Schlenk Line Vacuum Manifold

Schlenk 线真空歧管

  • SKU VAM-0003
  • Vacuum Manifolds
  • ISO 9001 manufacturing (to be confirmed)
  • Material conformity (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Number of stations2–10
Working vacuumAbout 10–0.1 mbar
Body materialBorosilicate glass or stainless steel
Stopcock bore2–4 mm
Gas inletNitrogen or argon
TrapCold trap or solvent trap
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, ISO 21360, ISO 9001

What is the Schlenk Line Vacuum Manifold?

A Schlenk line vacuum manifold combines a vacuum tube and an inert gas tube with multiple stopcocks. It gives air-sensitive chemistry reliable vacuum and gas cycling for reactions, filtrations and solvent removal.

What is the Schlenk Line Vacuum Manifold?

A Schlenk line vacuum manifold combines a vacuum tube and an inert gas tube with multiple stopcocks. It gives air-sensitive chemistry reliable vacuum and gas cycling for reactions, filtrations and solvent removal.

Overview

The Schlenk line manifold has two parallel tubes, one connected to a vacuum pump through a trap and one connected to inert gas, usually nitrogen or argon. Stopcocks or valves attach each tube to pumping stations where flasks, condensers and filter frits are connected. A gas bubbler or oil bubbler shows that gas is flowing and prevents back-diffusion of air, and a cold trap protects the pump from solvent vapor. Designs range from a simple double-tube bench line to larger modular systems with graded scales and multiple stations, and some models add a pressure relief bubbler or vacuum gauge. Working vacuum is typically 10 to 0.1 mbar with a suitable pump. The manifold is central to organometallic, polymer and air-sensitive synthesis, where every transfer and filtration must occur under inert gas.

How does it work?

A vacuum manifold is a tube or block with one inlet for the pump and several valved outlets. Opening a valve connects that outlet to the vacuum while the others remain closed, so each station can be isolated without disturbing the rest. The manifold body must have enough internal bore that flow is not restricted, and each valve must seal reliably at the working vacuum. A gauge or regulator may be fitted to set and monitor the level. Manifolds are made from stainless steel, PTFE, polypropylene or glass depending on chemical exposure and temperature, and connections are usually hose barbs, luer fittings or flanges. Versions with a purge or vent port allow controlled release of vacuum. Because all ports share one pump, the pump flow must be sufficient for the number of stations in use at once.

What are the key features?

  • Parallel vacuum and inert gas tubes
  • Multiple stopcock stations for flasks and filters
  • Oil bubbler to show gas flow and block air
  • Cold trap between manifold and pump
  • Vacuum gauge and relief bubbler options
  • Modular designs with several work stations

What are the technical specifications?

A typical schlenk line vacuum manifold configuration offers number of stations of 2–10, working vacuum of About 10–0.1 mbar, body material of Borosilicate glass or stainless steel, stopcock bore of 2–4 mm, gas inlet of Nitrogen or argon and trap of Cold trap or solvent trap. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Schlenk Line Vacuum Manifold is used in air-sensitive synthesis, organometallic and catalyst work, inert filtration and transfer, solvent removal from sensitive compounds and polymer and material preparation. Across the wider Vacuum Manifolds class, laboratories also deploy it for multi-place vacuum filtration, solid-phase extraction and schlenk line vacuum and gas.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, ISO 21360, ISO 9001, USP <711> and GB 4793.1. Certification candidates for this model are ISO 9001 manufacturing and Material conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Check every valve for leaks at the working vacuum, because a single leaking port reduces performance at all stations. Use the correct tubing and clamps, and avoid kinking or long runs that reduce conductance. Keep manifolds clean and dry, and do not use vacuum grease where it can contaminate samples or block fine passages. Do not exceed the rated vacuum if the body is glass, and support glassware to avoid stress. For solvent work, trap vapor before it reaches the pump and route exhaust safely. Follow IEC 61010-1 for associated electrical equipment. Record the vacuum achieved at each port during commissioning, so that a blocked valve or leaking connection is noticed early.

How do I select the right Schlenk Line Vacuum Manifold?

Choose a Schlenk line when air- and moisture-sensitive chemistry requires repeated vacuum and gas cycles at multiple stations. For occasional inert work, a simple manifold with one or two ports may suffice. In the RFQ, state station count, gas type, trap needs and body material.

How does it compare with other Vacuum Manifolds variants?

Choose the number of ports from the maximum number of stations you will run at once, and check the internal bore so the last port still receives adequate vacuum. Select the body and valve materials for your solvents: PTFE and polypropylene for aggressive chemistry, stainless steel for durability and higher temperatures, and glass for visibility and inertness. Decide which connection type suits your flasks, cartridges or reactors, and whether each port needs an individual control valve or a simple on-off stopcock. Add a gauge or a regulator if the vacuum level must be set, and a vent or purge port if you need to release vacuum gradually. Confirm the pump flow rating for the total number of ports, and consider a manifold with a removable tray or rack for holding vessels.

Full specifications

Full specifications
Number of stations2–10
Working vacuumAbout 10–0.1 mbar
Body materialBorosilicate glass or stainless steel
Stopcock bore2–4 mm
Gas inletNitrogen or argon
TrapCold trap or solvent trap
BubblerOil or mercury-free design
GaugeOptional, 0–1000 mbar
MountingBench or frame mounted

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Air-sensitive synthesis
  • Organometallic and catalyst work
  • Inert filtration and transfer
  • Solvent removal from sensitive compounds
  • Polymer and material preparation

Key features

  • Parallel vacuum and inert gas tubes
  • Multiple stopcock stations for flasks and filters
  • Oil bubbler to show gas flow and block air
  • Cold trap between manifold and pump
  • Vacuum gauge and relief bubbler options
  • Modular designs with several work stations

Frequently asked questions about Schlenk Line Vacuum Manifold