersion or outdoor cabinets.

Full specifications

Full specifications
COD range10–2000 mg/L, selectable sub-ranges
COD repeatability≤5%
Ammonia nitrogen range0.05–100 mg/L
Ammonia detection limit0.05 mg/L
Measurement cycle30–60 minutes
Digestion temperature165 °C for COD
CalibrationAutomatic, adjustable interval
Operating temperature5–40 °C (shelter)
Communication4G, RS-485, Ethernet; HJ 212
Power supply220 VAC, 50 Hz, about 1.5 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Wastewater treatment plant effluent
  • Industrial discharge outfalls
  • Surface water quality stations
  • Municipal sewer network checks

Key features

  • Automated digestion and photometric detection reduces manual reagent handling for COD.
  • Scheduled calibration and blank checks maintain data validity without operator presence.
  • Sample conditioning with filtration and pre-screening handles raw wastewater solids.
  • Exceedance alarms and remote access support rapid response to discharge events.
  • Data transmission over HJ 212 or Modbus TCP satisfies regulatory platform requirements.
  • Waste reagent containers with level sensors prevent uncontrolled disposal of digestion residue.

Frequently asked questions about Online COD and Ammonia Nitrogen Analyzer Station

With a 60-minute cycle, reagents typically last one to three months depending on reagent volume per test and the analyzer design. Waste containers fill at similar intervals and must be disposed of as chemical waste, since dichromate digestion residue contains chromium and mercury salts.

Related models

All Water Monitoring

Request a quotation for the Online COD and Ammonia Nitrogen Analyzer Station

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.