Benchtop Vacuum Desiccator Chamber
台式真空干燥器
- SKU VAC-0001
- Vacuum Chambers
- ISO 9001 manufacturing (to be confirmed)
- Material conformity (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Volume | 3–30 L |
|---|---|
| Working vacuum | 100–10 mbar |
| Body material | Polycarbonate, PP or borosilicate glass |
| Seal | Soft gasket or greased joint |
| Port | Stopcock plus gauge port |
| Internal height | 150–300 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, ISO 21360, ISO 27893
What is the Benchtop Vacuum Desiccator Chamber?
A benchtop vacuum desiccator chamber is a transparent vessel for storing moisture-sensitive samples and drying them under rough vacuum. It uses a sealable lid and desiccant tray for both vacuum and ambient-preservation work.
What is the Benchtop Vacuum Desiccator Chamber?
A benchtop vacuum desiccator chamber is a transparent vessel for storing moisture-sensitive samples and drying them under rough vacuum. It uses a sealable lid and desiccant tray for both vacuum and ambient-preservation work.
Overview
The benchtop vacuum desiccator is made from polycarbonate, polypropylene or borosilicate glass, often with a clear body and a flat or domed lid. Sizes range from 3 to 30 liters, and internal shelves or trays hold samples or desiccant. A stopcock or valve connects to a vacuum pump or aspirator, and a wall port lets a gauge be fitted. The seal is a soft gasket or greased ground joint. Working vacuum is roughly 100 to 10 mbar, which is enough for drying, storage and degassing of small parts. The transparent body allows visual inspection, and the flat base sits on a bench. These chambers are widely used for keeping hygroscopic powders, electronic components and biological samples dry, and for gentle drying of delicate materials at room temperature.
How does it work?
A vacuum chamber provides the sealed volume from which a pump removes gas. Its walls and seals must resist the pressure difference, which at full vacuum is about one bar acting inward on every square centimeter. Chamber materials, usually stainless steel, aluminum, acrylic or glass, determine strength, chemical resistance and outgassing behavior. Seals in O-ring grooves, gaskets or flat flanges keep air out, and the sealing method sets the achievable vacuum and the ease of opening. Ports allow connection to a pump, gauge, vent valve and feedthroughs for electrical, fluid or optical access. Internal features such as shelves, heating platens, electrodes or sample holders adapt the chamber to its task. The pump-down rate depends on chamber volume, pump speed and the conductance of the connecting line, so the chamber and pump must be matched.
What are the key features?
- Transparent polycarbonate, PP or borosilicate glass body
- Volumes of 3–30 L with internal shelves or trays
- Stopcock or valve for pump or aspirator connection
- Working vacuum of about 100–10 mbar
- Desiccant tray for ambient moisture control
- Flat bench base with optional gauge port
What are the technical specifications?
A typical benchtop vacuum desiccator chamber configuration offers volume of 3–30 L, working vacuum of 100–10 mbar, body material of Polycarbonate, PP or borosilicate glass, seal of Soft gasket or greased joint, port of Stopcock plus gauge port and internal height of 150–300 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Vacuum Desiccator Chamber is used in moisture-sensitive sample storage, room-temperature gentle drying, degassing small parts, powder and component preservation and delicate biological sample drying. Across the wider Vacuum Chambers class, laboratories also deploy it for sample drying and desiccation, degassing of liquids and resins and vacuum coating and evaporation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, ISO 21360, ISO 27893, ISO 9001 and GB 4793.1. Certification candidates for this model are ISO 9001 manufacturing and Material conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Never use a chamber above its rated pressure difference, and fit a relief valve or rupture disc where a pump could over-pressurize it or where a process generates gas. Keep sealing surfaces clean and free of scratches, and replace O-rings that are cut, swollen or hardened. Apply vacuum grease sparingly, because excess grease traps particles and can contaminate samples. Support heavy doors safely and check hinges and clamps regularly, especially on large chambers. Verify thermal uniformity if the chamber is heated, and use compatible feedthroughs for electrical or fluid lines. Follow IEC 61010-1 for associated electrical equipment and local pressure vessel rules where applicable. Record base pressure and leak-up rate during commissioning so changes can be detected later.
How do I select the right Benchtop Vacuum Desiccator Chamber?
Choose a desiccator chamber for storage and gentle drying at rough vacuum, where transparency and low cost matter. For heated drying or deep vacuum, choose an oven or stainless chamber. In the RFQ, state volume, material, vacuum level and accessories.
How does it compare with other Vacuum Chambers variants?
Start with the volume needed for your samples or components, and the pressure you must reach. A desiccator-style chamber works for storage and gentle drying at rough vacuum, while ovens and coating chambers need deeper vacuum and often heating or electrode feedthroughs. Choose the material for the process: stainless steel for strength, chemical resistance and cleanability; acrylic or glass for visibility and non-magnetic work; aluminum for light weight. Confirm the pressure rating with a safety factor and check whether a relief device is needed. Select the sealing method, typically an O-ring or gasket, for the vacuum level and opening frequency, and list the ports you need for pump, gauge, vent and feedthroughs. Consider internal fixtures, door or lid access, window size and how the chamber will be cleaned and mounted.
Full specifications
| Volume | 3–30 L |
|---|---|
| Working vacuum | 100–10 mbar |
| Body material | Polycarbonate, PP or borosilicate glass |
| Seal | Soft gasket or greased joint |
| Port | Stopcock plus gauge port |
| Internal height | 150–300 mm |
| Max temperature | 60 °C for plastic, 120 °C for glass |
| Desiccant tray | Included |
| Weight | 1–6 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Moisture-sensitive sample storage
- Room-temperature gentle drying
- Degassing small parts
- Powder and component preservation
- Delicate biological sample drying
Key features
- Transparent polycarbonate, PP or borosilicate glass body
- Volumes of 3–30 L with internal shelves or trays
- Stopcock or valve for pump or aspirator connection
- Working vacuum of about 100–10 mbar
- Desiccant tray for ambient moisture control
- Flat bench base with optional gauge port
Frequently asked questions about Benchtop Vacuum Desiccator Chamber
Yes, with fresh desiccant the chamber keeps humidity low at ambient pressure. Apply vacuum briefly to remove air and moisture, then close the valve for storage.
Plastic bodies suit rough vacuum and are safer than glass if they fail, since they do not shatter. Glass offers better visibility and higher temperature tolerance but must be handled carefully.
Clean the mating surfaces, replace hardened or cut gaskets, and apply a thin film of vacuum grease to ground joints. A leak-up test with the valve closed shows whether the seal needs attention.
It depends on the material, wall thickness and design, but the limit is the pressure difference it can safely withstand, normally about one bar for a sealed vessel evacuated to rough vacuum. Follow the manufacturer rating on the label.
Stainless steel for strength, chemical resistance and cleanability; acrylic or glass for visibility and non-magnetic use; aluminum to save weight. Match the material to your samples and cleaning agents.
Common causes are a dirty or damaged O-ring, a loose flange, a poor hose connection or trapped solvent. Clean and reseal, check every joint and measure the leak-up rate with the pump isolated.
Related models